Home › Vehicle Interior › HEATING / AIR CONDITIONING › CONDENSER

CONDENSER > INSTALLATION

for Preparation Click here



1. INSTALL COOLER CONDENSER ASSEMBLY


    E227497
  1. Engage the 2 guides as shown in the illustration.

  1. Install the cooler condenser assembly with the 4 bolts.

    Torque:
    5.0 N*m{ 51 kgf*cm , 44 in.*lbf }

    HINT:
    If the condenser is replaced with a new one, add compressor oil to the new condenser.

    Capacity:
    40 cc (1.4 fl. oz.)

    Compressor oil:
    ND-OIL 8 or equivalent



2. CONNECT AIR CONDITIONER TUBE AND ACCESSORY ASSEMBLY
  1. Remove the vinyl tape from the tube and the connector part of the cooler condenser assembly.

  1. Sufficiently apply compressor oil to a new O-ring and the fitting surface of the tube joint.

    Compressor oil:
    ND-OIL 8 or equivalent

  1. Install the O-ring to the air conditioner tube and accessory assembly.

  1. Install the air conditioner tube and accessory assembly to the cooler condenser assembly with the bolt.

    Torque:
    9.8 N*m{ 100 kgf*cm , 87 in.*lbf }



3. CONNECT NO. 1 COOLER REFRIGERANT DISCHARGE HOSE
  1. Remove the attached vinyl tape from the pipe and the connecting part of the cooler condenser assembly.

  1. Sufficiently apply compressor oil to a new O-ring and the fitting surface of the pipe joint.

    Compressor oil:
    ND-OIL 8 or equivalent

  1. Install the O-ring to the No. 1 cooler refrigerant discharge hose.

  1. Install the No. 1 cooler refrigerant discharge hose to the cooler condenser assembly with the bolt.

    Torque:
    9.8 N*m{ 100 kgf*cm , 87 in.*lbf }



4. INSTALL RADIATOR SIDE DEFLECTOR LH
  1. Engage the guide and 3 claws to install the radiator side deflector LH.



5. INSTALL RADIATOR SIDE DEFLECTOR RH
  1. Engage the guide and 3 claws to install the radiator side deflector RH.



6. INSTALL UPPER RADIATOR SUPPORT (for 1AZ-FE)
  1. Install the 2 radiator support cushions to the radiator assembly.

  1. Install the upper radiator support with the 5 bolts and connect the hood lock control cable clamp to the upper radiator support.

    Torque:
    12 N*m{ 122 kgf*cm , 9 ft.*lbf }

  1. Connect the 2 connectors.



7. INSTALL UPPER RADIATOR SUPPORT (for 2AR-FE)
  1. Install the 2 radiator support cushions to the radiator assembly.

  1. Install the upper radiator support with the 5 bolts and connect the hood lock control cable clamp to the upper radiator support.

    Torque:
    12 N*m{ 122 kgf*cm , 9 ft.*lbf }

  1. Connect the 2 connectors.



8. INSTALL UPPER RADIATOR SUPPORT (for 2GR-FE)
  1. Install the 2 radiator support cushions to the radiator assembly.

  1. Install the upper radiator support with the 5 bolts and connect the hood lock control cable clamp to the upper radiator support.

    Torque:
    12 N*m{ 122 kgf*cm , 9 ft.*lbf }

  1. Connect the 2 connectors.



9. INSTALL HOOD LOCK ASSEMBLY (for LHD)


    B281674
  1. Apply MP grease to the sliding areas of the lock.

  1. Connect the hood lock control cable assembly.

  1. Install the hood lock assembly with the 2 bolts and hood lock bolt.

    Torque:
    7.5 N*m{ 76 kgf*cm , 66 in.*lbf }

    HINT:
    The hood lock nut cap is a non-reusable part. Be sure to install it after performing the Inspect Hood Sub-assembly and Adjust Hood Sub-assembly steps.

  1. Connect the connector.



10. INSTALL HOOD LOCK ASSEMBLY (for RHD)


    B281675
  1. Apply MP grease to the sliding areas of the lock.

  1. Connect the hood lock control cable assembly.

  1. Install the hood lock assembly with the 2 bolts and hood lock bolt.

    Torque:
    7.5 N*m{ 76 kgf*cm , 66 in.*lbf }

    HINT:
    The hood lock nut cap is a non-reusable part. Be sure to install it after performing the Inspect Hood Sub-assembly and Adjust Hood Sub-assembly steps.

  1. Connect the connector.



11. INSTALL RADIATOR RESERVE TANK ASSEMBLY (for 1AZ-FE)
  1. Install the radiator reserve tank assembly with the 2 bolts.

    Torque:
    7.0 N*m{ 71 kgf*cm , 62 in.*lbf }

  1. Connect the radiator reserve tank hose.



12. INSTALL RADIATOR RESERVE TANK ASSEMBLY (for 2AR-FE)
  1. Install the radiator reserve tank with the 2 bolts.

    Torque:
    7.0 N*m{ 71 kgf*cm , 62 in.*lbf }

  1. Connect the radiator reserve tank hose.



13. INSTALL RADIATOR RESERVE TANK ASSEMBLY (for 2GR-FE)
  1. Install the radiator reserve tank with the 2 bolts.

    Torque:
    7.0 N*m{ 71 kgf*cm , 62 in.*lbf }

  1. Connect the radiator reserve tank hose.



14. INSTALL INLET AIR CLEANER ASSEMBLY (for 1AZ-FE)
  1. Install the inlet air cleaner assembly with the 2 bolts.

    Torque:
    8.0 N*m{ 82 kgf*cm , 71 in.*lbf }



15. INSTALL INLET AIR CLEANER ASSEMBLY (for 2AR-FE)
  1. Install the inlet air cleaner with the 2 bolts.

    Torque:
    8.0 N*m{ 82 kgf*cm , 71 in.*lbf }



16. INSTALL INLET NO. 1 AIR CLEANER (for 2GR-FE)


    A256227
  1. Install the inlet No. 1 air cleaner to the intake air resonator sub-assembly.

  1. Engage the pin to the radiator support.



17. INSTALL INLET NO. 2 AIR CLEANER (for 2GR-FE)
  1. Install the inlet No. 2 air cleaner to the air cleaner case sub-assembly with the 2 bolts.

    Torque:
    8.0 N*m{ 82 kgf*cm , 71 in.*lbf }

  1. Connect the 2 wire harness clamps and vacuum hose clamp.



18. INSTALL FRONT BUMPER ASSEMBLY
(Click here)


19. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).



20. CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT
  1. Perform vacuum purging using a vacuum pump or appropriate equipment.



  1. Charge the air conditioning system with refrigerant.

    Refrigerant type:
    HFC-134a (R134a)



    E143108E11


    Text in Illustration 
    *a
    Sub-cool System
    *b
    High Pressure
    *c
    Refrigerant Amount
    *d
    Standard charge amount
    *e
    Charge additional 100 g (3.5 oz.)
    *f
    Point where bubbles disappear
    *g
    Mean value in proper range
    *h
    Overcharged

    Standard charge amount:
    450 to 550g (15.9 to 19.4oz.)

    SST
    09985-20010   (09985-02010, 09985-02050, 09985-02060, 09985-02070, 09985-02080, 09985-02090, 09985-02110, 09985-02130, 09985-02140, 09985-02150)

    NOTICE:
    1. Do not turn the A/C switch on before charging the air conditioning system with refrigerant. Doing so may cause the compressor to work without refrigerant, resulting in overheating of the compressor.
    2. The refrigerant amount should be checked by quantity (weight).

    HINT:
    Ensure that sufficient refrigerant is available to recharge the system when using a refrigerant recovery unit. Refrigerant recovery units are not always able to recover 100% of the refrigerant from an air conditioning system.



21. WARM UP ENGINE
  1. Keep the A/C switch on for at least 2 minutes to warm up the compressor.

    NOTICE:
    To prevent damage to the compressor, be sure to warm up the compressor when turning the air conditioning on after removing and installing air conditioning system lines (including the compressor).



22. INSPECT FOR REFRIGERANT LEAK
  1. After recharging the air conditioning system with refrigerant, inspect for refrigerant leaks using a halogen leak detector.

  1. Carry out the test under the following conditions:

    1. Ignition switch off.
    2. Secure good ventilation (the halogen leak detector may react to volatile gases which are not refrigerant, such as gasoline vapor and exhaust gas).
    3. Repeat the inspection 2 or 3 times.
    4. Measure the pressure to make sure that there is some refrigerant remaining in the air conditioning system.
      Pressure when the compressor is off: approx. 392 to 588 kPa (3.9 to 5.9 kgf/cm2, 57 to 85 psi)



    I042222E40
  1. Using a halogen leak detector, inspect for refrigerant leaks from the air conditioning system.
    Text in Illustration 
    *1
    Halogen Leak Detector
    *a
    Inspect for Leak



    N014519E08
  1. Bring the halogen leak detector close to the drain hose with the detector power off, and then turn the detector on.
    Text in Illustration 
    *1
    Halogen Leak Detector
    *2
    Drain Hose

    HINT:
    1. After the blower motor has stopped, leave the cooling unit for more than 15 minutes.
    2. Bring the halogen leak detector sensor under the drain hose.
    3. When bringing the halogen leak detector close to the drain hose, make sure that the halogen leak detector does not react to volatile gases. If it is not possible to avoid interference from volatile gases, the vehicle should be lifted up to allow checking for leaks.

  1. If a refrigerant leak is not detected from the drain hose, remove the blower motor control from the cooling unit. Insert the halogen leak detector sensor into the unit and check for a leak.

  1. Disconnect the pressure sensor connector and leave it for approximately 20 minutes. Bring the halogen leak detector close to the pressure sensor and check for a leak.

    HINT:
    When checking for leaks, the presence of oily dirt at a joint can indicate a leak.



23. ADJUST HOOD SUB-ASSEMBLY
(Click here)