Refer to the description for DTC P1AC000.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P301100 | Hybrid/EV Battery Block 1 Circuit Resistance Out of Range (Extreme) | An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is extremely higher than the specified value.
(1 trip detection logic) |
·
HV battery ·
Hybrid battery terminal block ·
Battery voltage sensor |
Comes on | Master Warning Light:
Comes on |
| P30111E | Hybrid/EV Battery Block 1 Circuit Resistance Out of Range | An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is higher than the specified value.
(1 trip detection logic) |
·
HV battery ·
Hybrid battery terminal block ·
Battery voltage sensor |
Comes on | Master Warning Light:
Comes on |
| P301200 | Hybrid/EV Battery Block 2 Circuit Resistance Out of Range (Extreme) | An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is extremely higher than the specified value.
(1 trip detection logic) |
·
HV battery ·
Hybrid battery terminal block ·
Battery voltage sensor |
Comes on | Master Warning Light:
Comes on |
| P30121E | Hybrid/EV Battery Block 2 Circuit Resistance Out of Range | An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is higher than the specified value.
(1 trip detection logic) |
·
HV battery ·
Hybrid battery terminal block ·
Battery voltage sensor |
Comes on | Master Warning Light:
Comes on |
| P301300 | Hybrid/EV Battery Block 3 Circuit Resistance Out of Range (Extreme) | An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is extremely higher than the specified value.
(1 trip detection logic) |
·
HV battery ·
Hybrid battery terminal block ·
Battery voltage sensor |
Comes on | Master Warning Light:
Comes on |
| P30131E | Hybrid/EV Battery Block 3 Circuit Resistance Out of Range | An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is higher than the specified value.
(1 trip detection logic) |
·
HV battery ·
Hybrid battery terminal block ·
Battery voltage sensor |
Comes on | Master Warning Light:
Comes on |
| P301400 | Hybrid/EV Battery Block 4 Circuit Resistance Out of Range (Extreme) | An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is extremely higher than the specified value.
(1 trip detection logic) |
·
HV battery ·
Hybrid battery terminal block ·
Battery voltage sensor |
Comes on | Master Warning Light:
Comes on |
| P30141E | Hybrid/EV Battery Block 4 Circuit Resistance Out of Range | An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is higher than the specified value.
(1 trip detection logic) |
·
HV battery ·
Hybrid battery terminal block ·
Battery voltage sensor |
Comes on | Master Warning Light:
Comes on |
| P301500 | Hybrid/EV Battery Block 5 Circuit Resistance Out of Range (Extreme) | An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is extremely higher than the specified value.
(1 trip detection logic) |
·
HV battery ·
Hybrid battery terminal block ·
Battery voltage sensor |
Comes on | Master Warning Light:
Comes on |
| P30151E | Hybrid/EV Battery Block 5 Circuit Resistance Out of Range | An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is higher than the specified value.
(1 trip detection logic) |
·
HV battery ·
Hybrid battery terminal block ·
Battery voltage sensor |
Comes on | Master Warning Light:
Comes on |
| P301600 | Hybrid/EV Battery Block 6 Circuit Resistance Out of Range (Extreme) | An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is extremely higher than the specified value.
(1 trip detection logic) |
·
HV battery ·
Hybrid battery terminal block ·
Battery voltage sensor |
Comes on | Master Warning Light:
Comes on |
| P30161E | Hybrid/EV Battery Block 6 Circuit Resistance Out of Range | An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is higher than the specified value.
(1 trip detection logic) |
·
HV battery ·
Hybrid battery terminal block ·
Battery voltage sensor |
Comes on | Master Warning Light:
Comes on |
| P301700 | Hybrid/EV Battery Block 7 Circuit Resistance Out of Range (Extreme) | An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is extremely higher than the specified value.
(1 trip detection logic) |
·
HV battery ·
Hybrid battery terminal block ·
Battery voltage sensor |
Comes on | Master Warning Light:
Comes on |
| P30171E | Hybrid/EV Battery Block 7 Circuit Resistance Out of Range | An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is higher than the specified value.
(1 trip detection logic) |
·
HV battery ·
Hybrid battery terminal block ·
Battery voltage sensor |
Comes on | Master Warning Light:
Comes on |
| P301800 | Hybrid/EV Battery Block 8 Circuit Resistance Out of Range (Extreme) | An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is extremely higher than the specified value.
(1 trip detection logic) |
·
HV battery ·
Hybrid battery terminal block ·
Battery voltage sensor |
Comes on | Master Warning Light:
Comes on |
| P30181E | Hybrid/EV Battery Block 8 Circuit Resistance Out of Range | An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is higher than the specified value.
(1 trip detection logic) |
·
HV battery ·
Hybrid battery terminal block ·
Battery voltage sensor |
Comes on | Master Warning Light:
Comes on |
| P301900 | Hybrid/EV Battery Block 9 Circuit Resistance Out of Range (Extreme) | An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is extremely higher than the specified value.
(1 trip detection logic) |
·
HV battery ·
Hybrid battery terminal block ·
Battery voltage sensor |
Comes on | Master Warning Light:
Comes on |
| P30191E | Hybrid/EV Battery Block 9 Circuit Resistance Out of Range | An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is higher than the specified value.
(1 trip detection logic) |
·
HV battery ·
Hybrid battery terminal block ·
Battery voltage sensor |
Comes on | Master Warning Light:
Comes on |
| P302000 | Hybrid/EV Battery Block 10 Circuit Resistance Out of Range (Extreme) | An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is extremely higher than the specified value.
(1 trip detection logic) |
·
HV battery ·
Hybrid battery terminal block ·
Battery voltage sensor |
Comes on | Master Warning Light:
Comes on |
| P30201E | Hybrid/EV Battery Block 10 Circuit Resistance Out of Range | An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is higher than the specified value.
(1 trip detection logic) |
·
HV battery ·
Hybrid battery terminal block ·
Battery voltage sensor |
Comes on | Master Warning Light:
Comes on |
| P302100 | Hybrid/EV Battery Block 11 Circuit Resistance Out of Range (Extreme) | An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is extremely higher than the specified value.
(1 trip detection logic) |
·
HV battery ·
Hybrid battery terminal block ·
Battery voltage sensor |
Comes on | Master Warning Light:
Comes on |
| P30211E | Hybrid/EV Battery Block 11 Circuit Resistance Out of Range | An internal malfunction of the HV battery is detected. The difference in the internal resistance of each battery block is higher than the specified value.
(1 trip detection logic) |
·
HV battery ·
Hybrid battery terminal block ·
Battery voltage sensor |
Comes on | Master Warning Light:
Comes on |
These DTCs can be stored after clearing DTCs and driving the vehicle for approximately 10 minutes.
These DTCs are stored when a malfunction is detected in the HV battery or a battery voltage sensor. However, depending on the driving conditions, the malfunction may not be reproduced if the condition of the HV battery changes.
When the HV battery is malfunctioning:
- Voltage of 1 or more of the battery blocks has dropped.
- Voltage of all battery blocks is output randomly with no certain pattern.
When the battery voltage sensor is malfunctioning:
- While current is flowing to or from the HV battery, the voltage of a specific HV battery block will fluctuates.
In order to ensure HV battery performance, appropriate cooling performance must be maintained. Perform the following items as necessary. If cooling performance has decreased and "Maintenance Required for Traction Battery Cooling Parts See Owner's Manual" is displayed on the multi-information display, make sure to perform the following items:
Make sure the air intake port is not blocked.
Make sure there are no gaps between the connecting parts of the ducts.
Clean the No. 1 HV battery intake filter.
Clear the DTCs to reset the learning values even if no DTCs are stored.
| DTC No. | Data List |
|---|---|
| P301100 | ·
Hybrid Battery Block 1 to 11 Voltage*1 ·
Internal Resistance 1 to 11 |
| P30111E | |
| P301200 | |
| P30121E | |
| P301300 | |
| P30131E | |
| P301400 | |
| P30141E | |
| P301500 | |
| P30151E | |
| P301600 | |
| P30161E | |
| P301700 | |
| P30171E | |
| P301800 | |
| P30181E | |
| P301900 | |
| P30191E | |
| P302000 | |
| P30201E | |
| P302100 | |
| P30211E |
*1: Under normal conditions, the values of Hybrid Battery Block 1, 2, 9, 10 and 11 Voltage will be approximately 16 V and Hybrid Battery Block 3, 4, 5, 6, 7 and 8 Voltage will be approximately 32 V.
If there is a short or open in a battery block voltage detection line, the value of Hybrid Battery Block Voltage for the corresponding battery block will be lower than 8 V.
The Data List items Internal Resistance 1 to 11 indicate internal resistance correction values used by the hybrid vehicle control ECU assembly to detect malfunctions of the HV battery.
The following items can be helpful when performing repairs:
Ready Signal
Vehicle Speed
Accelerator Position
Shift Position
Engine Speed
Hybrid Battery Voltage
Hybrid Battery Current
BATT Voltage
Hybrid Battery SOC of Immediately after IG ON
Hybrid Battery Maximum SOC
Hybrid Battery Minimum SOC
Total Distance Traveled
Distance from DTC Cleared
Engine Run Time
Hybrid Battery Voltage Low
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Connect the GTS to the DLC3.
Turn the power switch on (IG) and turn the GTS on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the power switch off and wait for 2 minutes or more.
Turn the power switch on (IG) and turn the GTS on.
Drive the vehicle on urban roads for approximately 10 minutes.
This DTC may not be stored if the vehicle is stopped or being driven at a constant speed.
Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.
Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the HV battery
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
Make sure to insulate the high-voltage connectors and terminals of the HV battery with insulating tape after removing it.
If the HV battery stored without insulating the connectors and terminals, electric shock or fire may result.
| *a | Dealer |
| *b | Battery Collection Agent |
When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.
Accidents such as electric shock may result if the HV battery is disposed of improperly or abandoned. Therefore, make sure to return all HV batteries through an authorized collection agent.
After removing the HV battery, keep it away from water. Exposure to water may cause the HV battery to produce heat, resulting in a fire.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check for DTCs.
| Result | Proceed to |
|---|---|
| "P0AFC00, P0AFC96, P308A12 or P0AFC62" is not output. | A |
| "P0AFC00, P0AFC96, P308A12 or P0AFC62" is also output. | B |
Turn the power switch off.
A
B
| Result | Proceed to |
|---|---|
| On the HV battery blocks 3 to 8, one of the conditions in the table above is met. | A |
| Other than above | B |
A
B
Read the odometer to check the total distance the vehicle has been driven.
| Result | Proceed to | |
|---|---|---|
| Total distance driven is less than 200000 km (124280 mile) | A | |
| Total distance driven is 200000 km (124280 mile) or more | Current total distance driven - total distance driven when hybrid battery terminal block replaced = less than 200000 km (124280 mile) *1 | |
| Other than above | B | |
*1: If the hybrid battery terminal block has been replaced, use the total distance driven since it was replaced.
A
B
| Proceed to |
|---|
| NEXT |
NEXT
| Result | Proceed to |
|---|---|
| Either of the following conditions is met:
1. All conditions in table 1 are met. 2. All conditions in table 2 are met. |
A |
| Other than above | B |
A
B
| Result | Proceed to |
|---|---|
| All conditions in Table 1, Table 2 or Table 3 are met. | A |
| Other than above | B |
A
B
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check for DTCs.
| Result | Proceed to |
|---|---|
| P1CFD1E, P302100 or P30211E is not output. | A |
| P1CFD1E, P302100 or P30211E is also output. | B |
Turn the power switch off.
A
B
Read the odometer to check the total distance the vehicle has been driven.
| Result | Proceed to | |
|---|---|---|
| Total distance driven is less than 200000 km (124280 mile) | A | |
| Total distance driven is 200000 km (124280 mile) or more | Current total distance driven - total distance driven when hybrid battery terminal block replaced = less than 200000 km (124280 mile) *1 | |
| Other than above | B | |
*1: If the hybrid battery terminal block has been replaced, use the total distance driven since it was replaced.
A
B
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT