2006-2011 Camry Aurion · Service Manual TRANSMISSION

P0710 Transmission Fluid Temperature Sensor "A" Circuit

Diagnostic trouble codes · Vehicles built from Oct 2006

Also covers:

DESCRIPTION

The ATF (Automatic Transmission Fluid) temperature sensor converts the fluid temperature into a resistance value for use by the TCM.
G031389E14
The TCM applies a voltage to the temperature sensor through terminal THO1 of the TCM.
The sensor resistance changes with the transmission fluid temperature. As the temperature becomes higher, the sensor resistance decreases.
One terminal of the sensor is grounded so that the sensor resistance decreases and the voltage goes down as the temperature becomes higher.
The TCM calculates the fluid temperature based on the voltage signal.
DTC No.
DTC Detection Condition
Trouble Area
P0710
(a) and (b) are detected momentarily (within 0.5 sec.) when neither P0712 nor P0713 is detected (1-trip detection logic).
(a) ATF temperature sensor resistance is less than 79 Ω.
(b) ATF temperature sensor resistance is more than 156 kΩ.

HINT:
Within 0.5 sec., the malfunction switches from (a) to (b) or from (b) to (a).

  1. Open or short in ATF temperature sensor circuit
  2. Transmission wire (ATF temperature sensor)
  3. TCM
P0712
ATF temperature sensor resistance is less than 79 Ω for 0.5 sec. or more (1-trip detection logic).
  1. Short in ATF temperature sensor circuit
  2. Transmission wire (ATF temperature sensor)
  3. TCM
P0713
ATF temperature sensor resistance is more than 156 kΩ when 15 minutes or more have elapsed after the engine starts.
DTC is detected for 0.5 sec. or more (1-trip detection logic).
  1. Open in ATF temperature sensor circuit
  2. Transmission wire (ATF temperature sensor)
  3. TCM

MONITOR DESCRIPTION

These DTCs indicate an open or short in the automatic transmission fluid (ATF) temperature sensor (TFT sensor) circuit. The automatic transmission fluid (ATF) temperature sensor converts ATF temperature into an electrical resistance value. Based on the resistance, the TCM determines the ATF temperature, and the TCM detects an open or short in the ATF temperature circuit. If the resistance value of the ATF temperature is less than 79 Ω*1 or more than 156 kΩ*2, the TCM interprets this as a fault in the ATF sensor or wiring. The TCM will turn on the MIL and store the DTC.

HINT:
The ATF temperature can be checked on the intelligent tester display.
*1: 150°C (302°F) or more is indicated regardless of the actual ATF temperature.
*2: -40°C (-40°F) is indicated regardless of the actual ATF temperature.


WIRING DIAGRAM

C133262E02

INSPECTION PROCEDURE


DATA LIST

HINT:
According to the Data List displayed on the intelligent tester, you can read the value of switches, sensors, actuators and other items without removing any parts. Reading the Data List as the first step in troubleshooting is one method to save diagnostic time.

NOTICE:
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty.

  1. Warm up the engine.

  2. Turn the ignition switch off.

  3. Connect the intelligent tester to the DLC3.

  4. Turn the ignition switch on (IG).

  5. Turn on the tester.

  6. Enter the following items: "Powertrain / ECT / Data List".

  7. According to the display on the tester, read "Data List".

    Tester Display
    Measurement Item/Range
    Normal Condition
    A/T Oil Temperature 1
    ATF Temperature Sensor Value/
    min.: -40°C (-40°F)
    max.: 215°C (419°F)
    1. After Stall Test;
      Approx. 80°C (176°F)
    2. Equal to ambient temperature when cold soak

    HINT:
    1. When DTC P0712 is output and the intelligent tester indicates 150°C (302°F) or more, there is a short circuit.
    1. When DTC P0713 is output and the intelligent tester indicates -40°C (-40°F), there is an open circuit.
    1. Measure the resistance between terminal THO1 and body ground.

    Temperature Displayed
    Malfunction
    -40°C (-40°F)
    Open circuit
    150°C (302°F) or more
    Short circuit

    HINT:
    1. If the circuit related to the ATF temperature sensor becomes open, P0713 is immediately set (in 0.5 seconds). When P0713 is set, P0711 cannot be detected.
    1. It is not necessary to inspect the circuit when P0711 is set.


1. INSPECT TRANSMISSION WIRE (ATF TEMPERATURE SENSOR)

  1. C133212E01
    Remove the TCM from the transaxle.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Specified Condition
    17 (E2) - 18 (THO1)
    90 Ω to 156 kΩ
    17 (E2) - Body ground
    10 kΩ or higher
    18 (THO1) - Body ground
    10 kΩ or higher

    HINT:
    If the resistance is out of the specified range with the ATF temperature shown in the table below, the driveability of the vehicle may decrease.

    Standard resistance:
    ATF Temperature
    Specified Condition
    10°C (50°F)
    5.8 to 7.1 kΩ
    110°C (230°F)
    0.22 to 0.28 kΩ



OK
REPLACE TCM
NG


2. INSPECT ATF TEMPERATURE SENSOR

  1. C133224E01
    Disconnect the ATF temperature sensor connector from the transmission wire.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Specified Condition
    E2 - THO1
    90 Ω to 156 kΩ
    E2 - Body ground
    10 kΩ or higher
    THO1 - Body ground
    10 kΩ or higher

    HINT:
    If the resistance is out of the specified range with the ATF temperature shown in the table below, the driveability of the vehicle may decrease.

    Standard resistance:
    ATF Temperature
    Specified Condition
    10°C (50°F)
    5.8 to 7.1 kΩ
    110°C (230°F)
    0.22 to 0.28 kΩ



NG
REPLACE ATF TEMPERATURE SENSOR ASSEMBLY
OK

REPLACE TRANSMISSION WIRE


← P0705 Transmission Range Sensor Circuit Malfunction (PRNDL Input) (from Jun 2009)P0711 Transmission Fluid Temperature Sensor "A" Performance (from Oct 2006) →