Home › Engine / Hybrid System › 2AR-FE (ENGINE CONTROL) › SFI SYSTEM › 2017.09–2021.02
RM33A0E _51 Engine / Hybrid System _065323 2AR-FE ENGINE CONTROL _0329559 SFI SYSTEM C

2AR-FE ENGINE CONTROL  SFI SYSTEM  P0660  Intake Manifold Tuning Valve Control Circuit / Open (Bank 1)  


DESCRIPTION

This circuit opens and closes the Intake Air Control Valve (IACV) in response to changes in the engine load in order to increase the intake efficiency (ACIS: Acoustic Control Induction System).

A255384C03
3.99,0.24 4.302,0.438 0.313,0.198 10 false *a 6.083,0.24 6.396,0.438 0.313,0.198 10 false *b
*a Intake Air Control Valve Open *b Intake Air Control Valve Closed


DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P0660 Intake Manifold Tuning Valve Control Circuit / Open (Bank 1) The following conditions are met simultaneously for 0.5 seconds or more (2 trip detection logic):
·

The voltage of terminal ACIS of the ECM is low when the vacuum switching valve assembly (for acoustic control induction system) is off.

·

The engine has been started.


·

Open or short in vacuum switching valve assembly (for acoustic control induction system) circuit

·

Vacuum switching valve assembly (for acoustic control induction system)

·

ECM


Comes on DTC stored

WIRING DIAGRAM

A412778E01
0.677,2.635 1.375,2.938 0.698,0.302 10 false Battery 0.521,1.938 1.323,2.198 0.802,0.26 10 false FL MAIN 1.802,1.448 2.979,1.833 1.177,0.385 10 false EFI-MAIN NO. 1 0.469,0.927 1.938,1.292 1.469,0.365 10 false EFI-MAIN NO. 1 2.938,0.906 3.719,1.271 0.781,0.365 10 false EFI NO. 1 4.99,0.938 5.146,1.135 0.156,0.198 10 false 1 3.854,0.958 4.01,1.156 0.156,0.198 10 false 2 1.781,0.646 1.938,0.844 0.156,0.198 10 false 3 2.583,0.604 2.74,0.802 0.156,0.198 10 false 5 1.802,0.99 1.958,1.188 0.156,0.198 10 false 1 2.604,0.979 2.76,1.177 0.156,0.198 10 false 2 4.094,0.938 4.406,1.135 0.313,0.198 10 false +B 4.563,0.948 5.177,1.146 0.615,0.198 10 false ACIS 3.656,1.438 4.115,1.635 0.458,0.198 10 false C85 3.948,1.448 5.552,2.094 1.604,0.646 10 false Vacuum Switching Valve Assembly (for Acoustic Control Induction System) 5.396,1.063 5.854,1.26 0.458,0.198 10 false C58 5.458,0.865 5.771,1.063 0.313,0.198 10 false 32 5.76,0.896 6.375,1.094 0.615,0.198 10 false ACIS 5.406,2.833 5.865,3.031 0.458,0.198 10 false A22 5.458,2.656 5.771,2.854 0.313,0.198 10 false 46 5.792,2.719 6.406,2.917 0.615,0.198 10 false MREL 6.156,3.281 6.615,3.479 0.458,0.198 10 false ECM

CAUTION / NOTICE / HINT

NOTICE:

Inspect the fuses for circuits related to this system before performing the following procedure.


HINT:

Read Freeze Frame Data using the GTS. The ECM records vehicle and driving condition information as Freeze Frame Data the moment a DTC is stored. When troubleshooting, Freeze Frame Data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.


PROCEDURE

1.PERFORM ACTIVE TEST USING GTS (ACTIVE THE VSV FOR INTAKE CONTROL)
A204525C03
0.405,0.02 1.096,0.198 0.691,0.178 10 *a 2.044,0.02 2.796,0.213 0.752,0.193 10 *b 0.766,0.595 0.96,0.764 0.194,0.169 10 *c 0.87,1.792 1.076,1.96 0.206,0.168 10 *2 0.119,1.649 0.298,1.824 0.179,0.175 10 *1 2.211,0.657 2.407,0.829 0.196,0.172 10 *c 0.485,1.461 0.317,1.645 false 0.686,1.35 0.941,1.784 false 2.342,1.815 2.548,1.983 0.206,0.168 10 *2 1.591,1.672 1.77,1.847 0.179,0.175 10 *1 1.957,1.484 1.79,1.668 false 2.159,1.373 2.414,1.807 false
*1 Port F
*2 Port E
*a ON
*b OFF
*c Air


a.

Disconnect the vacuum hose from port F on the vacuum switching valve assembly (for acoustic control induction system).


b.

Connect the GTS to the DLC3.


c.

Turn the ignition switch to ON.


d.

Turn the GTS on.


e.

Enter the following menus: Powertrain / Engine and ECT / Active Test / Activate the VSV for Intake Control.

Powertrain > Engine and ECT > Active Test
Tester Display
Activate the VSV for Intake Control
50004 234 3

f.

Operate the vacuum switching valve assembly (for acoustic control induction system) check the air flow.

Standard:
Activate the VSV for Intake Control Specified Condition
ON Air from port E flows out through port F
OFF Air from port E flows out through air filter


HINT:

Jiggle the wire harness and connector to increase the likelihood of detecting malfunctions that do not always occur.



Result:
Proceed to
OK
NG



OK

NG

2.INSPECT VACUUM SWITCHING VALVE ASSEMBLY (FOR ACOUSTIC CONTROL INDUCTION SYSTEM)
2.INSPECT VACUUM SWITCHING VALVE ASSEMBLY (FOR ACOUSTIC CONTROL INDUCTION SYSTEM)
a.

Inspect the vacuum switching valve assembly (for acoustic control induction system).

Click hereEngine / Hybrid System>2AR-FE (INTAKE / EXHAUST)>VACUUM SWITCHING VALVE (for ACIS)>INSPECTION


Result:
Proceed to
OK
NG



OK

3.CHECK TERMINAL VOLTAGE (POWER SOURCE OF VACUUM SWITCHING VALVE ASSEMBLY (FOR ACOUSTIC CONTROL INDUCTION SYSTEM))

NG

REPLACE VACUUM SWITCHING VALVE ASSEMBLY (FOR ACOUSTIC CONTROL INDUCTION SYSTEM)

3.CHECK TERMINAL VOLTAGE (POWER SOURCE OF VACUUM SWITCHING VALVE ASSEMBLY (FOR ACOUSTIC CONTROL INDUCTION SYSTEM))
A399949C10
0.781,0.979 1.198,1.313 0.417,0.333 2.51,1.802 1.979,1.271 true 0.854,1.042 1.25,1.333 0.396,0.292 10 false C85 0.198,0.198 0.51,0.396 0.313,0.198 10 false *a 2.479,1.854 2.813,2.167 0.333,0.313 10 false +B
*a Front view of wire harness connector (to Vacuum Switching Valve Assembly (for Acoustic Control Induction System))


a.

Disconnect the vacuum switching valve assembly (for acoustic control induction system) connector.


b.

Turn the ignition switch to ON.


c.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
C85-2 (+B) - Body ground Ignition switch ON 11 to 14 V



Result:
Proceed to
OK
NG



OK

4.CHECK HARNESS AND CONNECTOR (VACUUM SWITCHING VALVE ASSEMBLY (FOR ACOUSTIC CONTROL INDUCTION SYSTEM) - ECM)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR (EFI-MAIN NO.1 RELAY - VACUUM SWITCHING VALVE ASSEMBLY (FOR ACOUSTIC CONTROL INDUCTION SYSTEM))

4.CHECK HARNESS AND CONNECTOR (VACUUM SWITCHING VALVE ASSEMBLY (FOR ACOUSTIC CONTROL INDUCTION SYSTEM) - ECM)
a.

Disconnect the vacuum switching valve assembly (for acoustic control induction system) connector.


b.

Disconnect the ECM connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C85-1 (ACIS) - C58-32 (ACIS) Always Below 1 Ω
C85-1 (ACIS) or C58-32 (ACIS) - Body ground and other terminals Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR