The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed, installed, or replaced during the blower unit removal/installation are shown below.
*1: When performing learning using the GTS.
1. PRECAUTION
Make sure to perform initialization after replacing the No. 1 blower damper servo sub-assembly. If initialization is not performed, the air conditioner unit assembly will not perform properly as the air conditioning amplifier assembly will not be able to recognize the position of the No. 1 blower damper servo sub-assembly.
2.REMOVE AIR CONDITIONER UNIT ASSEMBLY
87211
3.REMOVE NO. 1 AIR DUCT
87130D
4.REMOVE BLOWER ASSEMBLY
Disconnect the connector.
Disengage the guides.
Remove the 2 screws.
Disengage the claws and guides to remove the blower assembly from the air conditioning radiator assembly.