Home › Engine / Hybrid System › N04C-WA (EMISSION CONTROL) › UREA TANK › from 2019.08
RM2850E _51 Engine / Hybrid System _082614 N04C-WA EMISSION CONTROL _0403729 UREA TANK A

N04C-WA EMISSION CONTROL  UREA TANK  INSTALLATION  


PROCEDURE

Hide 77801A 3.INSTALL UREA TANK SUB-ASSEMBLY

HINT:

Perform "Inspection After Repairs" after replacing the urea tank sub-assembly.

Click hereEngine / Hybrid System>N04C-WA (EMISSION CONTROL)>UREA SELECTIVE CATALYTIC REDUCTION SYSTEM>INITIALIZATION


a.

Install the bracket to the bolt.


b.
A451097C01
2.552,0.896 2.552,0.74 2.552,0.74 2.76,0.74 false 0.844,0.563 0.844,0.406 0.844,0.406 0.719,0.406 false 0.521,0.323 0.708,0.521 0.188,0.198 10 false *a 2.802,0.656 2.99,0.844 0.188,0.188 10 true *a
*a Hook (Vehicle Side)


Connect the 2 hooks and install the urea tank sub-assembly to the body with the 5 bolts.

Torque:
14.3 N*m (146 kgf*cm, 11 ft.*lbf)


Hide 77840A 4.CONNECT UREA TUBE WITH HEATER ASSEMBLY

NOTICE:

Check for dirt or mud on the urea pump and around the urea tube connector before connection. Clean if necessary.


a.

Install the urea tube with heater assembly to the urea pump.

HINT:

If there is any solidified urea solution (white solids) on the connection areas of the urea tube with heater assembly and urea pump, clean the solids off with water. Otherwise, they may prevent the O-ring from sealing properly.


i.

Wash the connection area of the urea tube connector with water to remove all solidified urea solution (white solids).


ii.

Wipe off the connection area of the urea pump with water to remove all solidified urea solution (white solids).


iii.
A451144C01
0,0 0,0 false
V100135

Push
V100136

Push Down


Align the axis of the urea tube connector with the axis of the urea pump. Push the urea tube connector into the urea pump until the urea tube connector makes a "click" sound.


iv.

After connecting the urea pump and the urea tube connector, check that the urea pump and urea tube connector are securely connected by trying to pull them apart.


v.

Attach the lock claws to the urea tube connector by pushing down on the cover.



b.
A451096

Attach the 3 clamps.


Hide 5.CONNECT WIRE HARNESS

a.
A451093

Attach the 6 clamps and connect the wire harness.


b.

Connect the connector.


c.
A451145C01
0,0 0,0 false
V100135

Push In


Connect the connector to the combination gauge assembly and push in the connector lock.


d.
A451147

Connect the connector to the urea pump and push the tub as shown in the illustration.


Hide 77851A 6.INSTALL UREA TANK PROTECTOR

a.
A451090

Attach the 2 claws and install the urea tank protector with the clip.


Hide 7.ADD UREA SOLUTION (AdBlue)

Hide 77830A 8.INSTALL UREA TANK CAP ASSEMBLY