Home › Power Source / Network › 3ZR-FAE (BATTERY / CHARGING) › GENERATOR › 2019.09–2020.08
RM32H0E _57 Power Source / Network _060210 3ZR-FAE BATTERY / CHARGING _0295253 GENERATOR A

3ZR-FAE BATTERY / CHARGING  GENERATOR  REMOVAL  


CAUTION / NOTICE / HINT

The necessary procedures(adjustment, calibration, initialization, or registration) that must be performed after parts are removed, installed, or replaced during the generator assembly removal/installation are shown below.

Necessary Procedure After Parts Removed/Installed/Replaced
Replacement Part or Procedure Necessary Procedure Effect/Inoperative when not Performed Link

*1: When performing learning using the GTS.

Click here(Click here)

Disconnect cable from negative battery terminal Perform steering sensor zero point calibration Toyota parking assist-sensor system*1 (Click here)
Simple intelligent parking assist system*1
Initialize back door lock Power door lock control system (Click here)

PROCEDURE

Hide 1. PRECAUTION

NOTICE:

After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


Hide 2.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

Click hereGeneral>MAINTENANCE>3ZR-FAE BATTERY>REMOVAL

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION


Hide 3.REMOVE FAN AND GENERATOR V BELT

Hide 27020 4.REMOVE GENERATOR ASSEMBLY

a.
A392505

Remove the terminal cap from the generator assembly.


b.

Remove the nut to disconnect the engine wire from terminal B.


c.

Disconnect the generator assembly connector.


d.

Disengage the clamp to disconnect the wire harness from the wire harness clamp bracket.


e.
A392506

Remove the 2 bolts and generator assembly.


f.
A392507

Remove the bolt and wire harness clamp bracket from the generator assembly.