Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM › 2017.09–2018.04
RM33C0E _58 Vehicle Interior _065464 HEATING / AIR CONDITIONING _0329891 AIR CONDITIONING SYSTEM C

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  B1442  Air Inlet Damper Control Servo Motor Circuit  


DESCRIPTION

The No. 1 blower damper servo sub-assembly sends pulse signals to inform the air conditioning amplifier assembly of the damper position. The air conditioning amplifier assembly activates the motor (normal or reverse) based on these signals to move the air inlet damper to the appropriate position to change the air inlet mode (fresh, recirculation/fresh, and recirculation).

The air conditioning amplifier assembly communicates with the servo through a communication/driver IC and wiring assembly called the air conditioning harness assembly.

DTC No. Detection Item DTC Detection Condition Trouble Area Memory
B1442 Air Inlet Damper Control Servo Motor Circuit Air inlet damper position sensor value does not change even if air conditioning amplifier assembly operates No. 1 blower damper servo sub-assembly
·

No. 1 blower damper servo sub-assembly

·

No. 1 air conditioning radiator damper servo sub-assembly

·

Air conditioning harness assembly

·

Air conditioning amplifier assembly

·

Blower assembly


Memorized
(30 sec. or more)*

*: The air conditioning amplifier assembly stores this DTC if the malfunction has occurred for the period of time indicated in the brackets.


DTC Detection Condition Combination Table
Vehicle Condition
Pattern 1 Pattern 2
Diagnosis Condition No. 1 blower damper servo sub-assembly operating ○ ○
Malfunction Air inlet damper servo operation request signals are output but the air inlet damper position sensor value does not change ○ -
Air inlet damper servo operation request signals are output but the air inlet damper position sensor value is abnormal - ○
Detection Time Continuously for 30 seconds or more Continuously for 30 seconds or more
Trip Count 1 trip 1 trip

HINT:

If the conditions of either of these patterns are detected, a DTC will be stored.


WIRING DIAGRAM

for LHD


E379772E08
0.604,1.594 1.969,1.781 1.365,0.188 10 false Driver Side Air Mix 0.198,3.583 2.208,3.854 2.01,0.271 10 false Front Passenger Side Mode*1 0.198,5.563 2.198,5.75 2,0.188 10 false Front Passenger Side Air Mix 6.646,0.438 6.938,0.615 0.292,0.177 10 false +B 6.771,1.469 7.063,1.646 0.292,0.177 10 false IC 2.49,2.854 2.781,3.031 0.292,0.177 10 false IC 2.792,4.833 3.229,5.01 0.438,0.177 10 false STE2 2.792,5.031 3.229,5.208 0.438,0.177 10 false STE1 2.948,5.25 3.229,5.448 0.281,0.198 10 false M- 2.938,5.542 3.219,5.74 0.281,0.198 10 false M+ 2.844,5.729 3.188,5.896 0.344,0.167 10 false GND 3.24,4.74 3.417,4.906 0.177,0.167 10 false 6 3.24,4.948 3.406,5.167 0.167,0.219 10 false 5 3.24,5.146 3.406,5.365 0.167,0.219 10 false 8 3.24,5.542 3.406,5.76 0.167,0.219 10 false 7 3.24,5.729 3.406,5.948 0.167,0.219 10 false 4 2.813,7.333 3.156,7.5 0.344,0.167 10 false GND 2.906,7.542 3.188,7.74 0.281,0.198 10 false M+ 2.917,7.729 3.198,7.927 0.281,0.198 10 false M- 2.813,7.917 3.177,8.115 0.365,0.198 10 false sigA 2.823,8.115 3.188,8.313 0.365,0.198 10 false sigB 3.229,7.323 3.396,7.542 0.167,0.219 10 false 1 3.229,7.531 3.396,7.75 0.167,0.219 10 false 4 3.229,7.74 3.396,7.958 0.167,0.219 10 false 5 3.229,7.938 3.396,8.156 0.167,0.219 10 false 2 3.229,8.135 3.396,8.354 0.167,0.219 10 false 3 0.229,6.448 3.01,6.813 2.781,0.365 10 false No. 1 Air Conditioning Radiator Damper Servo Sub-assembly 0.229,6.292 0.385,6.458 0.156,0.167 10 false A 0.25,8.708 2.865,8.917 2.615,0.208 10 false No. 1 Blower Damper Servo Sub-assembly 0.25,8.552 0.406,8.719 0.156,0.167 10 false B 3.573,8.542 5.094,8.875 1.521,0.333 10 false Air Conditioning Harness Assembly 5.531,8.552 7.083,8.885 1.552,0.333 10 false Air Conditioning Amplifier Assembly 3.542,9.198 4.958,9.417 1.417,0.219 10 false *1: for 3 Zone Type 3.542,9.469 5.156,9.708 1.615,0.24 10 false *2: except 3 Zone Type 0.656,9.531 2.292,9.719 1.635,0.188 10 false : LIN Communication Line 0.927,3.865 1.552,4.115 0.625,0.25 10 false Mode*2


for RHD


E379772E09
0.563,5.573 1.927,5.76 1.365,0.188 10 false Driver Side Air Mix 0.635,3.583 1.865,3.802 1.229,0.219 10 false Driver Side Mode 0.271,1.594 2.271,1.781 2,0.188 10 false Front Passenger Side Air Mix 6.646,0.438 6.938,0.615 0.292,0.177 10 false +B 6.771,1.469 7.063,1.646 0.292,0.177 10 false IC 2.49,2.854 2.781,3.031 0.292,0.177 10 false IC 2.792,4.833 3.229,5.01 0.438,0.177 10 false STE2 2.792,5.031 3.229,5.208 0.438,0.177 10 false STE1 2.948,5.25 3.229,5.448 0.281,0.198 10 false M- 2.938,5.542 3.219,5.74 0.281,0.198 10 false M+ 2.844,5.729 3.188,5.896 0.344,0.167 10 false GND 3.24,4.74 3.417,4.906 0.177,0.167 10 false 6 3.24,4.948 3.406,5.167 0.167,0.219 10 false 5 3.24,5.146 3.406,5.365 0.167,0.219 10 false 8 3.24,5.542 3.406,5.76 0.167,0.219 10 false 7 3.24,5.729 3.406,5.948 0.167,0.219 10 false 4 2.813,7.333 3.156,7.5 0.344,0.167 10 false GND 2.906,7.542 3.188,7.74 0.281,0.198 10 false M+ 2.917,7.729 3.198,7.927 0.281,0.198 10 false M- 2.813,7.917 3.177,8.115 0.365,0.198 10 false sigA 2.823,8.115 3.188,8.313 0.365,0.198 10 false sigB 3.229,7.323 3.396,7.542 0.167,0.219 10 false 1 3.229,7.531 3.396,7.75 0.167,0.219 10 false 4 3.229,7.74 3.396,7.958 0.167,0.219 10 false 5 3.229,7.938 3.396,8.156 0.167,0.219 10 false 2 3.229,8.135 3.396,8.354 0.167,0.219 10 false 3 0.229,6.448 3.01,6.813 2.781,0.365 10 false No. 1 Air Conditioning Radiator Damper Servo Sub-assembly 0.229,6.292 0.385,6.458 0.156,0.167 10 false A 0.25,8.708 2.865,8.917 2.615,0.208 10 false No. 1 Blower Damper Servo Sub-assembly 0.25,8.552 0.406,8.719 0.156,0.167 10 false B 3.573,8.542 5.094,8.875 1.521,0.333 10 false Air Conditioning Harness Assembly 5.531,8.552 7.083,8.885 1.552,0.333 10 false Air Conditioning Amplifier Assembly 0.656,9.531 2.292,9.719 1.635,0.188 10 false : LIN Communication Line


CAUTION / NOTICE / HINT

HINT:
·

Confirm that no mechanical problems are present because this DTC can be stored when either a damper link or damper is mechanically locked.

·

When installing a damper servo motor, make sure to install it correctly.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>BLOWER UNIT>REASSEMBLY

·

After replacing a damper servo motor, make sure to perform Servo Motor Initialization.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM>INITIALIZATION



PROCEDURE

1.CONFIRM MODEL
a.

Choose the model to be inspected.


Result:
Result Proceed to
for LHD (for 3 Zone Type) A
for LHD (except 3 Zone Type) B
for RHD C



A

2.CHECK FOR DTC

B

3.CHECK FOR DTC

C

4.CHECK FOR DTC
2.CHECK FOR DTC
a.

Check for DTCs.

Body Electrical > Air Conditioner > Trouble Codes
50001 121

Result:
Result Proceed to
Only B1497 is output A
B1441, B1442, B1446 and B1448 are output B
Only B1442 is output C



A

B

REPLACE NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY

C

5.INSPECT NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY (INSTALLATION CONDITION)
3.CHECK FOR DTC
a.

Check for DTCs.

Body Electrical > Air Conditioner > Trouble Codes
50001 121

Result:
Result Proceed to
Only B1497 is output A
B1441, B1442, B1443 and B1446 are output B
Only B1442 is output C



A

B

REPLACE NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY

C

5.INSPECT NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY (INSTALLATION CONDITION)
4.CHECK FOR DTC
a.

Check for DTCs.

Body Electrical > Air Conditioner > Trouble Codes
50001 121

Result:
Result Proceed to
Only B1497 is output A
B1441, B1442, B1443 and B1446 are output B
Only B1442 is output C



A

B

REPLACE NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY

C

5.INSPECT NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY (INSTALLATION CONDITION)
5.INSPECT NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY (INSTALLATION CONDITION)
a.

Check that the No. 1 blower damper servo sub-assembly is installed correctly.

OK:

The No. 1 blower damper servo sub-assembly is installed correctly.



Result:
Proceed to
OK
NG



OK

6.INSPECT NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY (MOTOR, LINK, DAMPER)

NG

INSTALL NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY CORRECTLY

6.INSPECT NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY (MOTOR, LINK, DAMPER)
a.

Check for a wire harness caught between the links of the motors and dampers.

OK:

No wire harnesses are caught between the links of the motors and dampers.



Result:
Proceed to
OK
NG



OK

7.INSPECT NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY (DAMPER)

NG

REMOVE PINCHED WIRE HARNESS

7.INSPECT NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY (DAMPER)
a.

Remove the No. 1 blower damper servo sub-assembly.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>BLOWER UNIT>DISASSEMBLY


b.

Operate the air inlet dampers by hand.

OK:

The air inlet dampers are easily operated by hand.



Result:
Proceed to
OK
NG



OK

8.INSPECT AIR CONDITIONING HARNESS ASSEMBLY

NG

8.INSPECT AIR CONDITIONING HARNESS ASSEMBLY
a.

Disconnect the No. 1 air conditioning radiator damper servo sub-assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A-6 (STE2) - B-3 (sigB) Always Below 1 Ω
A-5 (STE1) - B-2 (sigA) Always Below 1 Ω
A-8 (M-) - B-5 (M-) Always Below 1 Ω
A-7 (M+) - B-4 (M+) Always Below 1 Ω
A-4 (GND) - B-1 (GND) Always Below 1 Ω
A-6 (STE2) or B-3 (sigB) - Other terminals and Body ground Always 10 kΩ or higher
A-5 (STE1) or B-2 (sigA) - Other terminals and Body ground Always 10 kΩ or higher
A-8 (M-) or B-5 (M-) - Other terminals and Body ground Always 10 kΩ or higher
A-7 (M+) or B-4 (M+) - Other terminals and Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

9.PERFORM ACTIVE TEST USING GTS

NG

REPLACE AIR CONDITIONING HARNESS ASSEMBLY

9.PERFORM ACTIVE TEST USING GTS
a.

Connect the No. 1 air conditioning radiator damper servo sub-assembly connector.


b.

Remove the No. 2 air conditioning radiator damper servo sub-assembly.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING UNIT>DISASSEMBLY


c.

Connect the No. 1 blower damper servo sub-assembly connector to the No. 2 air conditioning radiator damper servo sub-assembly.


d.

Connect the GTS to the DLC3.


e.

Turn the power switch on (IG).


f.

Turn the GTS on.


g.

Enter the following menus: Body Electrical / Air Conditioner / Active Test.


h.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Air Inlet Damper Targ Pulse No. 1 blower damper servo sub-assembly pulse* Min.: 128
Max.: 383
Operates between 220 to 256 pulses

*: Though this Active Test is for the No. 1 blower damper servo sub-assembly, in this case it is used to check the operation of the No. 2 air conditioning radiator damper servo sub-assembly.


Body Electrical > Air Conditioner > Active Test
Tester Display
Air Inlet Damper Targ Pulse
50004 121 27
OK:

The No. 2 air conditioning radiator damper servo sub-assembly operates.



Result:
Proceed to
OK
NG



OK

REPLACE NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY

NG

REPLACE NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY