The two sensing chambers of the differential pressure sensor assembly are mounted to monitor the pressure before and after the DPF* catalytic converter. The sensor itself is not located on the engine assembly in order to reduce the influence of vibration. The sensor is a semiconductor-type that is not influenced by exhaust gases.
The ECM compares the exhaust gas pressure before and after the DPF catalytic converter by monitoring the pressure using the upstream and downstream sensing chambers of the differential pressure sensor assembly. If the difference between the pressure before and after the catalytic converter exceeds a predetermined level, the ECM judges that the catalytic converter has clogged with particulate matter (PM). When the ECM judges that a partially clogged condition exists, the ECM begins to perform DPF catalyst regeneration.
When the output voltage of the sensor deviates from the normal operating range, the ECM interprets this as a malfunction of the sensor circuit, and DTC P1425, P1427, or P1428 will be stored and the MIL will be illuminated.
*: Diesel Particulate Filter.
If the vacuum hoses of the differential pressure sensor assembly are incorrectly connected (crossed), the ECM interprets this as abnormal pressure difference, and DTC P1426 (Differential Pressure Sensor [Installation]) will be stored and the MIL will be illuminated.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P1425 | Differential pressure sensor output voltage is less than 0.4 V, or more than 4.8 V for 1 second or more
(1 trip detection logic) |
·
Open or short in differential pressure sensor assembly circuit ·
Incorrect differential pressure sensor assembly hose routing ·
Differential pressure sensor assembly ·
ECM |
| P1427 | Differential pressure sensor output voltage is less than 0.4 V for 1 second or more
(1 trip detection logic) |
·
Open or short in differential pressure sensor assembly circuit ·
Incorrect differential pressure sensor assembly hose routing ·
Differential pressure sensor assembly ·
ECM |
| P1428 | Differential pressure sensor output voltage is more than 4.8 V for 1 second or more
(1 trip detection logic) |
·
Open or short in differential pressure sensor assembly circuit ·
Incorrect differential pressure sensor assembly hose routing ·
Differential pressure sensor assembly ·
ECM |
After confirming DTC P1425, P1427 and P1428, check the differential pressure by entering the following menus on the intelligent tester: Powertrain / Engine and ECT / Data List / DPF Differential Pressure.
| Condition | Differential Pressure Output | Sensor Condition |
|---|---|---|
| Ignition Switch ON | Approximately 0 kPa | Normal |
| Always | -5 or 100 kPa | Open or short circuit |
| 3000 rpm (No engine load) | Negative output | Incorrect arrangement of hose piping |
After replacing the ECM, the new ECM needs registration (Click here Engine / Hybrid System>N04C-UH (ENGINE CONTROL)>ECD SYSTEM>REGISTRATION) and initialization (Click here Engine / Hybrid System>N04C-UH (ENGINE CONTROL)>ECD SYSTEM>INITIALIZATION).
Read freeze frame data using the intelligent tester. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, and other data from the time the malfunction occurred.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the tester on.
Enter the following menus: Powertrain / Engine and ECT / Data List / DPF Differential Pressure.
Check that differential pressure is within the specification below.
| Condition | Differential Pressure | Proceed to |
|---|---|---|
| Always | -5 kPa or less | A |
| -1 to 1 kPa | B | |
| 100 kPa | C |
A
B
Click hereEngine / Hybrid System>N04C-UH (ENGINE CONTROL)>ECD SYSTEM>CHECK FOR INTERMITTENT PROBLEMS
C
Check if the vacuum hose routing between the differential pressure sensor assembly and the catalytic converter is correct.
Check that there is no exhaust gas leak between the differential pressure sensor assembly and the catalytic converter.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be careful of being burned by exhaust gases during the following inspection.
Disconnect the vacuum hose (both upstream and downstream) on the differential pressure sensor assembly.
Start the engine.
Check if there are exhaust gas pulsations from both vacuum hoses during idling.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the differential pressure sensor assembly connector.
Disconnect the ECM connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B60-27 (PEX) - A43-2 (PEX) | Always | Below 1 Ω |
| B59-18 (VC) - A43-3 (VC) | Always | Below 1 Ω |
| B59-28 (E2) - A43-1 (E2) | Always | Below 1 Ω |
| B60-27 (PEX) or A43-2 (PEX) - Body ground | Always | 10 kΩ or higher |
| B59-18 (VC) or A43-3 (VC) - Body ground | Always | 10 kΩ or higher |
Reconnect the differential pressure sensor assembly connector.
Reconnect the ECM connectors.
| Proceed to |
|---|
| OK |
| NG |
OK
NG