Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › 2012.02–2016.05
RM2040EQ _51 Engine / Hybrid System _014692 HYBRID / BATTERY CONTROL _0074885 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P0A92-521  Hybrid Generator Performance  


DESCRIPTION

For a description of MG1 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A90-251).

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0A92-521 Hybrid Generator Performance Generator system malfunction
·

Hybrid vehicle transaxle assembly

·

Inverter with converter assembly

·

Wire harness or connector

·

Power management control ECU


Comes on Master Warning Light:
Comes on

CAUTION / NOTICE / HINT

CAUTION:
·

Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·

After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


PROCEDURE

1.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the intelligent tester to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / DTC.

Powertrain > Hybrid Control > Trouble Codes
50001 236

d.

Check if DTCs are output.

Result:
Result Proceed to
Only P0A92-521 is output or P0A92-521 and DTCs other than the ones in the table below are also output. A
Any of the following DTCs are also output. B


DTC No. Relevant Diagnosis
P0A1A (all INF codes)*1 Generator Control Module
P0A1B (all INF codes)*1 Drive Motor "A" Control Module
P0A1D (all INF codes)*1 Hybrid Powertrain Control Module
P0A3F-243 Drive Motor "A" Position Sensor Circuit
P0A40-500 Drive Motor "A" Position Sensor Circuit Range / Performance
P0A41-245 Drive Motor "A" Position Sensor Circuit Low
P0A4B-253 Generator Position Sensor Circuit
P0A4C-513 Generator Position Sensor Circuit Range / Performance
P0A4D-255 Generator Position Sensor Circuit Low
P0A60 (all INF codes)*1 Drive Motor "A" Phase V Current
P0A63 (all INF codes)*1 Drive Motor "A" Phase W Current
P0A72 (all INF codes)*1 Generator Phase V Current
P0A75 (all INF codes)*1 Generator Phase W Current
P0A78-266, 267, 279, 287, 503, 504, 505, 506, 586, 806, 807, 808 Drive Motor "A" Inverter Performance
P0A7A-203, 325, 517, 518, 809, 810, 811 Generator Inverter Performance
P0A94-547, 548, 549, 554, 555, 556, 585, 587, 589, 590 DC / DC Converter Performance
P0AA6 (all INF codes)*1 Hybrid Battery Voltage System Isolation Fault
P0C76-523 Hybrid Battery System Discharge Time Too Long
P3004-132 High Voltage Power Resource

HINT:
·

*1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.

·

P0A92-521 may be output due to a malfunction which causes the DTCs in the table above to be output. In this case, first troubleshoot the output DTCs in the table above. Then, perform a reproduction test to check that no DTCs are output.




e.

Turn the power switch off.



A

2.CHECK DTC OUTPUT (HYBRID CONTROL)

B

2.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the intelligent tester to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / DTC.

Powertrain > Hybrid Control > Trouble Codes
50001 236

d.

Check if DTCs are output.

Result:
Result Proceed to
Any of the following DTCs are also output. A
Only P0A92-521 is output or P0A92-521 and DTCs other than the ones in the table below are also output. B


DTC No. Relevant Diagnosis
P0A78-306 Drive Motor "A" Inverter Performance
P0A90-251, 509 Drive Motor "A" Performance

HINT:

When the DTCs listed in the table above are also output, there may be a short between the HSDN (MG shut down signal) circuit and power circuit.



e.

Turn the power switch off.



A

3.CHECK POWER MANAGEMENT CONTROL ECU

B

4.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
3.CHECK POWER MANAGEMENT CONTROL ECU

OK

4.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

NG

7.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY)
4.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

OK

5.CHECK INVERTER WITH CONVERTER ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION)

NG

CONNECT SECURELY

5.CHECK INVERTER WITH CONVERTER ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION)

A

6.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG1)

B

REPLACE MALFUNCTIONING PARTS

C

CONNECT SECURELY

6.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG1)

OK

REPLACE INVERTER WITH CONVERTER ASSEMBLY

NG

REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY

7.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY)

OK

8.CHECK INVERTER WITH CONVERTER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

8.CHECK INVERTER WITH CONVERTER ASSEMBLY

OK

NG

REPLACE INVERTER WITH CONVERTER ASSEMBLY