Refer to the description for DTC P0C73-776 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0C73-776).
If the water pump speed (measured value) signal is not sent to the power management control ECU when the power switch is on (READY), this DTC is stored.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P314A-828 | Inverter Coolant Pump Speed Signal | When either of the following conditions is met:
·
A malfunction in the power source circuit or water pump speed signal line of the inverter water pump assembly is detected. ·
A malfuncution in the power source circuit of the inverter water pump assembly or power management control ECU is detected. |
·
Wire harness or connector ·
Power management control ECU ·
Inverter water pump assembly ·
INV W/PMP fuse ·
INV W/PMP RLY fuse ·
INV W/PMP relay |
Comes on | Master Warning Light:
Comes on |
| DTC No. | Active Test |
|---|---|
| P314A-828 | Activate the Water Pump*1 |
*1: This is an Active Test of the inverter water pump assembly.
Refer to the wiring diagram for DTC P0C73-776 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0C73-776).
If DTC P0A78-284, 286, P0A7A-322, 324, P0A94-553 or 557 is output, replace the inverter with converter assembly after this inspection.
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the power switch on (READY) and wait for 2 minutes or more.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A09-265
| Proceed to |
|---|
| NEXT |
NEXT
Be sure to perform the inspection with the auxiliary battery voltage at 11 V or more.
When the auxiliary battery voltage is low, the inverter water pump assembly may not operate.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Active Test / Activate the Water Pump.
| Tester Display |
|---|
| Activate the Water Pump |
Perform the Activate the Water Pump Active Test.
Touch the inverter water pump assembly and check that it is operating (vibrating).
The inverter water pump is operating (vibrating).
Turn the power switch off.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0340-886
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0C73-776
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect connector A38 from the power management control ECU.
Disconnect connector A50 from the inverter water pump assembly.
Measure the resistance according to the value(s) in the table below.
| *a | Rear view of wire harness connector
(to Power Management Control ECU) |
*b | Front view of wire harness connector
(to Inverter Water Pump Assembly) |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A38-12 (NIWP) - A50-2 (NWP) | Power switch off | Below 1 Ω |
| A38-12 (NIWP) or A50-2 (NWP) -Body ground and other terminals | Power switch off | 10 kΩ or higher |
Connect the power management control ECU connector.
Connect the inverter water pump assembly connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect connector A50 from the inverter water pump assembly.
Turn the power switch on (IG).
| *a | Component with harness connected
(Power Management Control ECU) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A38-12 (NIWP) - I3-6 (E1) | Power switch on (IG) | 11 to 14 V |
Turn the power switch off.
Connect the inverter water pump assembly connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A09-265
| Proceed to |
|---|
| NEXT |
NEXT
Be sure to perform the inspection with the auxiliary battery voltage at 11 V or more.
When the auxiliary battery voltage is low, the inverter water pump assembly may not operate.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Active Test / Activate the Water Pump.
| Tester Display |
|---|
| Activate the Water Pump |
Perform the "Activate the Water Pump" Active Test.
| *a | Component with harness connected
(Power Management Control ECU) |
Connect an oscilloscope between the power management control ECU terminals specified in the table below, and measure the waveform.
| Item | Content |
|---|---|
| Terminal | A38-12 (NIWP) - I3-6 (E1) |
| Equipment Setting | 5 V/DIV., 100 ms./DIV. |
| Condition | Power switch on (IG), during Active Test |
The duration of wavelength is 300 msec or less.
Turn the power switch off.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0C73-776
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | No. 2 Engine Room Relay Block |
| *2 | INV W/PMP Relay |
Check installation condition of the INV W/PMP relay.
INV W/PMP relay is installed correctly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the IGCT relay and INV W/PMP relay from the No. 2 engine room relay block.
| *1 | No. 2 Engine Room Relay Block |
| *2 | INV W/PMP Relay |
| *3 | IGCT Relay |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 5 (IGCT relay) - 1 (INV W/PMP relay) | Power switch off | Below 1 Ω |
Do not apply excessive force when using the probes of the tester to perform the inspection. If excessive force is used, the holders will be damaged.
| *a | Example |
| *b | Shake Slightly |
| *c | Vibrate Slightly |
Connectors
Slightly shake the connector vertically and horizontally.
Wire Harness
Slightly shake the wire harness vertically and horizontally.
The connector joint and fulcrum of the vibration are the major areas that should be checked thoroughly.
No. 2 Engine Room Relay Block
Apply slight vibration with a finger to the No. 2 engine room relay block and check whether a malfunction occurs.
INV W/PMP RLY fuse
Apply slight vibration with a finger to the INV W/PMP RLY fuse and check whether a malfunction occurs.
Install the IGCT relay and INV W/PMP relay.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | No. 2 Engine Room Relay Block |
| *2 | INV W/PMP Relay |
Remove the INV W/PMP relay from the No. 2 engine room relay block.
| *1 | INV W/PMP Relay |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Auxiliary battery voltage is not applied between terminals 1 and 2 | 10 kΩ or higher |
| Auxiliary battery voltage is applied between terminals 1 and 2 | Below 1 Ω |
Install the INV W/PMP relay.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the A50 inverter water pump assembly connector.
| *a | Front view of wire harness connector
(to Inverter Water Pump Assembly) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A50-4 (+BWP) - Body ground | Power switch on (IG) | 11 to 14 V |
Turning the power switch on (IG) with the power management control ECU connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
| *a | Example |
| *b | Shake Slightly |
| *c | Vibrate Slightly |
Connectors
Slightly shake the connector vertically and horizontally.
Wire Harness
Slightly shake the wire harness vertically and horizontally.
The connector joint and fulcrum of the vibration are the major areas that should be checked thoroughly.
No. 2 Engine Room Relay Block
Apply slight vibration with a finger to the No. 2 engine room relay block and check whether a malfunction occurs.
INV W/PMP fuse
Apply slight vibration with a finger to the INV W/PMP fuse and check whether a malfunction occurs.
INV W/PMP relay
Apply slight vibration with a finger to the INV W/PMP relay and check whether a malfunction occurs.
Connect the inverter water pump assembly connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the A50 inverter water pump assembly connector.
| *a | Front view of wire harness connector
(to Inverter Water Pump Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A50-1 (GND) - Body ground | Power switch off | Below 1 Ω |
Connect the inverter water pump assembly connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | No. 2 Engine Room Relay Block |
| *2 | INV W/PMP Fuse |
Check installation condition of the INV W/PMP fuse.
INV W/PMP fuse is installed correctly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | No. 2 Engine Room Relay Block |
| *2 | INV W/PMP Relay |
Remove the INV W/PMP relay from the No. 2 engine room relay block.
| *1 | INV W/PMP Relay |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Auxiliary battery voltage is not applied between terminals 1 and 2 | 10 kΩ or higher |
| Auxiliary battery voltage is applied between terminals 1 and 2 | Below 1 Ω |
Install the INV W/PMP relay.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the INV W/PMP relay from the No. 2 engine room relay block.
Disconnect the A50 inverter water pump assembly connector.
Measure the resistance according to the value(s) in the table below.
| *1 | No. 2 Engine Room Relay Block | *2 | INV W/PMP Relay |
| *a | Front view of wire harness connector
(to Inverter Water Pump Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A50-4 (+BWP) - 3 (INV W/PMP relay) | Power switch off | Below 1 Ω |
| A50-4 (+BWP) or 3 (INV W/PMP relay) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
Do not apply excessive force when using the probes of the tester to perform the inspection. If excessive force is used, the holders will be damaged.
Install the INV W/PMP relay.
Connect the inverter water pump assembly connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | No. 2 Engine Room Relay Block |
| *2 | INV W/PMP Fuse |
Remove the INV W/PMP fuse from the No. 2 engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| INV W/PMP fuse | Always | Below 1 Ω |
Install the INV W/PMP fuse.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>WATER PUMP WITH MOTOR>COMPONENTS
| Proceed to |
|---|
| NEXT |
NEXT
Check the terminals of the INV W/PMP relay holder.
The terminals of the INV W/PMP relay holder are not bent, loose or corroded.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | No. 2 Engine Room Relay Block |
| *2 | INV W/PMP RLY Fuse |
Remove the INV W/PMP RLY fuse from the No. 2 engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| INV W/PMP RLY fuse | Always | Below 1 Ω |
Install the INV W/PMP RLY fuse.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| Proceed to |
|---|
| NEXT |
NEXT
Check the terminals of the INV W/PMP relay holder.
The terminals of the INV W/PMP relay holder are not bent, loose or corroded.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | No. 2 Engine Room Relay Block |
| *2 | INV W/PMP RLY Fuse |
Remove the INV W/PMP RLY fuse from the No. 2 engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| INV W/PMP RLY fuse | Always | Below 1 Ω |
Install the INV W/PMP RLY fuse.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT
| *1 | No. 2 Engine Room Relay Block |
| *2 | INV W/PMP RLY Fuse |
Check installation condition of the INV W/PMP RLY fuse.
INV W/PMP RLY fuse is installed correctly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | No. 2 Engine Room Relay Block |
| *2 | INV W/PMP RLY Fuse |
Remove the INV W/PMP RLY fuse from the No. 2 engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| INV W/PMP RLY fuse | Always | Below 1 Ω |
Install the INV W/PMP RLY fuse.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check the terminals of the INV W/PMP RLY fuse holder.
The terminals of the INV W/PMP RLY fuse holder are not bent, loose or corroded.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| Proceed to |
|---|
| NEXT |
NEXT
| *1 | No. 2 Engine Room Relay Block |
| *2 | INV W/PMP Relay |
Remove the INV W/PMP relay from the No. 2 engine room relay block.
| *1 | INV W/PMP Relay |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Auxiliary battery voltage is not applied between terminals 1 and 2 | 10 kΩ or higher |
| Auxiliary battery voltage is applied between terminals 1 and 2 | Below 1 Ω |
Install the INV W/PMP relay.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | No. 2 Engine Room Relay Block |
| *2 | INV W/PMP Relay |
Remove the INV W/PMP relay from the No. 2 engine room relay block.
| *1 | INV W/PMP Relay |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Auxiliary battery voltage is not applied between terminals 1 and 2 | 10 kΩ or higher |
| Auxiliary battery voltage is applied between terminals 1 and 2 | Below 1 Ω |
Install the INV W/PMP relay.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT