Home › Drivetrain › K112 (CVT) › CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM › from 2014.09
RM24M0E _52 Drivetrain _059572 K112 CVT _0292047 CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM C

K112 CVT  CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM  P282B  Pressure Control Solenoid "K" Electrical (Shift Solenoid Valve SLS)  


DESCRIPTION

The ECM uses the shift solenoid valve SLS to control the secondary pulley pressure and belt clamping pressure according to the input shaft torque. Additionally, shift solenoid valve SLS is used to control the forward and reverse clutch hydraulic pressure when the forward and reverse clutch is engaged.

DTC No. DTC Detection Condition
1.

Diagnosis Condition

2.

Malfunction Status

3.

Malfunction Time

4.

Other


Trouble Area
P282B
1.

The vehicle is being driven.

2.

There is an open or short circuit in the shift solenoid valve SLS circuit.

3.

1 second

4.

1 trip detection logic


·

Open or short in shift solenoid valve SLS circuit

·

Continuously variable transaxle assembly

·

ECM



MONITOR DESCRIPTION

This DTC indicates an open or short circuit in the shift solenoid valve SLS circuit. When there is an open or short circuit in the shift solenoid valve SLS circuit, the ECM detects the problem, illuminates the MIL and stores the DTC.

WIRING DIAGRAM

C200871E34
5.781,2.927 6.094,3.125 0.313,0.198 10 false D2 5.781,3.115 6.167,3.313 0.385,0.198 10 false ECM 5.615,1.24 6.031,1.438 0.417,0.198 10 false SLS+ 5.323,2.344 5.552,2.542 0.229,0.198 10 false 75 5.323,1.375 5.521,1.573 0.198,0.198 10 false 76 5.615,2.198 6.104,2.396 0.49,0.198 10 false SLS- 3.167,1.125 3.615,1.323 0.448,0.198 10 false SLS+ 3.625,2.344 3.854,2.542 0.229,0.198 10 false 8 3.625,1.354 3.823,1.552 0.198,0.198 10 false 3 3.167,2.083 3.531,2.281 0.365,0.198 10 false SLS- 1.469,1.729 3.094,1.927 1.625,0.198 10 false Shift Solenoid Valve SLS 1.167,2.698 1.479,2.896 0.313,0.198 10 false D67 1.167,2.896 3.302,3.26 2.135,0.365 10 false Transmission Wire (Continuously Variable Transaxle Assembly)

PROCEDURE

1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLS)
a.
C199169E76
0.979,1.698 1.719,1.229 true 1.708,0.958 0.969,0.49 true 0.583,0.375 1,0.573 0.417,0.198 10 false SLS+ 0.073,0.063 0.385,0.26 0.313,0.198 10 false *1 0.615,1.635 1.01,1.833 0.396,0.198 10 false SLS-

Disconnect the transmission wire connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 (SLS+) - 8 (SLS-) 20°C (68°F) 5.0 to 5.6 Ω
3 (SLS+) - Body ground Always 10 kΩ or higher
8 (SLS-) - Body ground Always 10 kΩ or higher


Text in Illustration
*1 Component without harness connected
(Transmission Wire)



OK

2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)

NG

5.REPLACE CONTINUOUSLY VARIABLE TRANSAXLE ASSEMBLY
2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
a.

Disconnect the ECM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
D2-75 (SLS-) - D2-76 (SLS+) 20°C (68°F) 5.0 to 5.6 Ω
D2-75 (SLS-) - Body ground Always 10 kΩ or higher
D2-76 (SLS+) - Body ground Always 10 kΩ or higher




OK

3.REPLACE ECM

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.REPLACE ECM

NEXT

4.PERFORM INITIALIZATION
5.REPLACE CONTINUOUSLY VARIABLE TRANSAXLE ASSEMBLY

NEXT

6.PERFORM INITIALIZATION