The inverter in the compressor with motor assembly outputs high-voltage to operate the motor. If there is an open or short in the output circuit, the ECU will stop compressor operation and store the DTC. The DTC will be stored as a history DTC. The compressor operation remains stopped until both the history and current DTCs are cleared.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B1472/72 | A/C Inverter High Voltage Output System Malfunction | Open or short in A/C inverter high voltage output system. | ·
Compressor with motor assembly ·
CAN communication system |
Memorised |
Wear electrically insulated gloves and pull out the service plug grip before inspection as procedures may require disconnecting high-voltage connectors. Be sure to carry the removed service plug grip because other workers may install it by mistake.
Do not touch the high-voltage connectors or terminals for 10 minutes after the service plug grip is removed.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
The hybrid control system and air conditioning system output DTCs separately. Inspect DTCs following the diagnosis procedure for the hybrid control system first if any DTCs from those systems are output simultaneously.
Using the intelligent tester to check if the CAN communication system is functioning normally.
| Result | Proceed to |
|---|---|
| CAN DTC is not output | A |
| CAN DTC is output | B |
A
B
Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM>HOW TO PROCEED WITH TROUBLESHOOTING