The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed and installed, or replaced during compressor with motor assembly removal/installation are shown below.
Orange wire harnesses and connectors indicate high-voltage circuits. To prevent electric shock, always follow the procedure described in the repair manual.
To prevent electric shock, wear insulated gloves when working on wire harnesses and components of the high voltage system.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
1.RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM
G3834
2.REMOVE SERVICE PLUG GRIP
3.CHECK TERMINAL VOLTAGE
Disconnect the engine room main wire.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>FRAME WIRE>REMOVAL
Remove the connector cover assembly.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>INVERTER WITH CONVERTER>REMOVAL
Check the terminal voltage.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>INVERTER WITH CONVERTER>REMOVAL
Install the connector cover assembly.
Connect the engine room main wire.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>FRAME WIRE>INSTALLATION
53295E
4.REMOVE COOL AIR INTAKE DUCT SEAL
17750A
5.REMOVE INLET AIR CLEANER ASSEMBLY
88704
6.DISCONNECT SUCTION HOSE SUB-ASSEMBLY
Remove the bolt and disconnect the suction hose sub-assembly from the compressor with motor assembly.
Remove the O-ring from the suction hose sub-assembly.
Seal the openings of the disconnected parts using vinyl tape to prevent moisture and foreign matter from entering them.
88711
7.DISCONNECT NO. 1 COOLER REFRIGERANT DISCHARGE HOSE SUB-ASSEMBLY
Remove the bolt and disconnect the No. 1 cooler refrigerant discharge hose sub-assembly from the compressor with motor assembly.
Remove the O-ring from the No. 1 cooler refrigerant discharge hose sub-assembly.
Seal the openings of the disconnected parts using vinyl tape to prevent moisture and foreign matter from entering them.
88370
8.REMOVE COMPRESSOR WITH MOTOR ASSEMBLY
Disconnect the 2 connectors.
| *a | Connector (A) |
| *b | Connector (B) |
| *c | Green-colored Lock |
|
Slide |
Using a screwdriver, slide the green-colored lock of the connector (A) as shown in the illustration to release it and disconnect the connector.
Make sure to wear insulated gloves.
Insulate the disconnected terminals and connector with insulating tape.
Disconnect the connector (B).
|
Bolt |
|
Nut |
Remove the bolt and 2 nuts.
Using an E8 "TORX" socket wrench, remove the 2 stud bolts and compressor with motor assembly.