The mass air flow meter sub-assembly measures the amount of air flowing through the throttle valve. The ECM uses this information to determine the fuel injection time and provide a proper air-fuel ratio. Inside the mass air flow meter sub-assembly, there is a heated platinum wire exposed to the flow of intake air.
By applying a specific current to the wire, the ECM heats this wire to a given temperature. The flow of incoming air cools the wire and an internal thermistor, affecting their resistance. To maintain a constant current value, the ECM varies the voltage applied to these components* in the mass air flow meter sub-assembly. The voltage level is proportional to the air flow through the sensor. The ECM interprets this voltage as the intake air amount.
*: The circuit is constructed so that the platinum hot wire and temperature sensor provide a bridge circuit, with the power transistor controlled so that the potential of A and B remains equal to maintain the set temperature.
When any of these DTCs are set, the ECM enters fail-safe mode. During fail-safe mode, the ignition timing is calculated by the ECM, according to the engine rpm and throttle valve position. Fail-safe mode continues until a pass condition is detected.
| DTC No. | DTC Detection Condition | Suspected Area |
|---|---|---|
| P0100 | When mass air flow meter sub-assembly circuit is open or shorted for more than 3 seconds
(1 trip detection logic) |
·
Open or short in mass air flow meter sub-assembly circuit ·
Mass air flow meter sub-assembly ·
ECM |
| P0102 | When mass air flow meter sub-assembly circuit is open for more than 3 seconds
(1 trip detection logic) |
·
Open in mass air flow meter sub-assembly circuit ·
Mass air flow meter sub-assembly ·
Short in ground circuit ·
ECM |
| P0103 | When mass air flow meter sub-assembly circuit is shorted for more than 3 seconds
(1 trip detection logic) |
·
Short in mass air flow meter sub-assembly circuit (+B circuit) ·
Mass air flow meter sub-assembly ·
ECM |
If there is a defect in the mass air flow meter sub-assembly or an open or short circuit, the voltage level will deviate outside the normal operating range. The ECM interprets this deviation as a defect in the mass air flow meter sub-assembly and sets a DTC.
Example:
When the sensor voltage output is less than 0.2 V or more than 4.9 V and if either condition continues more than 3 seconds.
This monitor runs for 3 seconds (the first 3 seconds of engine idle) after the engine is started (1 trip detection logic).
When DTC P0100, P0102 or P0103 is detected, check the air flow ratio by selecting the following menu items on the GTS: Powertrain / Engine and ECT / Data List / MAF.
| Air Flow Value (g/sec.) | Malfunction |
|---|---|
| Approximately 0 | ·
Open in mass air flow meter sub-assembly power source circuit ·
Open or short in VG circuit |
| 271.0 or more | Open in E2G circuit |
Read freeze frame data using the GTS. Freeze frame data records the engine conditions when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.
Connect the GTS to the DLC3.
Start the engine.
Turn the GTS ON.
Enter the following menus: Powertrain / Engine and ECT / Data List / MAF.
Read the values.
| Mass Air Flow Rate (g/sec.) | Proceed To |
|---|---|
| 0.0 | A |
| 271.0 or more | B |
| Between 0.0 and 271.0* | C |
*: The value must change when the throttle valve is opened or closed.
A
B
C
Disconnect the mass air flow meter sub-assembly connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| B51-1 (+B) - Body ground | Ignition switch ON | 11 to 14 V |
| *a | Front view of wire harness connector
(to Mass air flow meter sub-assembly) |
| Proceed To |
|---|
| OK |
| NG |
OK
NG
Start the engine.
Measure the voltage of the ECM connector.
The A/C switch should be turned OFF.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B75-28 (VG) - B75-30 (E2G) | Engine is idling | 0.5 to 3.0 V |
| *a | Component with harness connected
(ECM) |
| Proceed To |
|---|
| OK |
| NG |
OK
NG
Disconnect the mass air flow meter sub-assembly connector.
Disconnect the ECM connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B51-3 (VG) - B75-28 (VG) | Always | Below 1 Ω |
| B51-2 (E2G) - B75-30 (E2G) | Always | Below 1 Ω |
| B51-3 (VG) or B75-28 (VG) - Body ground | Always | 10 kΩ or higher |
| Proceed To |
|---|
| OK |
| NG |
OK
NG
Disconnect the mass air flow meter sub-assembly connector.
Remove the NO. 2 integration relay from the NO. 2 relay block and junction block assembly.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B51-1 (+B) - 2D-4 | Always | Below 1 Ω |
| B51-1 (+B) or 2D-4 - Body ground | Always | 10 kΩ or higher |
| Proceed To |
|---|
| OK |
| NG |
OK
NG
Disconnect the mass air flow meter sub-assembly connector.
Measure the resistance of the ECM connector.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B51-2 (E2G) - Body ground | Always | Below 1 Ω |
| Proceed To |
|---|
| OK |
| NG |
OK
NG
Disconnect the mass air flow meter sub-assembly connector.
Disconnect the ECM connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B51-3 (VG) - B75-28 (VG) | Always | Below 1 Ω |
| B51-2 (E2G) - B75-30 (E2G) | Always | Below 1 Ω |
| B51-3 (VG) or B75-28 (VG) - Body ground | Always | 10 kΩ or higher |
| Proceed To |
|---|
| OK |
| NG |
OK
NG