The combination meter assembly receives signals through this circuit to adjust the illumination of the combination meter assembly. The combination meter assembly sets the illumination level based on the user operation of the light control rheostat switch in the trip switch.
When replacing the combination meter assembly, always replace it with a new one. If a combination meter assembly which was installed to another vehicle is used, the information stored in it will not match the information from the vehicle and a DTC may be stored.
The illumination level of the combination meter assembly can be adjusted by pressing the light control rheostat switch (trip switch).
The illumination of the combination meter assembly dims when the taillights are turned on.
Setting the illumination to maximum brightness cancels the above dimming of the illumination.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Combination Meter / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Light Control Switch (UP) | Light control rheostat up switch (Trip switch) | OFF or ON | OFF: Switch released
ON: Switch pushed |
- |
| Light Control Switch (DOWN) | Light control rheostat down switch (Trip switch) | OFF or ON | OFF: Switch released
ON: Switch pushed |
- |
| Tester Display |
|---|
| Light Control Switch (UP) |
| Light Control Switch (DOWN) |
Light control rheostat up or down switch condition displayed on the GTS changes with the actual switch operation.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the trip switch.
Click hereVehicle Interior>METER / GAUGE / DISPLAY>TRIP SWITCH>REMOVAL
Inspect the trip switch.
Click hereVehicle Interior>METER / GAUGE / DISPLAY>TRIP SWITCH>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the K20 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| K111-4 (RV) - K20-2 (TR) | Always | Below 1 Ω |
| K111-1 (E) - K20-5 (SW3) | Always | Below 1 Ω |
| K111-4 (RV) or K20-2 (TR) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG