Home › Engine / Hybrid System › N04C-UH (CHARGING) › GENERATOR
RM2850E _51 Engine / Hybrid System _073313 N04C-UH CHARGING _0357078 GENERATOR A

N04C-UH CHARGING  GENERATOR  REMOVAL  


PROCEDURE

Hide 1.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

Hide 16701 2.REMOVE FAN SHROUD SUB-ASSEMBLY

Hide 16206C 3.SEPARATE WATER BY-PASS PIPE SUB-ASSEMBLY

Hide 27020 5.REMOVE GENERATOR ASSEMBLY

a.
A342116

Disconnect the 4 wire harness clamps.


b.

Remove the 2 bolts and disconnect the 2 wire harnesses from the generator bracket.


c.
A157248

Remove the terminal cap and the nut, and then disconnect the wire harness from the terminal B.


d.

Disconnect the connector from the generator assembly.


e.
A149666

Remove the 3 bolts and the generator bracket.


f.

Remove the bolt and the generator assembly.