If the power switch is on (IG), the battery ECU assembly applies current to the MREL terminal to turn the IGCT relay on. This supplies power to the IGCT terminals.
Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the HV battery
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
Make sure to insulate the high-voltage connectors and terminals of the HV battery with insulating tape after removing it.
If the HV battery stored without insulating the connectors and terminals, electric shock or fire may result.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
Be sure to wear insulated gloves and protective goggles.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 HV battery hose.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY ECU (for LITHIUM-ION BATTERY)>REMOVAL
Disconnect the z16 battery ECU assembly connector.
Before disconnecting the connector, check that it is not loose or disconnected.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
| *a | Front view of wire harness connector
(to Battery ECU Assembly) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z16-13 (IGCT) - Body ground | Power switch on (IG) | 11 to 14 V |
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
If the power switch is turned on (IG) with the connectors disconnected, other DTCs will be stored. Be sure to clear the DTCs after the inspection.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the z16 battery ECU assembly connector.
Install the No. 1 HV battery hose.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves and protective goggles.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 HV battery hose.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY ECU (for LITHIUM-ION BATTERY)>REMOVAL
Disconnect the z16 battery ECU assembly connector.
Before disconnecting the connector, check that it is not loose or disconnected.
| *a | Front view of wire harness connector
(to Battery ECU Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z16-27 (GND) - Body ground | Always | Below 1 Ω |
| z16-3 (GND1) - Body ground | Always | Below 1 Ω |
| z16-4 (ERTH) - Body ground | Always | Below 1 Ω |
Reconnect the z16 battery ECU assembly connector.
Install the No. 1 HV battery hose.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | No. 4 Relay Block |
| *2 | IGCT NO. 2 Fuse |
Remove the IGCT NO. 2 fuse from the No. 4 relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| IGCT NO. 2 fuse terminals - Body ground | Always | Below 1 Ω |
Install the IGCT NO. 2 fuse.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves and protective goggles.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 HV battery hose.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY ECU (for LITHIUM-ION BATTERY)>REMOVAL
Disconnect the z16 battery ECU assembly connector.
Before disconnecting the connector, check that it is not loose or disconnected.
Remove the IGCT NO. 2 fuse from the No. 4 relay block.
Measure the resistance according to the value(s) in the table below.
| *1 | No. 4 Relay Block | *a | IGCT NO. 2 Fuse Holder |
| *b | Front view of wire harness connector
(to Battery ECU Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z16-13 (IGCT) - 2 (IGCT NO. 2 fuse holder) | Always | Below 1 Ω |
Install the IGCT NO. 2 fuse.
Reconnect the z16 battery ECU assembly connector.
Install the No. 1 HV battery hose.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the IGCT NO. 2 fuse from the No. 4 relay block.
Remove the IGCT relay from the No. 6 relay block.
Measure the resistance according to the value(s) in the table below.
| *A | LHD | *B | RHD |
| *1 | No. 4 Relay Block | *2 | IGCT NO. 2 Fuse Holder |
| *3 | No. 6 Relay Block | *4 | IGCT Relay Holder |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 5 (IGCT relay holder 5) - 1 (IGCT NO. 2 fuse holder 1) | Always | Below 1 Ω |
Install the IGCT relay.
Install the IGCT NO. 2 fuse.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves and protective goggles.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 HV battery hose.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY ECU (for LITHIUM-ION BATTERY)>REMOVAL
Disconnect the z16 battery ECU assembly connector.
Before disconnecting the connector, check that it is not loose or disconnected.
Remove the IGCT NO. 2 fuse from the No. 4 relay block.
Measure the resistance according to the value(s) in the table below.
| *1 | No. 4 Relay Block | *a | IGCT NO. 2 Fuse Holder |
| *b | Front view of wire harness connector
(to Battery ECU Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z16-13 (IGCT) or 2 (IGCT-NO. 2 fuse holder) - Body ground and other terminals | Always | 10 kΩ or higher |
Install the IGCT NO. 2 fuse.
Reconnect the z16 battery ECU assembly connector.
Install the No. 1 HV battery hose.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| Proceed to |
|---|
| NEXT |
NEXT