In this circuit, the compressor assembly with pulley (compressor solenoid) receives refrigerant compression demand signals from the air conditioning amplifier assembly.
Based on this signal, the compressor assembly with pulley (compressor solenoid) changes the amount of compressor output.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B1451 | Compressor Solenoid Circuit | Open or short in compressor solenoid circuit | ·
Compressor assembly with pulley (compressor solenoid) ·
Harness or connector ·
Air conditioning amplifier assembly |
- |
for 2AR-FE
for A25A-FKS
| Result | Proceed to |
|---|---|
| for 2AR-FE | A |
| for A25A-FKS | B |
A
B
| *a | Front view of wire harness connector
(to Compressor Assembly with Pulley (Compressor Solenoid)) |
Disconnect the C62 compressor assembly with pulley (compressor solenoid) connector.
Using an oscilloscope, check the waveform.
| Item | Content |
|---|---|
| Terminal No. | C62-2 (SOL+) - Body ground |
| Tool Setting | 5 V/DIV., 500 μs./DIV. |
| Condition | ·
Engine running ·
Blower switch: LO ·
A/C switch: On |
Waveform is similar to that shown in the illustration.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the K54 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C62-2 (SOL+) - K54-3 (SOL+) | Always | Below 1 Ω |
| C62-2 (SOL+) or K54-3 (SOL+) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to Compressor Assembly with Pulley (Compressor Solenoid)) |
Disconnect the C98 compressor assembly with pulley (compressor solenoid) connector.
Using an oscilloscope, check the waveform.
| Item | Content |
|---|---|
| Terminal No. | C98-2 (SOL+) - Body ground |
| Tool Setting | 5 V/DIV., 500 μs./DIV. |
| Condition | ·
Engine running ·
Blower switch: LO ·
A/C switch: On |
Waveform is similar to that shown in the illustration.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the K54 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C98-2 (SOL+) - K54-3 (SOL+) | Always | Below 1 Ω |
| C98-2 (SOL+) or K54-3 (SOL+) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG