Home › Engine / Hybrid System · 6AR-FSE › ENGINE CONTROL › SFI SYSTEM

DTC    P05042B    Brake Switch "A"/"B" Signal Cross Coupled

for Preparation Click here


DESCRIPTION

The stop light switch assembly is a duplex system that transmits two signals: STP and ST1-. These two signals are used by the ECM to monitor whether or not the brake system is working properly. If the signals, which indicate the brake pedal is being depressed and released, are detected simultaneously, the ECM interprets this as a malfunction in the stop light switch assembly and stores the DTC.

HINT:
The normal signal conditions are as shown in the table below.

Signal (ECM Terminal)
Brake Pedal Released
In Transition
Brake Pedal Depressed
STP
OFF
ON
ON
ST1-
ON
ON
OFF
  1. [OFF] denotes ground potential.
  2. [ON] denotes battery potential (+B).
On the GTS, Data List item Stop Light SW is ON when the brake pedal depressed.


DTC No.
DTC Detection Condition
Trouble Area
P05042B
Conditions (a) and (b) continue for 0.5 seconds or more (1 trip detection logic):
(a) Engine switch on (IG).
(b) STP signal off when ST1- signal off.
  1. Open or short in stop light switch signal circuit
  2. Stop light switch assembly
  3. No. 1 integration relay
  4. ECM

WIRING DIAGRAM


A340664E01


INSPECTION PROCEDURE

NOTICE:
Inspect the fuses for circuits related to this system before performing the following procedure.

HINT:
  1. Read freeze frame data using the GTS. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.
  2. Stop light switch assembly conditions can be checked using the GTS.
    1. Connect the GTS to the DLC3.
    2. Turn the engine switch on (IG).
    3. Turn the GTS on.
    4. Enter the following menus: Powertrain / Engine / Data List / All Data / Stop Light SW.
    5. Check the Data List indication when the brake pedal is depressed and released.

      Brake Pedal Operation
      Stop Light SW
      Depressed
      ON
      Released
      OFF

1.CHECK TERMINAL VOLTAGE (POWER SOURCE OF STOP LIGHT SWITCH ASSEMBLY)


    A312702E01
  1. Disconnect the stop light switch assembly connector.
    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Stop Light Switch Assembly)

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    A77-1 (B) - Body ground
    Always
    11 to 14 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (BATTERY - STOP LIGHT SWITCH ASSEMBLY)
OK


2.CHECK TERMINAL VOLTAGE (POWER SOURCE OF STOP LIGHT SWITCH ASSEMBLY)


    A312702E02
  1. Disconnect the stop light switch assembly connector.
    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Stop Light Switch Assembly)

  1. Turn the engine switch on (IG).

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    A77-5 (B) - Body ground
    Engine switch on (IG)
    11 to 14 V



NG
Go to step 6
OK


3.CHECK HARNESS AND CONNECTOR (STOP LIGHT SWITCH ASSEMBLY - BODY GROUND)
  1. Disconnect the stop light switch assembly connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:

    Tester Connection
    Condition
    Specified Condition
    A77-3 (GND) - Body ground
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


4.CHECK TERMINAL VOLTAGE (STP AND ST1- VOLTAGE)


  1. Disconnect the ECM connector.


    A256080E21


    Text in Illustration 
    *a
    Brake Pedal Depressed
    *b
    Brake Pedal Released
    *c
    Front view of wire harness connector
    (to ECM)
    -
    -

  1. Turn the engine switch on (IG).

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:

    Tester Connection
    Condition
    Specified Condition
    A84-10 (ST1-) - Body ground
    Brake pedal released
    7.5 to 14 V
    Brake pedal depressed
    Below 1.5 V
    A84-9 (STP) - Body ground
    Brake pedal released
    Below 1.5 V
    Brake pedal depressed
    7.5 to 14 V



NG
Go to step 5
OK

REPLACE ECM (Click here)  

5.CHECK HARNESS AND CONNECTOR (STOP LIGHT SWITCH ASSEMBLY - ECM)
  1. Disconnect the stop light switch assembly connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:

    Tester Connection
    Condition
    Specified Condition
    A77-2 (OUT) - A84-9 (STP)
    Always
    Below 1 Ω
    A77-4 (L) - A84-10 (ST1-)
    Always
    Below 1 Ω
    A77-2 (OUT) or A84-9 (STP) - Body ground and other terminals
    Always
    10 kΩ or higher
    A77-4 (L) or A84-10 (ST1-) - Body ground and other terminals
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE STOP LIGHT SWITCH ASSEMBLY (Click here)  

6.CHECK HARNESS AND CONNECTOR (NO. 1 INTEGRATION RELAY - STOP LIGHT SWITCH ASSEMBLY)
  1. Disconnect the stop light switch assembly connector.

  1. Disconnect the No. 1 integration relay connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:

    Tester Connection
    Condition
    Specified Condition
    1C-2 - A77-5 (B)
    Always
    Below 1 Ω
    1C-2 or A77-5 (B) - Body ground and other terminals
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE NO. 1 INTEGRATION RELAY (Click here)