SG400
1.INSTALL UREA SENSOR ASSEMBLY
77871A
2.INSTALL UREA PUMP
77801A
3.INSTALL UREA TANK SUB-ASSEMBLY
Perform "Inspection After Repairs" after replacing the urea tank sub-assembly.
Install the bracket to the bolt.
| *a | Hook (Vehicle Side) |
Connect the 2 hooks and install the urea tank sub-assembly to the body with the 5 bolts.
77840A
4.CONNECT UREA TUBE WITH HEATER ASSEMBLY
Check for dirt or mud on the urea pump and around the urea tube connector before connection. Clean if necessary.
Install the urea tube with heater assembly to the urea pump.
If there is any solidified urea solution (white solids) on the connection areas of the urea tube with heater assembly and urea pump, clean the solids off with water. Otherwise, they may prevent the O-ring from sealing properly.
Wash the connection area of the urea tube connector with water to remove all solidified urea solution (white solids).
Wipe off the connection area of the urea pump with water to remove all solidified urea solution (white solids).
|
Push |
|
Push Down |
Align the axis of the urea tube connector with the axis of the urea pump. Push the urea tube connector into the urea pump until the urea tube connector makes a "click" sound.
After connecting the urea pump and the urea tube connector, check that the urea pump and urea tube connector are securely connected by trying to pull them apart.
Attach the lock claws to the urea tube connector by pushing down on the cover.
Attach the 3 clamps.
5.CONNECT WIRE HARNESS
Attach the 6 clamps and connect the wire harness.
Connect the connector.
|
Push In |
Connect the connector to the combination gauge assembly and push in the connector lock.
Connect the connector to the urea pump and push the tub as shown in the illustration.
77851A
6.INSTALL UREA TANK PROTECTOR
Attach the 2 claws and install the urea tank protector with the clip.
7.ADD UREA SOLUTION (AdBlue)
77830A
8.INSTALL UREA TANK CAP ASSEMBLY