Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID BATTERY SYSTEM
RM2040EQ _51 Engine / Hybrid System _014692 HYBRID / BATTERY CONTROL _0074886 HYBRID BATTERY SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID BATTERY SYSTEM  P0B3D-123  Hybrid Battery Voltage Sensor "A" Circuit Low  P0B42-123  Hybrid Battery Voltage Sensor "B" Circuit Low  P0B47-123  Hybrid Battery Voltage Sensor "C" Circuit Low  P0B4C-123  Hybrid Battery Voltage Sensor "D" Circuit Low  P0B51-123  Hybrid Battery Voltage Sensor "E" Circuit Low  P0B56-123  Hybrid Battery Voltage Sensor "F" Circuit Low  P0B5B-123  Hybrid Battery Voltage Sensor "G" Circuit Low  P0B60-123  Hybrid Battery Voltage Sensor "H" Circuit Low  P0B65-123  Hybrid Battery Voltage Sensor "I" Circuit Low  P0B6A-123  Hybrid Battery Voltage Sensor "J" Circuit Low  P0B6F-123  Hybrid Battery Voltage Sensor "K" Circuit Low  P0B74-123  Hybrid Battery Voltage Sensor "L" Circuit Low  P0B79-123  Hybrid Battery Voltage Sensor "M" Circuit Low  P0B7E-123  Hybrid Battery Voltage Sensor "N" Circuit Low  P0B83-123  Hybrid Battery Voltage Sensor "O" Circuit Low  P0B88-123  Hybrid Battery Voltage Sensor "P" Circuit Low  P0B8D-123  Hybrid Battery Voltage Sensor "Q" Circuit Low  P0B92-123  Hybrid Battery Voltage Sensor "R" Circuit Low  P308A-123  Hybrid Battery Voltage Sensor All Circuits Low  


DESCRIPTION

Refer to the description for DTC P0A80-123.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>P0A80-123

HINT:
·

Values smaller than 2.0 V may not be shown in the Data List because a fail-safe value is substituted.

·

Hybrid battery voltage sensor in the DTC titles refers to the battery smart unit.



DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0B3D-123 Hybrid Battery Voltage Sensor "A" Circuit Low Each battery block voltage becomes less than 2.5 V (open) (1 trip detection)
·

Battery smart unit

·

HV battery


Comes on Master Warning Light:
Comes on
P0B42-123 Hybrid Battery Voltage Sensor "B" Circuit Low Each battery block voltage becomes less than 2.5 V (open) (1 trip detection)
·

Battery smart unit

·

HV battery


Comes on Master Warning Light:
Comes on
P0B47-123 Hybrid Battery Voltage Sensor "C" Circuit Low Each battery block voltage becomes less than 2.5 V (open) (1 trip detection)
·

Battery smart unit

·

HV battery


Comes on Master Warning Light:
Comes on
P0B4C-123 Hybrid Battery Voltage Sensor "D" Circuit Low Each battery block voltage becomes less than 2.5 V (open) (1 trip detection)
·

Battery smart unit

·

HV battery


Comes on Master Warning Light:
Comes on
P0B51-123 Hybrid Battery Voltage Sensor "E" Circuit Low Each battery block voltage becomes less than 2.5 V (open) (1 trip detection)
·

Battery smart unit

·

HV battery


Comes on Master Warning Light:
Comes on
P0B56-123 Hybrid Battery Voltage Sensor "F" Circuit Low Each battery block voltage becomes less than 2.5 V (open) (1 trip detection)
·

Battery smart unit

·

HV battery


Comes on Master Warning Light:
Comes on
P0B5B-123 Hybrid Battery Voltage Sensor "G" Circuit Low Each battery block voltage becomes less than 2.5 V (open) (1 trip detection)
·

Battery smart unit

·

HV battery


Comes on Master Warning Light:
Comes on
P0B60-123 Hybrid Battery Voltage Sensor "H" Circuit Low Each battery block voltage becomes less than 2.5 V (open) (1 trip detection)
·

Battery smart unit

·

HV battery


Comes on Master Warning Light:
Comes on
P0B65-123 Hybrid Battery Voltage Sensor "I" Circuit Low Each battery block voltage becomes less than 2.5 V (open) (1 trip detection)
·

Battery smart unit

·

HV battery


Comes on Master Warning Light:
Comes on
P0B6A-123 Hybrid Battery Voltage Sensor "J" Circuit Low Each battery block voltage becomes less than 2.5 V (open) (1 trip detection)
·

Battery smart unit

·

HV battery


Comes on Master Warning Light:
Comes on
P0B6F-123 Hybrid Battery Voltage Sensor "K" Circuit Low Each battery block voltage becomes less than 2.5 V (open) (1 trip detection)
·

Battery smart unit

·

HV battery


Comes on Master Warning Light:
Comes on
P0B74-123 Hybrid Battery Voltage Sensor "L" Circuit Low Each battery block voltage becomes less than 2.5 V (open) (1 trip detection)
·

Battery smart unit

·

HV battery


Comes on Master Warning Light:
Comes on
P0B79-123 Hybrid Battery Voltage Sensor "M" Circuit Low Each battery block voltage becomes less than 2.5 V (open) (1 trip detection)
·

Battery smart unit

·

HV battery


Comes on Master Warning Light:
Comes on
P0B7E-123 Hybrid Battery Voltage Sensor "N" Circuit Low Each battery block voltage becomes less than 2.5 V (open) (1 trip detection)
·

Battery smart unit

·

HV battery


Comes on Master Warning Light:
Comes on
P0B83-123 Hybrid Battery Voltage Sensor "O" Circuit Low Each battery block voltage becomes less than 2.5 V (open) (1 trip detection)
·

Battery smart unit

·

HV battery


Comes on Master Warning Light:
Comes on
P0B88-123 Hybrid Battery Voltage Sensor "P" Circuit Low Each battery block voltage becomes less than 2.5 V (open) (1 trip detection)
·

Battery smart unit

·

HV battery


Comes on Master Warning Light:
Comes on
P0B8D-123 Hybrid Battery Voltage Sensor "Q" Circuit Low Each battery block voltage becomes less than 2.5 V (open) (1 trip detection)
·

Battery smart unit

·

HV battery


Comes on Master Warning Light:
Comes on
P0B92-123 Hybrid Battery Voltage Sensor "R" Circuit Low Each battery block voltage becomes less than 2.5 V (open) (1 trip detection)
·

Battery smart unit

·

HV battery


Comes on Master Warning Light:
Comes on
P308A-123 Hybrid Battery Voltage Sensor All Circuits Low Each battery block voltage becomes less than 2.5 V (open) (1 trip detection)
·

Battery smart unit

·

HV battery


Comes on Master Warning Light:
Comes on

CAUTION / NOTICE / HINT

CAUTION:
·

Before inspecting the high-voltage system, take safety precautions to prevent electrical shocks, such as wearing insulated gloves and removing the service plug grip. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·

After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>PRECAUTION

HINT:

At least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.


·

When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.



NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


PROCEDURE

1.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the intelligent tester to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / DTC.

Powertrain > Hybrid Control > Trouble Codes
50001 236

d.

Read the output DTCs.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>DTC CHECK / CLEAR

Result:
Result Proceed to
P0AFC-123 or P0A95-123 is not output. A
P0AFC-123 or P0A95-123 is also output. B



e.

Turn the power switch off.


f.

Disconnect the intelligent tester from the DLC3.



A

2.CHECK CONNECTOR CONNECTION CONDITION

B

2.CHECK CONNECTOR CONNECTION CONDITION
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the No. 2 hybrid vehicle battery shield panel.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>REMOVAL


c.
A258780E02
1.51,1.49 1.906,1.75 0.396,0.26 1.563,1.5 1.875,1.729 0.313,0.229 10 true z7

Check the connections of the z7 connector of the battery smart unit.

OK:

The connectors are connected securely and there are no contact problems.



d.

Install the No. 2 hybrid vehicle battery shield panel.


Result:
Proceed to
OK
NG



OK

3.REPLACE BATTERY SMART UNIT

NG

CONNECT SECURELY

3.REPLACE BATTERY SMART UNIT

NEXT

4.CLEAR DTC (HV)
4.CLEAR DTC (HV)
a.

Connect the intelligent tester to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / DTC.


d.

Clear the DTCs and freeze frame data.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>DTC CHECK / CLEAR

Powertrain > Hybrid Control > Clear DTCs
50002 236

e.

Perform a road test to charge and discharge the HV battery.


f.

Turn the power switch off.


g.

Disconnect the intelligent tester from the DLC3.


Result:
Proceed to
NEXT



NEXT

5.RECONFIRM DTC OUTPUT (HV)
5.RECONFIRM DTC OUTPUT (HV)
a.

Connect the intelligent tester to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / DTC.

Powertrain > Hybrid Control > Trouble Codes
50001 236

d.

Read the output DTCs.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>DTC CHECK / CLEAR

Result:
Result Proceed to
Hybrid battery voltage sensor circuit DTCs for this diagnostic procedure are not output A
Hybrid battery voltage sensor circuit DTCs for this diagnostic procedure are output B



e.

Turn the power switch off.


f.

Disconnect the intelligent tester from the DLC3.



A

RETURN TO NORMAL OPERATION

B