ENGINE IMMOBILISER SYSTEM (w/ Smart Key System) > Security Indicator Light Does not Blink |

| 1.PERFORM ACTIVE TEST USING TECHSTREAM (SECURITY INDICATOR LIGHT) |
Connect the Techstream to the DLC3.
Turn the engine switch on (IG).
Turn the Techstream on.
Enter the following menus: Body Electrical / Smart Key / Active Test.
Perform the Active Test according to the display on the Techstream.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Immobiliser Indicator | Security indicator light | OFF/ON | - |
| Result | Proceed to |
| OK (w/ Theft Deterrent System) | A |
| OK (w/o Theft Deterrent System) | B |
| NG | C |
|
| ||||
|
| ||||
| A | |
| 2.CHECK SECURITY INDICATOR LIGHT OPERATION |
When the immobiliser is set, check that the security indicator light blinks.*1
When the theft deterrent system is in the arming preparation state, check that the security indicator light on (Click here).*2
| Result | Proceed to |
| *1 is NG (*2 is OK) | A |
| *2 is NG (*1 is OK) | B |
|
| ||||
| A | ||
| ||
| 3.CHECK HARNESS AND CONNECTOR (SECURITY INDICATOR LIGHT (AIR CONDITIONING CONTROL ASSEMBLY) - CERTIFICATION ECU (SMART KEY ECU ASSEMBLY)) |
Disconnect the I56 security indicator light (air conditioning control assembly) connector.
Disconnect the I78 certification ECU (smart key ECU assembly) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| I78-18 (IND)- I56-1 (LP) | Always | Below 1 Ω |
| I78-18 (IND) - Body ground | Always | 10 kΩ or higher |
| I56-6 (GND) - Body ground | Always | Below 1 Ω |
|
| ||||
| OK | |
| 4.CHECK CERTIFICATION ECU (SMART KEY ECU ASSEMBLY) |
Reconnect the G28 certification ECU (smart key ECU assembly) connector.
Measure the voltage and check the pulse according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| I56-1 (LP) - I56-6 (GND) | Engine switch off → engine switch on (IG) | Pulse generation → Below 2 V |
|
| ||||
| OK | ||
| ||