A thermistor, whose resistance value varies according to the Engine Coolant Temperature (ECT), is built into the ECT sensor. The structure of the sensor and its connection to the ECM are the same as those of the intake air temperature sensor.
When DTC P0115, P0117 or P0118 is stored, the ECM enters fail-safe mode. During fail-safe mode, the engine coolant temperature is estimated to be 80°C (176°F) by the ECM. Fail-safe mode continues until a pass condition is detected.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P0115 | Open or short in ECT sensor circuit for 0.5 seconds (1 trip detection logic) | ·
Open or short in ECT sensor circuit ·
ECT sensor ·
ECM |
| P0117 | Short in ECT sensor circuit for 0.5 seconds (1 trip detection logic) | ·
Short in ECT sensor circuit ·
ECT sensor ·
ECM |
| P0118 | Open in ECT sensor circuit for 0.5 seconds (1 trip detection logic) | ·
Open in ECT sensor circuit ·
ECT sensor ·
ECM |
When any of these DTCs are set, check the ECT by selecting the following menu items on the intelligent tester: Powertrain / Engine and ECT / Data List / Coolant Temp.
| Temperature Displayed | Malfunction |
|---|---|
| -40°C (-40°F) | Open circuit |
| 140°C (284°F) or higher | Short circuit |
Read freeze frame data using the intelligent tester. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.
Connect the intelligent tester to the DLC3.
Turn the engine switch on (IG) and turn the tester ON.
Enter the following menus: Powertrain / Engine and ECT / Data List / Coolant Temp.
Read the value displayed on the tester.
Between 80°C and 100°C (176°F and 212°F) with warm engine.
| Temperature Displayed | Proceed to |
|---|---|
| -40°C (-40°F) | A |
| 140°C (284°F) or higher | B |
| Between 80°C and 100°C (176°F and 212°F) | C |
If there is an open circuit, the intelligent tester indicates -40°C (-40°F).
If there is a short circuit, the intelligent tester indicates 140°C (284°F) or higher.
A
B
C
Disconnect the Engine Coolant Temperature (ECT) sensor connector.
Connect terminals THW and E2 of the ECT sensor connector on the wire harness side.
Connect an intelligent tester to the DLC3.
Turn the engine switch on (IG) and turn the tester ON.
Enter the following menus: Powertrain / Engine and ECT / Data List / Coolant Temp.
Read the value displayed on the tester.
140°C (284°F) or higher.
NG
OK
Disconnect the ECT sensor connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D7-2 (THW) - D2-97 (THW) | Always | Below 1 Ω |
| D7-1 (E2) - D2-96 (ETHW) |
OK
NG
Disconnect the ECT sensor connector.
Connect an intelligent tester to the DLC3.
Turn the engine switch on (IG) and turn the tester ON.
Enter the following menus: Powertrain / Engine and ECT / Data List / Coolant Temp.
Read the value displayed on the tester.
-40°C (-40°F)
NG
OK
Disconnect the ECT sensor connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D7-2 (THW) or D2-97 (THW) - Body ground | Always | 10 kΩ or higher |
OK
NG