Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY) › 2017.09–2018.08
RM33C0E _51 Engine / Hybrid System _065433 HYBRID / BATTERY CONTROL _0331295 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P1A8000  Hybrid/EV Battery Stack 1 Delta SOC High  P1AD01B  Hybrid/EV Battery Block Circuit Resistance Above Threshold  


DESCRIPTION

The battery voltage sensor and the hybrid vehicle control ECU assembly calculate the SOC (state of charge) of the HV battery through the accumulated amperage in the HV battery. The battery voltage sensor sends the condition of the HV battery to the hybrid vehicle control ECU assembly. Then the hybrid vehicle control ECU assembly calculates the SOC based on the information and controls the charging and discharging of the HV battery based to the driving condition.

Based on the HV battery voltage and current, the battery voltage sensor calculates the resistance and judges if the HV battery has deteriorated.

A171602E06
4.333,0.813 4.729,0.813 false 3.521,0.802 3.854,0.458 false 4.24,1.969 4.469,1.969 false 2.656,0.813 2.24,0.813 false 3.51,1.958 3.813,2.292 false 4.781,0.719 6.531,0.885 1.75,0.167 10 false Example of Change in SOC 3.906,0.354 5.615,0.521 1.708,0.167 10 false Upper SOC Control Limit 3.875,2.198 5.573,2.365 1.698,0.167 10 false Lower SOC Control Limit 4.531,1.865 5.76,2.031 1.229,0.167 10 false Central SOC Level 1.281,0.698 2.281,0.917 1,0.219 10 false Control Region 2.813,1.896 3.188,2.063 0.375,0.167 10 false Time 2.063,1.198 2.406,1.365 0.344,0.167 10 false SOC

A408968E01
0.094,0.333 1.833,1.104 1.74,0.771 10 false Hybrid Battery 0.094,0.49 2.24,0.688 2.146,0.198 10 false Block 11 Voltage 0.083,0.854 1.813,1.531 1.729,0.677 10 false Hybrid Battery 0.094,1.021 2.24,1.219 2.146,0.198 10 false Block 10 Voltage 0.083,1.417 1.813,2.094 1.729,0.677 10 false Hybrid Battery 0.083,1.583 2.229,1.781 2.146,0.198 10 false Block 9 Voltage 0.083,2.135 1.813,2.813 1.729,0.677 10 false Hybrid Battery 0.094,2.302 2.24,2.5 2.146,0.198 10 false Block 8 Voltage 0.083,3 1.813,3.677 1.729,0.677 10 false Hybrid Battery 0.083,3.188 2.333,3.667 2.25,0.479 10 false Block 7 Voltage 0.104,3.927 1.833,4.604 1.729,0.677 10 false Hybrid Battery 0.094,4.104 2.344,4.583 2.25,0.479 10 false Block 6 Voltage 0.083,4.823 1.813,5.5 1.729,0.677 10 false Hybrid Battery 0.083,5.01 2.333,5.49 2.25,0.479 10 false Block 5 Voltage 0.104,5.719 1.833,6.396 1.729,0.677 10 false Hybrid Battery 0.104,6.75 2.354,7.229 2.25,0.479 10 false Block 3 Voltage 0.115,6.573 1.844,7.25 1.729,0.677 10 false Hybrid Battery 0.104,5.917 2.354,6.396 2.25,0.479 10 false Block 4 Voltage 0.104,7.198 1.833,7.875 1.729,0.677 10 false Hybrid Battery 0.104,7.385 2.354,7.865 2.25,0.479 10 false Block 2 Voltage 0.125,7.823 1.854,8.5 1.729,0.677 10 false Hybrid Battery 0.104,8.021 2.354,8.5 2.25,0.479 10 false Block 1 Voltage 1.771,8.302 4.021,8.781 2.25,0.479 10 false Voltage Detection Relay Circuit 3.448,8.573 5.865,8.854 2.417,0.281 10 false Battery Voltage Sensor 2.042,0.25 3.781,1.021 1.74,0.771 10 false VB17 2.031,0.76 3.771,1.531 1.74,0.771 10 false VB16 2.042,1.25 3.781,2.021 1.74,0.771 10 false VB15 2.052,1.75 3.792,2.521 1.74,0.771 10 false VB14 2.042,2.656 3.781,3.427 1.74,0.771 10 false VB12 2.031,3.563 3.771,4.333 1.74,0.771 10 false VB10 2.042,4.458 3.781,5.229 1.74,0.771 10 false VB8 2.063,5.333 3.802,6.104 1.74,0.771 10 false VB6 2.052,6.229 3.792,7 1.74,0.771 10 false VB4 2.042,7.125 3.781,7.896 1.74,0.771 10 false VB2 2.052,7.625 3.792,8.396 1.74,0.771 10 false VB1 2.052,8.115 3.885,8.563 1.833,0.448 10 false GB0 2.698,0.479 4.438,1.25 1.74,0.771 10 false Connected to circuit A 2.688,1.49 4.427,2.26 1.74,0.771 10 false Connected to circuit B 2.667,7.854 4.479,8.25 1.813,0.396 10 false Connected to circuit A 2.667,7.354 4.479,7.75 1.813,0.396 10 false Connected to circuit B 2.667,6.667 4.479,7.063 1.813,0.396 10 false Connected to circuit C 2.688,5.781 4.5,6.177 1.813,0.396 10 false Connected to circuit C 2.688,4.906 4.5,5.302 1.813,0.396 10 false Connected to circuit C 2.667,4 4.479,4.396 1.813,0.396 10 false Connected to circuit C 2.677,3.094 4.49,3.49 1.813,0.396 10 false Connected to circuit C 2.688,2.198 4.5,2.594 1.813,0.396 10 false Connected to circuit C 2.667,0.979 4.406,1.75 1.74,0.771 10 false Connected to circuit A 4.219,3.458 6.031,3.854 1.813,0.396 10 false Circuit A 4.219,4.021 6.031,4.417 1.813,0.396 10 false Circuit B 4.24,4.865 6.052,5.26 1.813,0.396 10 false Circuit C 5.927,5.438 7.073,5.917 1.146,0.479 10 false Converter Circuit 5.938,5.271 7.083,5.75 1.146,0.479 10 false Analogue/Digital

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P1A8000 Hybrid/EV Battery Stack 1 Delta SOC High Difference in capacity between each battery block is larger than standard.
(2 trip detection logic)
·

HV battery

·

Hybrid battery terminal block


Comes on Master Warning Light:
Comes on
P1AD01B Hybrid/EV Battery Block Circuit Resistance Above Threshold Resistance of an HV battery block exceeds the specified value.
(1 trip detection logic)
·

HV battery

·

Hybrid battery terminal block


Comes on Master Warning Light:
Comes on

Related Data List
DTC No. Data List
P1A8000
·

Internal Resistance 1 to 11

·

Hybrid Battery Block 1 to 11 Voltage *1

·

Hybrid Battery SOC


P1AD01B

HINT:
·

*1: Under normal conditions, the values of Hybrid Battery Block 1, 2, 9, 10 and 11 Voltage will be approximately 16 V and Hybrid Battery Block 3, 4, 5, 6, 7 and 8 Voltage will be approximately 32 V.

·

If there is a short or open in a battery block voltage detection line, the value of Hybrid Battery Block Voltage for the corresponding battery block will be lower than 8 V.



The following items can be helpful when performing repairs:

Data List
·

Ready Signal

·

Vehicle Speed

·

Accelerator Position

·

Shift Position

·

Engine Speed

·

Hybrid Battery Voltage

·

Hybrid Battery Current

·

BATT Voltage

·

Hybrid Battery SOC of Immediately after IG ON

·

Hybrid Battery Maximum SOC

·

Hybrid Battery Minimum SOC

·

Total Distance Traveled

·

Distance from DTC Cleared

·

Engine Run Time


Vehicle Control History Data

Hybrid Battery Voltage Low


HINT:
·

This DTC can be stored after clearing DTCs and driving the vehicle for approximately 10 minutes. (As 2 trip detection logic is also used, check for DTCs including pending DTCs.)

·

When the internal resistance of the HV battery increases, battery block voltage may drop.

·

If resistance is abnormal, the voltage of the battery blocks indicated by the DTCs are likely to decrease more than others during acceleration (discharging), and increase more during deceleration (charging).

·

In order to ensure HV battery performance, appropriate cooling performance must be maintained. Perform the following items as necessary. If cooling performance has decreased and "Maintenance Required for Traction Battery Cooling Parts See Owner's Manual" is displayed on the multi-information display, make sure to perform the following items:

-

Make sure the air intake port is not blocked.

-

Make sure there are no gaps between the connecting parts of the ducts.

-

Clean the No. 1 HV battery intake filter.

Clear the DTCs to reset the learning values even if no DTCs are stored.





CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY)>UTILITY


1.

Connect the GTS to the DLC3.

2.

Turn the power switch on (IG) and turn the GTS on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4.

Turn the power switch off and wait for 2 minutes or more.

5.

Turn the power switch on (IG) and turn the GTS on.

6.

Drive the vehicle on urban roads at a speed of 40 km/h (25 mph) or more for a total of at least 10 minutes. (It is not necessary to maintain the vehicle speed at 40 km/h (25 mph) throughout the road test.)

HINT:

This DTC may not be stored if the vehicle is stopped or being driven at a steady speed.


7.

Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.

8.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.




CAUTION / NOTICE / HINT

CAUTION:
·
A340358

Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the inverter with converter assembly

-

Disconnecting the low voltage connector of the HV battery


·
A357588

To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

·
A358042

After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·
A357589C02
1.573,0.74 2.021,0.427 true 2.094,0.344 2.354,0.51 0.26,0.167 10 false *a
*a Without waiting for 10 minutes


After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY)>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.


·

Make sure to insulate the high-voltage connectors and terminals of the HV battery with insulating tape after removing it.

If the HV battery stored without insulating the connectors and terminals, electric shock or fire may result.

·
A358021C02
0.531,4.146 0.844,4.344 0.313,0.198 10 false *a 2.74,4.146 3.052,4.344 0.313,0.198 10 false *b
*a Dealer
*b Battery Collection Agent


When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.

-

Accidents such as electric shock may result if the HV battery is disposed of improperly or abandoned. Therefore, make sure to return all HV batteries through an authorized collection agent.


·
A358020

After removing the HV battery, keep it away from water. Exposure to water may cause the HV battery to produce heat, resulting in a fire.



NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


PROCEDURE

1.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.


d.

Check and record any HV system DTCs and freeze frame data.

Powertrain > Hybrid Control > Trouble Codes
50001 397
Result:
Result Proceed to
"P0AFC00, P0AFC96, P308A12 or P0AFC62" is not output. A
"P0AFC00, P0AFC96, P308A12 or P0AFC62" is also output. B



e.

Turn the power switch off.



A

2.CHECK TOTAL DISTANCE DRIVEN

B

2.CHECK TOTAL DISTANCE DRIVEN
a.

Read the odometer to check the total distance the vehicle has been driven.

Result:
Result Proceed to
Total distance driven is less than 200000 km (124280 mile) A
Total distance driven is 200000 km (124280 mile) or more Current total distance driven - total distance driven when hybrid battery terminal block replaced = less than 200000 km (124280 mile) *1
Other than above B


HINT:

*1: If the hybrid battery terminal block has been replaced, use the total distance driven since it was replaced.




A

B

3.REPLACE HV BATTERY
3.REPLACE HV BATTERY

NEXT

REPLACE HYBRID BATTERY TERMINAL BLOCK