Home › Power Source / Network › A25A-FKS (BATTERY / CHARGING) › GENERATOR (for 150 A Type) › from 2021.02
RM33A0E _57 Power Source / Network _065349 A25A-FKS BATTERY / CHARGING _0462232 GENERATOR(for 150 A Type) A

A25A-FKS BATTERY / CHARGING  GENERATOR(for 150 A Type)  REMOVAL  


CAUTION / NOTICE / HINT

The necessary procedures (adjustment, calibration, initialization or registration) that must be performed after parts are removed and installed, or replaced during generator assembly removal/installation are shown below.

Necessary Procedures After Parts Removed/Installed/Replaced
Replaced Part or Performed Procedure Necessary Procedure Effect/Inoperative Function when Necessary Procedure not Performed Link
Battery terminal is disconnected/reconnected Perform steering sensor zero point calibration Lane Tracing Assist System (Click here)
Pre-collision system
Memorize steering angle neutral point Parking assist monitor system (Click here)
Panoramic View Monitor System (Click here)

NOTICE:

This procedure includes the removal of small-head bolts. Refer to Small-Head Bolts of Basic Repair Hint to identify the small-head bolts.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


PROCEDURE

Hide 1. PRECAUTION

NOTICE:

After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


Hide 2.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

Hide 53295E 3.REMOVE COOL AIR INTAKE DUCT SEAL

Hide 17750A 4.REMOVE INLET AIR CLEANER ASSEMBLY

Hide 89421 5.REMOVE E.F.I. VACUUM SENSOR ASSEMBLY (MANIFOLD ABSOLUTE PRESSURE SENSOR)

Hide 6.REMOVE V-RIBBED BELT

Hide 27020 7.REMOVE GENERATOR ASSEMBLY

a.
A402154

Disconnect the generator assembly connector.


b.

Open the terminal cap.


c.

Remove the nut and disconnect the wire harness from terminal B.


d.

Remove the bolt and separate the wire harness clamp bracket from the generator assembly.


e.
A402155

Remove the 2 nuts and loosen the bolt.


f.

Using an E8 "TORX" socket wrench, remove the 2 stud bolts.


g.

Remove the bolt and generator assembly.