Performing reset memory will clear the learned values of both the sensor (deceleration sensor zero point calibration) and CVT oil pressure (CVT oil pressure calibration). Make sure to perform reset memory, deceleration sensor zero point calibration and CVT oil pressure calibration when replacing any of the parts shown in the following table.
| Replaced Part |
|---|
·
Continuously variable transaxle assembly ·
ECM ·
Oil pressure sensor ·
Brake actuator assembly (Skid control ECU) (w/o VSC) ·
Yaw rate sensor (w/ VSC) ·
Deceleration sensor (w/o VSC) |
After performing reset memory, always perform yaw rate sensor (deceleration sensor zero point) calibration first, and then CVT oil pressure calibration.
Intelligent tester only:
RESET MEMORY/CALIBRATION
Perform reset memory as follows:
Turn the engine switch off.
Move the shift lever to P and apply the parking brake.
Connect the intelligent tester to the DLC3.
Turn the engine switch on (IG).
Do not start the engine.
Turn the intelligent tester on.
Enter the following menus: Powertrain / Engine and ECT / Utility / Reset Memory.
Keep the vehicle stopped, level and stable during the calibration.
Make sure that the shift lever is in P.
Make sure that the engine is stopped. To prevent idling vibrations, do not start the engine.
Make sure that the engine switch is on (IG).
Perform yaw rate sensor calibration (deceleration sensor zero point calibration) as follows:
Turn the engine switch on (IG) and wait at least 2 seconds.
Enter the following menus: Powertrain / Engine and ECT / Utility / Deceleration Sensor zero Point Calibration.
When "Complete" is displayed on the intelligent tester, the deceleration sensor zero point calibration is completed.
If "Error" is displayed on the intelligent tester, the deceleration sensor circuit may have a malfunction.
Shaking or vibrating the vehicle during zero point calibration may cancel the calibration. If "Error" is displayed on the intelligent tester, perform calibration again.
Perform CVT oil pressure calibration as follows:
Turn the engine switch off and wait at least 30 seconds.
Turn the engine switch on (IG) and wait at least 2 seconds.
Do not start the engine.
CVT oil pressure calibration is performed with the engine switch on (IG) (engine stopped). However, the calibration cannot be performed under the following conditions:
When the oil pressure sensor value is 0.065 MPa (0.663 kgf/cm2, 9.43 psi) or more
When the CVT oil temperature is -5°C (23°F) or less or 100°C (212°F) or more
Start the engine and wait at least 5 seconds.
Start the engine with the shift lever in P.
After starting the engine, do not operate the accelerator pedal.
Enter the following menus: Powertrain / Engine and ECT / Utility / CVT Oil Pressure Calibration.
During CVT oil pressure calibration, the engine idle speed will increase.
When "Complete" is displayed on the intelligent tester, the CVT oil pressure calibration is completed.
The learned values cannot be cleared by only disconnecting and reconnecting the cable to the negative (-) battery terminal.