When the cable is disconnected / reconnected to the battery terminal, systems temporarily stop operating. However, each system has a function that completes learning the first time the system is used.
Learning completes when vehicle is operated normally
1. PRECAUTION
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
2.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
3.REMOVE FAN AND GENERATOR V BELT
27020
4.REMOVE GENERATOR ASSEMBLY
Remove the terminal cap from the generator assembly.
Remove the nut to disconnect the engine wire from terminal B.
Disconnect the generator assembly connector.
Disengage the clamp to disconnect the wire harness from the wire harness clamp bracket.
Remove the 2 bolts and generator assembly.
Remove the bolt and wire harness clamp bracket from the generator assembly.