Home › Engine / Hybrid System · 1AZ-FE › ENGINE CONTROL › SFI SYSTEM

DTC    P0136    Oxygen Sensor Circuit Malfunction (Bank 1 Sensor 2)

DTC    P0137    Oxygen Sensor Circuit Low Voltage (Bank 1 Sensor 2)

DTC    P0138    Oxygen Sensor Circuit High Voltage (Bank 1 Sensor 2)

for Preparation Click here


DESCRIPTION

In order to obtain a high purification rate of the carbon monoxide (CO), hydrocarbon (HC) and nitrogen oxide (NOx) components in the exhaust gas, a TWC (Three-Way Catalytic Converter) is used. For the most efficient use of the TWC, the air fuel ratio must be precisely controlled so that it is always close to the stoichiometric air fuel level. For the purpose of helping the ECM to deliver accurate air fuel ratio control, a heated oxygen sensor is used.
The heated oxygen sensor is located behind the TWC, and detects the oxygen concentration in the exhaust gas. Since the sensor is integrated with the heater that heats the sensing portion, it is possible to detect the oxygen concentration even when the intake air volume is low (the exhaust gas temperature is low).
When the air fuel ratio becomes lean, the oxygen concentration in the exhaust gas is high. The heated oxygen sensor informs the ECM that the post-TWC air fuel ratio is lean (low voltage, i.e. less than 0.45 V).
Conversely, when the air fuel ratio is richer than the stoichiometric air fuel level, the oxygen concentration in the exhaust gas is low. The heated oxygen sensor informs the ECM that the post-TWC air fuel ratio is rich (high voltage, i.e. more than 0.45 V). The heated oxygen sensor has the property of changing its output voltage drastically when the air fuel ratio is close to the stoichiometric level.
The ECM uses the supplementary information from the heated oxygen sensor to determine whether the air fuel ratio after the TWC is rich or lean, and adjusts the fuel injection duration accordingly. Thus, if the heated oxygen sensor is working improperly due to internal malfunctions, the ECM is unable to compensate for deviations in the primary air fuel ratio control.

A268772E01


DTC No.
DTC Detection Condition
Trouble Area
P0136
Abnormal voltage output:
During active air fuel ratio control, the following conditions (a) and (b) are met for a certain period of time (2 trip detection logic):
  1. (a) Heated oxygen sensor voltage does not increase to 0.69 V or higher.
  2. (b) Heated oxygen sensor voltage does not decrease to less than 0.21 V.
  1. Heated oxygen sensor (sensor 2) circuit
  2. Heated oxygen sensor (sensor 2)
  3. Air fuel ratio sensor (sensor 1)
  4. Gas leak from exhaust system
  5. Fuel injector assembly
  6. Fuel pressure
  7. PCV valve and hose
  8. Intake system
P0137
Low voltage (open):
During active air fuel ratio control, the following conditions (a) and (b) are met for a certain period of time (2 trip detection logic):
  1. (a) Heated oxygen sensor voltage output is less than 0.21 V.
  2. (b) Target air fuel ratio is rich.
  1. Heated oxygen sensor (sensor 2) circuit
  2. Heated oxygen sensor (sensor 2)
  3. Air fuel ratio sensor (sensor 1)
  4. Gas leak from exhaust system
P0138
High voltage (short):
During active air fuel ratio control, the following conditions (a) and (b) are met for a certain period of time (2 trip detection logic):
  1. (a) Heated oxygen sensor voltage output is higher than 0.69 V.
  2. (b) Target air fuel ratio is lean.
  1. Heated oxygen sensor (sensor 2) circuit
  2. Heated oxygen sensor (sensor 2)
  3. Air fuel ratio sensor (sensor 1)
  4. ECM

MONITOR DESCRIPTION


Active Air Fuel Ratio Control
The ECM usually performs air fuel ratio feedback control so that the air fuel ratio sensor output indicates a near stoichiometric air fuel level. This vehicle includes active air fuel ratio control in addition to regular air fuel ratio control. The ECM performs active air fuel ratio control to detect any deterioration in the Three-Way Catalytic Converter (TWC) and heated oxygen sensor malfunctions (refer to the diagram below).
Active air fuel ratio control is performed for approximately 15 to 20 seconds while driving with a warm engine. During active air fuel ratio control, the air fuel ratio is forcibly regulated to become lean or rich by the ECM. If the ECM detects a malfunction, a DTC is stored.

Abnormal Voltage Output of Heated Oxygen Sensor (DTC P0136)
While the ECM is performing active air fuel ratio control, the air fuel ratio is forcibly regulated to become rich or lean. If the sensor is not functioning properly, the voltage output variation is small. For example, when the heated oxygen sensor voltage does not decrease to less than 0.21 V and does not increase to higher than 0.69 V during active air fuel ratio control, the ECM determines that the sensor voltage output is abnormal and stores DTC P0136.

A152942E57


Open or Short in Heated Oxygen Sensor Circuit (DTC P0137 or P0138)
During active air fuel ratio control, the ECM calculates the Oxygen Storage Capacity (OSC)* of the Three-Way Catalytic Converter (TWC) by forcibly regulating the air fuel ratio to become rich or lean. If the heated oxygen sensor has an open or short circuit, or the voltage output of the sensor noticeably decreases, the OSC indicated an extraordinarily high value. Even if the ECM attempts to continue regulating the air fuel ratio to become rich or lean, the heated oxygen sensor output does not change.
While performing active air fuel ratio control, when the target air fuel ratio is rich and the heated oxygen sensor voltage output is less than 0.21 V (lean), the ECM interprets this as an abnormally low sensor output voltage and stores DTC P0137. When the target air fuel ratio is lean and the voltage output is higher than 0.69 V (rich) during active air fuel ratio control, the ECM determines that the sensor voltage output is abnormally high and stores DTC P0138.
*: The TWC has the capability to store oxygen. The OSC and the emissions purification capacity of the TWC are mutually related. The ECM determines whether the catalyst has deteriorated based on the calculated OSC value .

A152992E40


MONITOR STRATEGY


Required Sensors/Components (Main)
Heated oxygen sensor
Required Sensors/Components (Related)
Crankshaft position sensor
Engine coolant temperature sensor
Mass air flow meter sub-assembly
Throttle position sensor
Air fuel ratio sensor
Frequency of Operation
Once per driving cycle

TYPICAL ENABLING CONDITIONS


Heated Oxygen Sensor Voltage Check (Voltage Malfunction, High Voltage and Low Voltage) 
Active air fuel ratio control
Executing
Active air fuel ratio control begins when all of the following conditions are met
-
Battery voltage
11 V or higher
Engine coolant temperature
75°C (167°F) or higher
Idling
Off
Engine speed
Less than 4000 rpm
Air fuel ratio sensor status
Activated
Fuel system status
Closed loop
Engine load
10% or higher, and less than 80%

TYPICAL MALFUNCTION THRESHOLDS


P0136: Heated Oxygen Sensor Voltage Check (Voltage Malfunction) 
Either of the following conditions is met
1 or 2
1. Both of the following conditions are met
(a) and (b)
(a) Commanded air fuel ratio
14.4 or less
(b) Heated oxygen sensor voltage
0.21 V or higher, and less than 0.69 V
2. Both of the following conditions are met
(c) and (d)
(c) Commanded air fuel ratio
14.8 or more
(d) Heated oxygen sensor voltage
0.21 V or higher, and less than 0.69 V

P0137: Heated Oxygen Sensor Voltage Check (Low Voltage) 
Both of the following conditions are met
(a) and (b)
(a) Commanded air fuel ratio
14.4 or less
(b) Heated oxygen sensor voltage
Less than 0.21 V

P0138: Heated Oxygen Sensor Voltage Check (High Voltage) 
Both of the following conditions are met
(a) and (b)
(a) Commanded air fuel ratio
14.8 or more
(b) Heated oxygen sensor voltage
Higher than 0.69 V

CONFIRMATION DRIVING PATTERN

HINT:
  1. This confirmation driving pattern is used in the "Perform Confirmation Driving Pattern" procedure of the following diagnostic troubleshooting procedure.
  2. Performing this confirmation driving pattern will activate the heated oxygen sensor monitor (the catalyst monitor is performed simultaneously). This is very useful for verifying the completion of a repair.


A264212E01

  1. Connect the intelligent tester to the DLC3.
  2. Turn the ignition switch to ON and turn the tester on.
  3. Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
  4. Turn the ignition switch off and wait for at least 30 seconds.
  5. Turn the ignition switch to ON and turn the tester on [A].
  6. Start the engine and warm it up until the engine coolant temperature reaches 75°C (167°F) or higher [B].
  7. With the shift lever in D, drive the vehicle at 60 to 100 km/h (37 to 62 mph) for 10 minutes or more [C].

    CAUTION:
    When performing the confirmation driving pattern, obey all speed limits and traffic laws.

  8. Enter the following menus: Powertrain / Engine and ECT / DTC [D].
  9. Read the pending DTCs.

    HINT:
    1. If a pending DTC is output, the system is malfunctioning.
    2. If a pending DTC is not output, perform the following procedure.

  10. Enter the following menus: Powertrain / Engine and ECT / Utility / All Readiness.
  11. Input the DTC: P0136, P0137 or P0138.
  12. Check the DTC judgment result.

    Tester Display
    Description
    NORMAL
    1. DTC judgment completed
    2. System normal
    ABNORMAL
    1. DTC judgment completed
    2. System abnormal
    INCOMPLETE
    1. DTC judgment not completed
    2. Perform driving pattern after confirming DTC enabling conditions
    N/A
    1. Unable to perform DTC judgment
    2. Number of DTCs which do not fulfill DTC preconditions has reached ECU memory limit

    HINT:
    1. If the judgment result shows NORMAL, the system is normal.
    2. If the judgment result shows ABNORMAL, the system has a malfunction.
    3. If the judgment result shows INCOMPLETE or N/A, perform steps [C] and [D] again.


WIRING DIAGRAM


A266783E03


INSPECTION PROCEDURE

HINT:
Malfunctioning areas can be identified by performing the Control the Injection Volume for A/F Sensor function provided in the Active Test. The Control the Injection Volume for A/F Sensor function can help to determine whether the air fuel ratio sensor, heated oxygen sensor and other potential trouble areas are malfunctioning.
The following instructions describe how to conduct the Control the Injection Volume for A/F Sensor operation using the intelligent tester.
  1. Connect the intelligent tester to the DLC3.
  2. Start the engine.
  3. Turn the tester on.
  4. Warm up the engine and run the engine at an engine speed of 2500 rpm for approximately 90 seconds.
  5. Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Injection Volume for A/F Sensor / All Data / AFS Voltage B1S1 and O2S B1S2.
  6. Perform the Active Test operation with the engine idling (press the RIGHT or LEFT button to change the fuel injection volume).
  7. Monitor the output voltages of the air fuel ratio and heated oxygen sensors (AFS Voltage B1S1 and O2S B1S2) displayed on the tester.

HINT:
  1. The Control the Injection Volume for A/F Sensor operation lowers the fuel injection volume by 12.5% or increases the injection volume by 12.5%.
  2. Each sensor reacts in accordance with increases and decreases in the fuel injection volume.


Tester Display
(Sensor)
Injection Volume
Status
Voltage
AFS Voltage B1S1
(Air fuel ratio)
12.5%
Rich
Below 3.1 V
-12.5%
Lean
Higher than 3.4 V
O2S B1S2
(Heated oxygen)
12.5%
Rich
Higher than 0.55 V
-12.5%
Lean
Below 0.4 V

NOTICE:
The air fuel ratio sensor has an output delay of a few seconds and the heated oxygen sensor has a maximum output delay of approximately 20 seconds.


Case
Air Fuel Ratio Sensor (Sensor 1) Output Voltage
Heated Oxygen Sensor (Sensor 2) Output Voltage
Main Suspected Trouble Area
1
A150787E11
A151324E08
A150787E11
A150788E06
-
2
A150787E11
A150790E01
A150787E11
A150788E06
  1. Air fuel ratio sensor (sensor 1)
  2. Air fuel ratio sensor (sensor 1) heater
  3. Air fuel ratio sensor (sensor 1) circuit
3
A150787E11
A151324E08
A150787E11
A150790E01
  1. Heated oxygen sensor (sensor 2)
  2. Heated oxygen sensor (sensor 2) heater
  3. Heated oxygen sensor (sensor 2) circuit
4
A150787E11
A150790E01
A150787E11
A150790E01
  1. Fuel injector assembly
  2. Fuel pressure
  3. Gas leak from exhaust system (air fuel ratio extremely rich or lean)
  1. Following the Control the Injection Volume for A/F Sensor procedure enables technicians to check and graph the voltage outputs of both the air fuel ratio and heated oxygen sensors.
  2. To display the graph, enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Injection Volume for A/F Sensor / All Data / AFS Voltage B1S1 and O2S B1S2; then press the view button.

NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.

HINT:
  1. Sensor 1 refers to the sensor closest to the engine assembly.
  2. Sensor 2 refers to the sensor farthest away from the engine assembly.
  3. Read freeze frame data using the intelligent tester. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.

1.READ OUTPUT DTC (DTC P0136, P0137 OR P0138)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the tester on.

  1. Enter the following menus: Powertrain / Engine and ECT / DTC.

  1. Read the DTCs.

    Result 
    Result
    Proceed to
    DTC P0138 is output
    A
    DTC P0137 is output
    B
    DTC P0136 is output
    C
    DTC P0136, P0137 or P0138 and other DTCs are output
    D

    HINT:
    If any DTCs other than P0136, P0137 and P0138 are output, troubleshoot those DTCs first.



B
Go to step 9

C
Go to step 7

D
GO TO DTC CHART (Click here)
A


2.READ VALUE USING INTELLIGENT TESTER (OUTPUT VOLTAGE OF HEATED OXYGEN SENSOR)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the tester on.

  1. Start the engine.

  1. Enter the following menus: Powertrain / Engine and ECT / Data List / All Data / O2S B1S2.

  1. Allow the engine to idle.

  1. Read the heated oxygen sensor output voltage while idling.

    Result 
    Heated Oxygen Sensor Output Voltage
    Proceed to
    1.0 V or higher
    A
    Less than 1.0 V
    B



B
Go to step 5
A


3.INSPECT HEATED OXYGEN SENSOR (CHECK FOR SHORT)
A117841E99
  1. Disconnect the heated oxygen sensor connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    2 (+B) - 3 (OX1B)
    Always
    10 kΩ or higher
    2 (+B) - 4 (E2)
    Always
    10 kΩ or higher

    Text in Illustration 
    *a
    Component without harness connected
    (Heated Oxygen Sensor)



NG
REPLACE HEATED OXYGEN SENSOR (Click here)
OK


4.CHECK HARNESS AND CONNECTOR (CHECK FOR SHORT)
  1. Turn the ignition switch off and wait for 5 minutes or more.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:

    Tester Connection
    Condition
    Specified Condition
    E83-47 (HT1B) - E83-64 (OX1B)
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)  

5.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (CONTROL THE INJECTION VOLUME FOR A/F SENSOR)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the tester on.

  1. Start the engine.

  1. Warm up the engine.

  1. Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Injection Volume for A/F Sensor / All Data / AFS Voltage B1S1 and O2S B1S2.



  1. Change the fuel injection volume using the tester and monitor the voltage output of the air fuel ratio and heated oxygen sensors displayed on the tester.

    HINT:
    1. The Control the Injection Volume for A/F Sensor operation lowers the fuel injection volume by 12.5% or increases the injection volume by 12.5%.
    2. The air fuel ratio sensor is displayed as AFS Voltage B1S1, and the heated oxygen sensor is displayed as O2S B1S2 on the tester.
    3. The air fuel ratio sensor has an output delay of a few seconds and the heated oxygen sensor has a maximum output delay of approximately 20 seconds.
    4. If the sensor output voltage does not change (almost no reaction) while performing the Active Test, the sensor may be malfunctioning.


    Result 
    Tester Display
    (Sensor)
    Voltage Variation
    Proceed to
    AFS Voltage B1S1
    (Air fuel ratio)
    Alternates between higher and less than 3.3 V
    OK
    Remains higher than 3.3 V
    NG
    Remains less than 3.3 V
    NG

    HINT:
    A normal heated oxygen sensor voltage (O2S B1S2) reacts in accordance with increases and decreases in fuel injection volumes. When the air fuel ratio sensor (AFS Voltage B1S1) voltage remains either less or higher than 3.3 V despite the heated oxygen sensor indicating a normal reaction, the air fuel ratio sensor is malfunctioning.


    A121606E34



NG
Go to step 15
OK


6.INSPECT AIR FUEL RATIO SENSOR

HINT:
This air fuel ratio sensor test is to check the air fuel ratio sensor current during the fuel-cut operation. When the sensor is normal, the sensor current will indicate less than 3.6 mA in this test.

  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the tester on.

  1. Clear the DTCs (Click here).

  1. Start the engine and warm it up until the engine coolant temperature reaches 75°C (167°F) or higher.

  1. Drive the vehicle at 60 km/h (37 mph) or more for 10 minutes or more.

    CAUTION:
    When performing the confirmation driving pattern, obey all speed limits and traffic laws.

  1. Stop the vehicle.

  1. Enter the following menus: Powertrain / Engine and ECT / Data List / All Data / AFS Current B1S1.



  1. Drive the vehicle at 60 km/h (37 mph) or more and decelerate the vehicle for 5 seconds or more. Perform this 3 times.

    CAUTION:
    When performing the confirmation driving pattern, obey all speed limits and traffic laws.


    A152792E43

  1. Read the value of the air fuel ratio sensor current while the fuel-cut operation is being performed.

    Standard current:
    Less than 3.6 mA

    HINT:
    1. To measure the air fuel ratio sensor current precisely, perform the fuel-cut operation as long as possible.
    2. If it is difficult to measure the air fuel ratio sensor current, use the snapshot function of the tester.



OK
Go to step 12

NG
Go to step 15

7.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (CONTROL THE INJECTION VOLUME FOR A/F SENSOR)
  1. Connect the intelligent tester to the DLC3.

  1. Start the engine.

  1. Turn the tester on.

  1. Warm up the engine.

  1. Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Injection Volume for A/F Sensor / All Data / O2S B1S2.

  1. Change the fuel injection volume using the tester and monitor the voltage output of the heated oxygen sensors displayed on the tester.

    HINT:
    1. The Control the Injection Volume for A/F Sensor operation lowers the fuel injection volume by 12.5% or increases the injection volume by 12.5%.
    2. The heated oxygen sensor has a maximum output delay of approximately 20 seconds.

    Standard voltage:
    Fluctuates between 0.4 V or less and 0.55 V or higher.



NG
Go to step 9
OK


8.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (CONTROL THE INJECTION VOLUME FOR A/F SENSOR)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the tester on.

  1. Start the engine.

  1. Warm up the engine.

  1. Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Injection Volume for A/F Sensor / All Data / AFS Voltage B1S1 and O2S B1S2.



  1. Change the fuel injection volume using the tester and monitor the voltage output of the air fuel ratio and heated oxygen sensors displayed on the tester.

    HINT:
    1. The Control the Injection Volume for A/F Sensor operation lowers the fuel injection volume by 12.5% or increases the injection volume by 12.5%.
    2. The air fuel ratio sensor is displayed as AFS Voltage B1S1, and the heated oxygen sensor is displayed as O2S B1S2 on the tester.
    3. The air fuel ratio sensor has an output delay of a few seconds and the heated oxygen sensor has a maximum output delay of approximately 20 seconds.
    4. If the sensor output voltage does not change (almost no reaction) while performing the Active Test, the sensor may be malfunctioning.


    Result 
    Tester Display
    (Sensor)
    Voltage Variation
    Proceed to
    AFS Voltage B1S1
    (Air fuel ratio)
    Alternates between higher and less than 3.3 V
    OK
    Remains higher than 3.3 V
    NG
    Remains less than 3.3 V
    NG

    HINT:
    A normal heated oxygen sensor voltage (O2S B1S2) reacts in accordance with increases and decreases in fuel injection volumes. When the air fuel ratio sensor (AFS Voltage B1S1) voltage remains either less or higher than 3.3 V despite the heated oxygen sensor indicating a normal reaction, the air fuel ratio sensor is malfunctioning.


    A121606E34



NG
Go to step 15
OK

CHECK ENGINE TO DETERMINE CAUSE OF EXTREMELY RICH OR LEAN ACTUAL AIR FUEL RATIO (FUEL INJECTOR ASSEMBLY, FUEL SYSTEM, INTAKE SYSTEM, ETC.) (Click here)  

9.CHECK FOR EXHAUST GAS LEAK
  1. Check for exhaust gas leaks.

    OK:
    No gas leaks.



NG
REPAIR OR REPLACE EXHAUST GAS LEAK POINT
OK


10.INSPECT HEATED OXYGEN SENSOR (HEATER RESISTANCE)
  1. Inspect the heated oxygen sensor (Click here).



NG
REPLACE HEATED OXYGEN SENSOR (Click here)
OK


11.CHECK HARNESS AND CONNECTOR (HEATED OXYGEN SENSOR - ECM)
  1. Disconnect the heated oxygen sensor connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:

    Tester Connection
    Condition
    Specified Condition
    E21-1 (HT1B) - E83-47 (HT1B)
    Always
    Below 1 Ω
    E21-3 (OX1B) - E83-64 (OX1B)
    Always
    Below 1 Ω
    E21-4 (E2) - E83-87 (EX1B)
    Always
    Below 1 Ω
    E21-1 (HT1B) or E83-47 (HT1B) - Body ground
    Always
    10 kΩ or higher
    E21-3 (OX1B) or E83-64 (OX1B) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


12.REPLACE HEATED OXYGEN SENSOR
  1. Replace the heated oxygen sensor (Click here).


NEXT


13.PERFORM CONFIRMATION DRIVING PATTERN
  1. Perform Confirmation Driving Pattern.


NEXT


14.CHECK WHETHER DTC OUTPUT RECURS (DTC P0136, P0137 OR P0138)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the tester on.

  1. Enter the following menus: Powertrain / Engine and ECT / Utility / All Readiness.

  1. Input the DTC: P0136, P0137 or P0138.

  1. Check that the DTC monitor is NORMAL. If the DTC monitor is INCOMPLETE, perform the driving pattern again but increase the vehicle speed.

    Result 
    Result
    Proceed to
    ABNORMAL
    (DTC P0136, P0137 or P0138 is output)
    A
    NORMAL
    (DTC is not output)
    B



B
END
A

REPLACE AIR FUEL RATIO SENSOR (Click here)  

15.REPLACE AIR FUEL RATIO SENSOR
  1. Replace the air fuel ratio sensor (Click here).


NEXT


16.PERFORM CONFIRMATION DRIVING PATTERN
  1. Perform Confirmation Driving Pattern.


NEXT


17.CHECK WHETHER DTC OUTPUT RECURS (DTC P0136 OR P0138)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the tester on.

  1. Enter the following menus: Powertrain / Engine and ECT / Utility / All Readiness.

  1. Input the DTC: P0136 or P0138.

  1. Check that the DTC monitor is NORMAL. If the DTC monitor is INCOMPLETE, perform the driving pattern again but increase the vehicle speed.

    Result 
    Result
    Proceed to
    ABNORMAL
    (DTC P0136 or P0138 is output)
    A
    NORMAL
    (DTC is not output)
    B



B
END
A

REPLACE HEATED OXYGEN SENSOR (Click here)