Home › Engine / Hybrid System › 2TR-FE (CHARGING) › GENERATOR (for 100A Type)
RM2850E _51 Engine / Hybrid System _073308 2TR-FE CHARGING _0357067 GENERATOR(for 100A Type) A

2TR-FE CHARGING  GENERATOR(for 100A Type)  REMOVAL  


PROCEDURE

Hide 1. PRECAUTION

NOTICE:

After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work (Click here General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


Hide 2.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here General>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION).


Hide 51405A 3.REMOVE NO. 1 ENGINE UNDER COVER

Hide 58410 4.REMOVE ENGINE SERVICE HOLE COVER

Hide 58734B 5.REMOVE REAR ENGINE SERVICE COVER WEATHERSTRIP

Hide 58521D 6.REMOVE ENGINE SERVICE HOLE COVER MAT

Hide 58420 7.REMOVE NO. 2 ENGINE SERVICE HOLE COVER ASSEMBLY

Hide 58123A 8.REMOVE SHIFT AND SELECT LEVER SUPPORT WITH BOOTS

Hide 33506F 9.REMOVE FLOOR SHIFT CONTROL SHIFT LEVER RETAINER SUB-ASSEMBLY

Hide 58701A 10.REMOVE FRONT ENGINE SERVICE COVER PANEL SUB-ASSEMBLY

Hide 88310A 11.REMOVE NO. 1 V (COOLER COMPRESSOR TO CRANKSHAFT PULLEY) BELT

Hide 16361A 12.REMOVE FAN AND GENERATOR V BELT

Hide 27020 13.REMOVE GENERATOR ASSEMBLY

a.
A399899

Remove the terminal cap.


b.
A399900E01
0.76,0.417 1,0.604 0.24,0.188 10 true *b 0.469,0.99 0.667,1.208 0.198,0.219 10 true *a 2.406,1.427 2.604,1.646 0.198,0.219 10 true *c

Remove the nut and disconnect the terminal B.


c.

Disconnect the connector and detach the clamp.

Text in Illustration
*a Nut
*b Connector
*c Clamp


d.
A399902

Remove the 3 bolts and generator assembly.


e.

Remove the bolt and wiring harness bracket from the generator assembly.