Home › Drivetrain › K112 (CVT) › CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM › from 2014.09
RM24M0E _52 Drivetrain _059572 K112 CVT _0292047 CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM C

K112 CVT  CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM  P2763  Torque Converter Clutch Pressure Control Solenoid Control Circuit High (Shift Solenoid Valve DSU)  P2764  Torque Converter Clutch Pressure Control Solenoid Control Circuit Low (Shift Solenoid Valve DSU)  


DESCRIPTION

The ECM controls the signal to the shift solenoid valve DSU and performs lock-up clutch pressure control in response to the input torque value.

DTC No. DTC Detection Condition
1.

Diagnosis Condition

2.

Malfunction Status

3.

Malfunction Time

4.

Other


Trouble Area
P2763
1.

The vehicle is being driven.

2.

There is an open circuit in the shift solenoid valve DSU circuit.

3.

Detected 20 times or more consecutively

4.

1 trip detection logic


·

Open in shift solenoid valve DSU circuit

·

Continuously variable transaxle assembly

·

ECM


P2764
1.

The vehicle is being driven.

2.

There is a short circuit in the shift solenoid valve DSU circuit.

3.

Detected 20 times or more consecutively

4.

1 trip detection logic


·

Short in shift solenoid valve DSU circuit

·

Continuously variable transaxle assembly

·

ECM



MONITOR DESCRIPTION

These DTCs indicate an open or short circuit in the shift solenoid valve DSU circuit. The ECM controls lock-up by turning the shift solenoid valve DSU on/off. When there is an open or short circuit in the shift solenoid valve DSU circuit, the ECM detects the problem, illuminates the MIL and stores the DTCs.

WIRING DIAGRAM

C200619E38
5.813,2.927 6.125,3.125 0.313,0.198 10 false D2 5.813,3.104 6.198,3.302 0.385,0.198 10 false ECM 5.635,1.24 6.052,1.438 0.417,0.198 10 false DSU 5.344,1.365 5.542,1.563 0.198,0.198 10 false 80 3.219,1.125 3.583,1.323 0.365,0.198 10 false DSU 3.625,1.365 3.823,1.563 0.198,0.198 10 false 7 1.49,1.719 3.448,1.917 1.958,0.198 10 false Shift Solenoid Valve DSU 1.167,2.688 1.479,2.885 0.313,0.198 10 false D67 1.167,2.875 3.302,3.24 2.135,0.365 10 false Transmission Wire (Continuously Variable Transaxle Assembly)

PROCEDURE

1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE DSU)
a.
C199169E75
2.448,1.688 1.896,1.219 true 0.073,0.042 0.385,0.24 0.313,0.198 10 false *1 2.49,1.625 2.854,1.823 0.365,0.198 10 false DSU

Disconnect the transmission wire connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
7 (DSU) - Body ground 20°C (68°F) 11 to 15 Ω


Text in Illustration
*1 Component without harness connected
(Transmission Wire)



OK

2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)

NG

5.REPLACE CONTINUOUSLY VARIABLE TRANSAXLE ASSEMBLY
2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
a.

Disconnect the ECM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
D2-80 (DSU) - Body ground 20°C (68°F) 11 to 15 Ω




OK

3.REPLACE ECM

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.REPLACE ECM

NEXT

4.PERFORM INITIALIZATION
5.REPLACE CONTINUOUSLY VARIABLE TRANSAXLE ASSEMBLY

NEXT