The combination meter assembly receives signals from this circuit to adjust the illumination of the combination meter assembly. The combination meter assembly sets the illumination level based on the user operation of the light control rheostat switch (trip switch).
When replacing the combination meter assembly, always replace it with a new one. If a combination meter assembly which was installed to another vehicle is used, the information stored in it will not match the information from the vehicle and a DTC may be stored.
Before replacing the main body ECU (multiplex network body ECU), refer to Service Bulletin.*1
The vehicle battery supplies power to the main body ECU (multiplex network body ECU) via the door control battery. Therefore, before performing this troubleshooting procedure, make sure to perform an on-vehicle inspection to confirm that the main body ECU (multiplex network body ECU) power source circuit is normal.*2
Click hereVehicle Interior>DOOR LOCK>POWER DOOR LOCK CONTROL SYSTEM>ON-VEHICLE INSPECTION
*1: w/ Smart Entry and Start System
*2: w/ Door Control Battery
The meter illumination dims when the taillights are turned on.
Setting the meter illumination level to maximum brightness cancels the above dimming of the meter illumination.
Setting the meter illumination level to minimum brightness turns off the meter illumination.
The automatic light control sensor sensitivity can be customized.
Check if CAN communication DTCs are output.
Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM>DIAGNOSIS SYSTEM
| Result | Proceed to |
|---|---|
| DTCs are not output | A |
| DTCs are output | B |
A
B
Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM>HOW TO PROCEED WITH TROUBLESHOOTING
Check if lighting system DTCs are output.
| Result | Proceed to |
|---|---|
| DTC B1244 is not output | A |
| DTC B1244 is output | B |
A
B
Replace the combination meter assembly with a new one.
Click hereVehicle Interior>METER / GAUGE / DISPLAY>COMBINATION METER>REMOVAL
The operation of the combination meter assembly returns to normal.
| Proceed to |
|---|
| OK |
| NG |
OK