Refer to the description for DTC P0A80-123.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>P0A80-123
Values smaller than 2.0 V may not be shown in the Data List because a fail-safe value is substituted.
Hybrid battery voltage sensor in the DTC titles refers to the battery smart unit.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0B3D-123 | Hybrid Battery Voltage Sensor "A" Circuit Low | Each battery block voltage becomes less than 2.5 V (open) (1 trip detection) | ·
Battery smart unit ·
HV battery |
Comes on | Master Warning Light:
Comes on |
| P0B42-123 | Hybrid Battery Voltage Sensor "B" Circuit Low | Each battery block voltage becomes less than 2.5 V (open) (1 trip detection) | ·
Battery smart unit ·
HV battery |
Comes on | Master Warning Light:
Comes on |
| P0B47-123 | Hybrid Battery Voltage Sensor "C" Circuit Low | Each battery block voltage becomes less than 2.5 V (open) (1 trip detection) | ·
Battery smart unit ·
HV battery |
Comes on | Master Warning Light:
Comes on |
| P0B4C-123 | Hybrid Battery Voltage Sensor "D" Circuit Low | Each battery block voltage becomes less than 2.5 V (open) (1 trip detection) | ·
Battery smart unit ·
HV battery |
Comes on | Master Warning Light:
Comes on |
| P0B51-123 | Hybrid Battery Voltage Sensor "E" Circuit Low | Each battery block voltage becomes less than 2.5 V (open) (1 trip detection) | ·
Battery smart unit ·
HV battery |
Comes on | Master Warning Light:
Comes on |
| P0B56-123 | Hybrid Battery Voltage Sensor "F" Circuit Low | Each battery block voltage becomes less than 2.5 V (open) (1 trip detection) | ·
Battery smart unit ·
HV battery |
Comes on | Master Warning Light:
Comes on |
| P0B5B-123 | Hybrid Battery Voltage Sensor "G" Circuit Low | Each battery block voltage becomes less than 2.5 V (open) (1 trip detection) | ·
Battery smart unit ·
HV battery |
Comes on | Master Warning Light:
Comes on |
| P0B60-123 | Hybrid Battery Voltage Sensor "H" Circuit Low | Each battery block voltage becomes less than 2.5 V (open) (1 trip detection) | ·
Battery smart unit ·
HV battery |
Comes on | Master Warning Light:
Comes on |
| P0B65-123 | Hybrid Battery Voltage Sensor "I" Circuit Low | Each battery block voltage becomes less than 2.5 V (open) (1 trip detection) | ·
Battery smart unit ·
HV battery |
Comes on | Master Warning Light:
Comes on |
| P0B6A-123 | Hybrid Battery Voltage Sensor "J" Circuit Low | Each battery block voltage becomes less than 2.5 V (open) (1 trip detection) | ·
Battery smart unit ·
HV battery |
Comes on | Master Warning Light:
Comes on |
| P0B6F-123 | Hybrid Battery Voltage Sensor "K" Circuit Low | Each battery block voltage becomes less than 2.5 V (open) (1 trip detection) | ·
Battery smart unit ·
HV battery |
Comes on | Master Warning Light:
Comes on |
| P0B74-123 | Hybrid Battery Voltage Sensor "L" Circuit Low | Each battery block voltage becomes less than 2.5 V (open) (1 trip detection) | ·
Battery smart unit ·
HV battery |
Comes on | Master Warning Light:
Comes on |
| P0B79-123 | Hybrid Battery Voltage Sensor "M" Circuit Low | Each battery block voltage becomes less than 2.5 V (open) (1 trip detection) | ·
Battery smart unit ·
HV battery |
Comes on | Master Warning Light:
Comes on |
| P0B7E-123 | Hybrid Battery Voltage Sensor "N" Circuit Low | Each battery block voltage becomes less than 2.5 V (open) (1 trip detection) | ·
Battery smart unit ·
HV battery |
Comes on | Master Warning Light:
Comes on |
| P0B83-123 | Hybrid Battery Voltage Sensor "O" Circuit Low | Each battery block voltage becomes less than 2.5 V (open) (1 trip detection) | ·
Battery smart unit ·
HV battery |
Comes on | Master Warning Light:
Comes on |
| P0B88-123 | Hybrid Battery Voltage Sensor "P" Circuit Low | Each battery block voltage becomes less than 2.5 V (open) (1 trip detection) | ·
Battery smart unit ·
HV battery |
Comes on | Master Warning Light:
Comes on |
| P0B8D-123 | Hybrid Battery Voltage Sensor "Q" Circuit Low | Each battery block voltage becomes less than 2.5 V (open) (1 trip detection) | ·
Battery smart unit ·
HV battery |
Comes on | Master Warning Light:
Comes on |
| P0B92-123 | Hybrid Battery Voltage Sensor "R" Circuit Low | Each battery block voltage becomes less than 2.5 V (open) (1 trip detection) | ·
Battery smart unit ·
HV battery |
Comes on | Master Warning Light:
Comes on |
| P308A-123 | Hybrid Battery Voltage Sensor All Circuits Low | Each battery block voltage becomes less than 2.5 V (open) (1 trip detection) | ·
Battery smart unit ·
HV battery |
Comes on | Master Warning Light:
Comes on |
Before inspecting the high-voltage system, take safety precautions to prevent electrical shocks, such as wearing insulated gloves and removing the service plug grip. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>PRECAUTION
At least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Read the output DTCs.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>DTC CHECK / CLEAR
| Result | Proceed to |
|---|---|
| P0AFC-123 or P0A95-123 is not output. | A |
| P0AFC-123 or P0A95-123 is also output. | B |
Turn the power switch off.
Disconnect the intelligent tester from the DLC3.
A
B
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 2 hybrid vehicle battery shield panel.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>REMOVAL
Check the connections of the z7 connector of the battery smart unit.
The connectors are connected securely and there are no contact problems.
Install the No. 2 hybrid vehicle battery shield panel.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY SMART UNIT>COMPONENTS
| Proceed to |
|---|
| NEXT |
NEXT
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Clear the DTCs and freeze frame data.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>DTC CHECK / CLEAR
Perform a road test to charge and discharge the HV battery.
Turn the power switch off.
Disconnect the intelligent tester from the DLC3.
| Proceed to |
|---|
| NEXT |
NEXT
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Read the output DTCs.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>DTC CHECK / CLEAR
| Result | Proceed to |
|---|---|
| Hybrid battery voltage sensor circuit DTCs for this diagnostic procedure are not output | A |
| Hybrid battery voltage sensor circuit DTCs for this diagnostic procedure are output | B |
Turn the power switch off.
Disconnect the intelligent tester from the DLC3.
A
B