DTC U0233 Lost Communication with Blind Spot Monitor Master Module |
| DTC No. | DTC Detection Condition | Trouble Area |
| U0233 | No communication from the blind spot monitor sensor RH continues. |
|

| 1.RECONFIRM DTC OUTPUT |
Reconfirm DTCs.
| Result | Proceed to |
| U1002 is not output from network gateway ECU (Techstream display/Gateway) | A |
| U1002 is output from network gateway ECU (Techstream display/Gateway) | B |
|
| ||||
| A | |
| 2.CHECK FOR OPEN IN CAN BUS LINES (BLIND SPOT MONITOR SENSOR RH BRANCH LINE) |
Disconnect the cable from the negative (-) battery terminal.
![]() |
Disconnect the blind spot monitor sensor RH connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| O28-8 (CA1P) - O28-4 (CA1N) | Cable disconnected from negative (-) battery terminal | 54 to 69 Ω |
| *a | Front view of wire harness connector (to Blind Spot Monitor Sensor RH) |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| O28-1 (BRGD) - Body ground | Always | Below 1 Ω |
| *a | Front view of wire harness connector (to Blind Spot Monitor Sensor RH) |
Connect the cable to the negative (-) battery terminal.
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| O28-5 (BRB) - Body ground | Ignition switch ON | 11 to 14 V |
| *a | Front view of wire harness connector (to Blind Spot Monitor Sensor RH) |
|
| ||||
| OK | ||
| ||