DTC P0A93-346 Inverter Cooling System Performance |

| *1 | Inverter Water Pump Assembly | *2 | Inverter Reserve Tank Assembly |
| *3 | Inverter with Converter Assembly | *4 | Radiator Assembly (HV) |
| *5 | Hybrid Vehicle Transaxle Assembly | - | - |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A93 | 346 | Inverter cooling system malfunction (HV cooling malfunction) HV cooling temperature increases and the temperature of any inverter with converter assembly related parts increases. (1 trip detection logic) |
|
| 1.CHECK VEHICLE CONDITION |
Make sure that the front side of the radiator grille is not blocked with anything.
Ask the customer if the front side of the radiator grille was blocked with anything.
| Result | Proceed to |
| Not blocked. | A |
| Is/was blocked. | B |
|
| ||||
| A | |
| 2.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
| P0A93-346 only is output. | A |
| Any of the following DTCs are also output. | B |
| DTC No. | Relevant Diagnosis |
| P0A02-719 | Motor Electronics Coolant Temperature Sensor Circuit Low |
| P0A03-720 | Motor Electronics Coolant Temperature Sensor Circuit High |
| P0C73-776 | Motor Electronics Coolant Pump "A" Control Performance |
| P314A-828 | Inverter Coolant Pump Speed Signal |
Turn the power switch off.
|
| ||||
| A | |
| 3.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR) |
Check that the service plug grip is not installed.
Check the connector connections and contact pressure of the low voltage connectors of the inverter with converter assembly (Click here).

|
| ||||
| OK | |
| 4.CHECK QUANTITY OF HV COOLANT |
Check the HV coolant level in the inverter reserve tank.
Check for HV coolant leaks.
| Result | Proceed to |
| No leaks are found and coolant level in the inverter reserve tank assembly is above the low line. | A |
| No leaks are found and coolant level in the inverter reserve tank assembly is below the low line. | B |
| HV coolant leaks are evident. | C |
|
| ||||
|
| ||||
| A | |
| 5.CHECK COOLANT HOSE |
Check if the hoses of the cooling system are kinked or clogged.
|
| ||||
| OK | |
| 6.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (CONTROL THE ELECTRIC COOLING FAN) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Electric Cooling Fan.
Perform the "Control the Electric Cooling Fan" Active Test.
Turn the power switch off.
|
| ||||
| OK | |
| 7.READ VALUE USING INTELLIGENT TESTER (DATA LIST) |
Turn the power switch off and leave the vehicle for at least 1 hour.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Data List / Inverter Coolant Water Temperature, Inverter Temp (MG2), Cnv Tmp (Upper), Cnv Temp (Lower), Inverter Temp (MG1).
Read the Data List.
| Result | Proceed to |
| Other than below. | A |
| "Inverter Coolant Water Temperature" value is higher than the displayed temperature of any other Data List item by 20°C (36°F) or more. | B |
Turn the power switch off.
|
| ||||
| A | |
| 8.CHECK HV COOLANT (CHECK FOR CONDITIONS THAT MAY HAVE CAUSED FREEZING) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Read the freeze frame data Ambient Temperature using the intelligent tester.
Check if the freeze frame data Ambient Temperature is below freezing.
| Result | Proceed to |
| Ambient Temperature value is below freezing temperature of the HV coolant. | A |
| Ambient Temperature value is above freezing temperature of the HV coolant. | B |
Turn the power switch off.
|
| ||||
| A | |
| 9.REPLACE HV COOLANT |
Replace the HV coolant with coolant having an appropriate concentration (appropriate freeze point) for the vehicle usage conditions (Click here).
| NEXT | ||
| ||