BLIND SPOT MONITOR SYSTEM > Main Switch Circuit |

| 1.READ VALUE USING TECHSTREAM |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Body Electrical / Blind spot monitor Master / Data list.
According to the display on Techstream, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| BSM Main SW | Blind spot monitor main switch (warning canceling switch assembly) / ON or OFF | ON: Blind spot monitor main switch (warning canceling switch assembly) on OFF: Blind spot monitor main switch (warning canceling switch assembly) off | - |
| Result | Proceed to |
| The display does not change as shown above when the blind spot monitor main switch (warning canceling switch assembly) is operated. | A |
| The display changes as shown above when the blind spot monitor main switch (warning canceling switch assembly) is operated. | B |
|
| ||||
| A | |
| 2.INSPECT BLIND SPOT MONITOR MAIN SWITCH (WARNING CANCELING SWITCH ASSEMBLY) |
Remove the blind spot monitor main switch (warning canceling switch assembly) (Click here).
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| I10-11 (B) - I10-8 (D) | Blind spot monitor main switch assembly is on (not protruding) | Below 1 Ω |
| I10-11 (B) - I10-8 (D) | Blind spot monitor main switch assembly is off (protruding) | 10 kΩ or higher |
| *a | Component without harness connected (Blind Spot Monitor Main Switch (Warning Canceling Switch Assembly)) |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR MAIN SWITCH - BATTERY) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| I10-11 (B) - Body ground | Ignition switch ON | 11 to 14 V |
| I10-11 (B) - Body ground | Ignition switch off | Below 1 V |
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR MAIN SWITCH - BLIND SPOT MONITOR SENSOR RH) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| O28-3 (BSSW) - I10-8 (D) | Always | Below 1 Ω |
| O28-3 (BSSW) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||