Based on changes in the power source voltage, the main body ECU (multiplex network body ECU) can detect if the battery has been disconnected and reconnected.
Before replacing the main body ECU (multiplex network body ECU), refer to Service Bulletin.
Inspect the fuses for circuits related to this system before performing the following procedure.
Disconnect the 3F instrument panel junction block assembly connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3F-1 - Body ground | Always | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the main body ECU (multiplex network body ECU).
for LHD: Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for LHD)>REMOVAL
for RHD: Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for RHD)>REMOVAL
| *a | Component without harness connected
(Instrument Panel Junction Block Assembly) |
- | - |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3F-1 - MB-31 (BECU) | Always | Below 1 Ω |
| Result | Proceed to |
|---|---|
| OK (for LHD) | A |
| OK (for RHD) | B |
| NG (for LHD) | C |
| NG (for RHD) | D |
A
B
C
D