The main body ECU (multiplex network body ECU) controls operation of the DOME CUT relay in order to supply power to the interior lights. When the battery saving function operates while the interior lights are on, the main body ECU (multiplex network body ECU) opens the DOME CUT relay to turn off the lights.
Inspect the fuses for circuits related to this system before performing the following procedure.
Before replacing the main body ECU (multiplex network body ECU), refer to Service Bulletin*1.
*1: w/ Entry and Start System
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Main Body / Active Test.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Relay for Interior Light Auto Cut Function | DOME CUT relay | ON or OFF | When performing this active test, turn all the interior lights on.
·
ON: DOME CUT relay off (interior lights turn off) ·
OFF: DOME CUT relay on (interior lights turn on) |
| Tester Display |
|---|
| Relay for Interior Light Auto Cut Function |
All of the interior lights turn off when ON is selected.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the 3K instrument panel junction block assembly connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3K-1 - Body ground | Always | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the instrument panel junction block assembly.
for LHD: Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for LHD)>REMOVAL
for RHD: Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for RHD)>REMOVAL
Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
for LHD: Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for LHD)>REMOVAL
for RHD: Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for RHD)>REMOVAL
Measure the voltage and resistance according to the value(s) in the table below.
| *a | Component without harness connected
(Instrument Panel Junction Block Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3H-19 - Battery negative terminal | Battery positive (+) → 3K-1
Battery negative (-) → MB-23 (DOMR) |
11 to 14 V |
| 3D-9 - Battery negative terminal | Battery positive (+) → 3K-1
Battery negative (-) → MB-23 (DOMR) |
11 to 14 V |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3K-1 - 3H-19 | Always | 10 kΩ or higher |
| 3K-1 - 3D-9 | Always | 10 kΩ or higher |
| Result | Proceed to |
|---|---|
| OK (for LHD) | A |
| OK (for RHD) | B |
| NG (for LHD) | C |
| NG (for RHD) | D |
A
B
C
D