Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM
RM2030EQ _58 Vehicle Interior _014672 HEATING / AIR CONDITIONING _0074651 AIR CONDITIONING SYSTEM C

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  B1479/79  Flow Sensor Circuit  


DESCRIPTION

The A/C flow sensor, which is mounted on the compressor, is used to detect the amount of refrigerant flow. The A/C flow sensor converts the amount of refrigerant flow that is detected to a voltage value to send it to the air conditioning amplifier assembly. The voltage value sent from the A/C flow sensor changes depending on the amount of refrigerant flow. As the amount of refrigerant flow becomes larger, the voltage becomes lower. As the amount of refrigerant flow becomes smaller, the voltage becomes higher. The air conditioning amplifier assembly supplies 5 V to the A/C flow sensor and monitors changes in the voltage value sent from the A/C flow sensor. The air conditioning amplifier assembly then sends a signal to the ECM via CAN communication to allow the ECM to control the engine speed while the air conditioning is on.

DTC No. Detection Item DTC Detection Condition Trouble Area Memory
B1479/79 Flow Sensor Circuit Open or short in A/C flow sensor circuit
·

Cooler compressor assembly (A/C flow sensor)

·

Harness or connector between cooler compressor assembly (A/C flow sensor) and air conditioning amplifier assembly

·

Air conditioning amplifier assembly


Memorized
(4 sec. or more)*1

*1: The air conditioning amplifier assembly stores the DTC of the respective malfunction if it has occurred for the period of time indicated in the brackets.


WIRING DIAGRAM

E227647E19
0.76,2.698 1.104,2.854 0.344,0.156 10 false E75 1.24,0.635 1.677,0.823 0.438,0.188 10 false QUFL 1.24,1.385 1.667,1.573 0.427,0.188 10 false SGFL 1.271,2.135 1.625,2.323 0.354,0.188 10 false S5FL 1.75,1.99 1.896,2.177 0.146,0.188 10 false 1 1.74,1.26 1.885,1.448 0.146,0.188 10 false 2 1.74,0.5 1.885,0.688 0.146,0.188 10 false 3 5.563,0.646 5.99,0.823 0.427,0.177 10 false FLOQ 5.552,1.396 5.917,1.573 0.365,0.177 10 false SG-2 5.542,2.135 5.906,2.313 0.365,0.177 10 false S5-1 5.313,2.021 5.5,2.198 0.188,0.177 10 false 30 5.302,1.26 5.49,1.438 0.188,0.177 10 false 13 5.385,0.521 5.51,0.698 0.125,0.177 10 false 7 5.302,2.656 5.729,3.042 0.427,0.385 10 false I77 5.302,2.823 6.896,3.219 1.594,0.396 10 false Air Conditioning Amplifier Assembly 0.76,2.865 2.042,3.438 1.281,0.573 10 false Cooler Compressor Assembly (A/C Flow Sensor)

PROCEDURE

1.READ VALUE USING INTELLIGENT TESTER
a.

Connect the intelligent tester to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the intelligent tester on.


d.

Enter the following menus: Body / Air Conditioner / Data List.


e.

Check the value(s) by referring to the table below.

Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Flow Sensor A/C flow sensor Min.: 0.0 V
Max.: 5.0 V
A/C on, Blower switch HI: 0.7 to 3.8 V
A/C off, Blower switch off: 3.8 to 4.2 V
A/C flow sensor is malfunctioning when a constant value between 0.7 and 4.2 V is displayed continuously for more than 4 seconds.
Body Electrical > Air Conditioner > Data List
Tester Display
Flow Sensor
50003 121 160
OK:

The display is as specified in the Normal Condition column.



Result:
Result Proceed to
OK (When troubleshooting according to Problem Symptoms Table) A
OK (When troubleshooting according to the DTC) B
NG (When a constant value between 0.7 and 4.2 V is displayed continuously for more than 4 seconds) C



A

2.READ VALUE USING INTELLIGENT TESTER

B

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

C

3.REPLACE COOLER COMPRESSOR ASSEMBLY (A/C FLOW SENSOR)
2.READ VALUE USING INTELLIGENT TESTER
a.

Connect the intelligent tester to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the intelligent tester on.


d.

Enter the following menus: Body / Air Conditioner / Data List.


e.

Check the value(s) by referring to the table below.

Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
A/C Cutoff Signal A/C control cutoff signal OFF or ON The ECM sends the air conditioning control cutoff signal displayed -
Body Electrical > Air Conditioner > Data List
Tester Display
A/C Cutoff Signal
50003 121 166

Result:
Result Proceed to
Value in Data List indicates OFF A
Value in Data List indicates ON B



A

3.REPLACE COOLER COMPRESSOR ASSEMBLY (A/C FLOW SENSOR)

B

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE

3.REPLACE COOLER COMPRESSOR ASSEMBLY (A/C FLOW SENSOR)
a.

Replace the cooler compressor assembly (A/C flow sensor).

Click hereVehicle Interior>HEATING / AIR CONDITIONING>COMPRESSOR>REMOVAL

HINT:

Since the cooler compressor assembly (A/C flow sensor) cannot be inspected while it is removed from the vehicle, replace the cooler compressor assembly (A/C flow sensor) with a new or a known good one and check that the condition returns to normal.



b.

Check for the DTC.

Body Electrical > Air Conditioner > Trouble Codes
50001 121
Result:
Result Proceed to
DTC B1479/79 is not output A
DTC B1479/79 is output B




A

END

B

4.CHECK HARNESS AND CONNECTOR (COOLER COMPRESSOR ASSEMBLY (A/C FLOW SENSOR) - AIR CONDITIONING AMPLIFIER ASSEMBLY)
4.CHECK HARNESS AND CONNECTOR (COOLER COMPRESSOR ASSEMBLY (A/C FLOW SENSOR) - AIR CONDITIONING AMPLIFIER ASSEMBLY)
a.

Disconnect the I77 air conditioning amplifier assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
I77-7 (FLOQ) - E75-3 (QUFL) Always Below 1 Ω
I77-13 (SG-2) - E75-2 (SGFL) Always Below 1 Ω
I77-30 (S5-1) - E75-1 (S5FL) Always Below 1 Ω
I77-7 (FLOQ) - Body ground Always 10 kΩ or higher
I77-13 (SG-2) - Body ground Always 10 kΩ or higher
I77-30 (S5-1) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR