The exhaust brake with bracket solenoid assembly, opens and closes according to the signals from the ECM. The ECM receives the signals from the exhaust retarder switch assembly. Through the exhaust brake with bracket solenoid assembly, the ECM controls the negative pressure applied to the exhaust retarder assembly.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P1674 | Open or short in exhaust brake solenoid circuit for more than 3 seconds with clutch pedal released
(1 trip detection logic) |
·
Open or short in exhaust brake solenoid circuit ·
Exhaust brake with bracket solenoid assembly ·
ECM |
After replacing the ECM, the new ECM needs registration (Click hereEngine / Hybrid System>N04C-VQ (ENGINE CONTROL)>ECD SYSTEM>REGISTRATION) and initialization (Click hereEngine / Hybrid System>N04C-VQ (ENGINE CONTROL)>ECD SYSTEM>INITIALIZATION).
Read freeze frame data using the GTS. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was moving or stationary, whether the engine was warmed up or not, as well as other data recorded at the time of a malfunction.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B102-3 (EXB) - B102-1 (E1) | Exhaust brake is operating | 11 to 14 V |
| *a | Component with harness connected
(ECM) |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the exhaust brake with bracket solenoid assembly.
Check operation of the exhaust brake with bracket solenoid assembly.
| Port Connection | Condition | Specified Condition |
|---|---|---|
| A - B | Battery voltage is not applied | Air does not flow |
| B - Air filter | Air flows | |
| A - B | Battery voltage is applied to terminals 1 and 2 | Air flows |
| B - Air filter | Air does not flow |
| *1 | Exhaust Brake with Bracket Solenoid Assembly |
| *2 | Air Filter |
| *a | Component without harness connected
(Exhaust Brake Solenoid) |
| *b | Port A |
| *c | Port B |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the exhaust brake with bracket solenoid assembly connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A4-1 - B102-3 (EXB) | Always | Below 1 Ω |
| A4-2 - Body ground | Always | Below 1 Ω |
| A4-1 or B102-3 (EXB) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG