DTC P0741 Torque Converter Clutch Solenoid Performance (Shift Solenoid Valve DSL) |
| DTC No. | DTC Detection Condition | Trouble Area |
| P0741 | Lock-up does not occur when driving in lock-up range Lock-up remains ON in lock-up OFF range (2-trip detection logic) |
|
| PERFORM ACTIVE TEST |
Warm up the engine.
Turn the ignition switch off.
Connect the Intelligent tester to the DLC3.
Turn the ignition switch to ON.
Select the item "Enter / Powertrain / Engine and ECT / Active Test".
According to the display on the tester, perform the "Active Test".
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Activate the Lock Up | [Test Details] Control the shift solenoid DSL to set the automatic transaxle to the lock-up condition. [Vehicle Condition]
| ON/OFF | Possible to check the DSL operation. |
Lightly depress the accelerator pedal and check that the engine speed does not change abruptly.

| 1.CHECK OTHER DTCS OUTPUT (IN ADDITION TO DTC P0741) |
Connect the Intelligent tester to the DLC3.
Turn the ignition switch to ON and turn the Intelligent tester main switch on.
Select the item "Enter / Powertrain / Engine and ECT / Trouble Codes".
Read the DTCs using the Intelligent tester.
| Display (DTC output) | Proceed to |
| Only "P0741" is output | A |
| "P0741" and other DTCs | B |
|
| ||||
| A | |
| 2.INSPECT TRANSMISSION WIRE (DSL) |
![]() |
Disconnect the transmission wire connector from the transaxle.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 3 (DSL) - Body ground | 20°C (68°F) | 11 to 13 Ω |
| *a | Component without harness connected (Transmission Wire) |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
![]() |
Connect the transmission wire connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| E83-79 (DSL) - Body ground | 20°C (68°F) | 11 to 13 Ω |
| *a | Front view of wire harness connector (to ECM) |
|
| ||||
| OK | |
| 4.INSPECT SHIFT SOLENOID VALVE (DSL) |
![]() |
Remove the shift solenoid valve DSL.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Solenoid Connector (DSL) - Solenoid Body (DSL) | 20°C (68°F) | 11 to 13 Ω |
Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.
| *1 | Shift Solenoid Valve DSL |
|
| ||||
| OK | |
| 5.CHECK TRANSMISSION WIRE |
|
| ||||
| OK | |
| 6.INSPECT TRANSMISSION VALVE BODY ASSEMBLY |
Check the transmission valve body assembly (Click here).
|
| ||||
| OK | |
| 7.INSPECT TORQUE CONVERTER ASSEMBLY |
Check the torque converter assembly (Click here).
|
| ||||
| OK | ||
| ||