Home › Power Source / Network › 2GR-FKS (BATTERY / CHARGING) › GENERATOR › 2018.04–2021.02
RM33A0E _57 Power Source / Network _065340 2GR-FKS BATTERY / CHARGING _0328814 GENERATOR A

2GR-FKS BATTERY / CHARGING  GENERATOR  REMOVAL  


CAUTION / NOTICE / HINT

The necessary procedures (adjustment, calibration, initialization or registration) that must be performed after parts are removed and installed, or replaced during generator assembly removal/installation are shown below.

Necessary Procedures After Parts Removed/Installed/Replaced
Replaced Part or Performed Procedure Necessary Procedure Effect/Inoperative Function when Necessary Procedure not Performed Link
Battery terminal is disconnected/reconnected Perform steering sensor zero point calibration Lane departure alert system (w/ Steering Control) (Click here)
Pre-collision system
Memorize steering angle neutral point Parking assist monitor system (Click here)
Panoramic view monitor system (Click here)

PROCEDURE

Hide 1. PRECAUTION

NOTICE:

After turning the engine switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


Hide 2.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION


Hide 16400 3.REMOVE RADIATOR ASSEMBLY

Hide 11209 4.REMOVE V-BANK COVER SUB-ASSEMBLY

Hide 16361A 5.REMOVE V-RIBBED BELT

Hide 27020 6.REMOVE GENERATOR ASSEMBLY

a.
A407333

Open the terminal cap.


b.

Remove the nut and disconnect the wire harness from terminal B.


c.

Remove the 2 bolts.


d.
A407334

Disconnect the generator assembly connector.


e.

Disconnect the compressor assembly with magnetic clutch connector.


f.

Disconnect the camshaft timing oil control solenoid assembly connector.


g.

Disengage the 3 wire harness clamps and remove the wire harness clamp bracket.


h.
A407335

Remove the 2 bolts and generator assembly bracket.


i.
A407336

Remove the 2 bolts and generator assembly.