1. PRECAUTIONS AND WORK DESCRIPTION
The K112 continuously variable transaxle does not have an oil filler tube or oil level gauge. When adding fluid, add fluid through the refill hole in the transaxle case. The fluid level can be adjusted by draining excess fluid (allowing excess fluid to overflow) through the No. 1 transmission oil filler tube of the transaxle oil pan sub-assembly.
"Overflow" indicates the condition under which fluid comes out of the overflow plug hole.
When adding fluid, add the specified amount of fluid while the engine is cold. Then, warm up the engine to circulate the fluid in the continuously variable transaxle and adjust the fluid level with the engine idling at the specified fluid temperature.
The K112 continuously variable transaxle requires Toyota Genuine CVT Fluid FE.
When adjusting the fluid level, park the vehicle on level ground. Make sure that the tilt angle from the front to rear of the vehicle is within +/- 1°.
When adjusting the fluid level, turn off all electrical devices, such as the air conditioning, headlights and electric fan to reduce electrical load.
The fluid temperature shown in the text is "A/T Oil Temperature 1" displayed on the intelligent tester.
Fluid level adjustment should be performed according to the following procedure and notes.
2. WORK FLOW
The adjustment should be performed according to the procedure referenced in the work flow below.
3. BEFORE FILLING TRANSAXLE WITH FLUID
If the transaxle is hot (fluid temperature is high), wait until the fluid temperature becomes the same as the ambient temperature before starting the following procedure (recommended fluid temperature: approximately 20°C [68°F])
Lift the vehicle.
Set the vehicle on a lift so that the vehicle is kept level when it is lifted up (make sure that the tilt angle from the front to rear of the vehicle is within +/- 1°).
Remove the rear engine under cover LH.
4. PERFORM INITIAL FILLING
After performing any of the following operations, it is not necessary to perform the initial filling procedure. Proceed to the Add Specified Amount of Fluid procedure (Step 5).
| Operations that do not Require Initial Filling |
|---|
·
Disconnection of the oil cooler or oil cooler hose. ·
Repair of fluid leak, etc. ·
Installation of a new transaxle. |
Using a 6 mm hexagon socket wrench, remove the overflow plug and gasket from the continuously variable transaxle.
If fluid comes out after removing the overflow plug, wait until the fluid flow slows and only drops come out.
If fluid comes out, it is not necessary to perform the initial filling procedure. After checking the tightening torque of the No. 1 transmission oil filler tube, temporarily install the overflow plug.
Using a 6 mm hexagon socket wrench, check that the No. 1 transmission oil filler tube is tightened to the specified torque.
| *1 | No. 1 Transmission Oil Filler Tube |
If the No. 1 transmission oil filler tube is not tightened to the specified torque, the amount of fluid cannot be precisely adjusted.
To check the torque of the No. 1 transmission oil filler tube, insert the hexagon socket wrench into the overflow plug hole.
Remove the refill plug and gasket from the continuously variable transaxle.
Perform initial filling.
Add fluid to the refill hole until it flows out of the overflow plug hole.
Use Toyota Genuine CVT Fluid FE.
Wait until the fluid flow slows and only drops come out.
Temporarily install the gasket and overflow plug.
Reuse the old gasket as the overflow plug will be removed again to adjust the fluid level.
5.ADD SPECIFIED AMOUNT OF FLUID
Remove the refill plug and gasket from the continuously variable transaxle (when initial filling was not performed).
Add fluid to the refill hole using the correct amount of fluid as listed in the table below.
Refill amount differs depending on the operation that was performed.
| Operation Performed | Refill Amount |
|---|---|
·
Disconnection of the oil cooler or cooler hose. ·
Repair of fluid leak, etc. |
0.6 liters (0.6 US qts, 0.5 Imp. qts) |
| Installation of a new continuously variable transaxle (a new torque converter assembly has been installed). | 6.2 liters (6.6 US qts, 5.5 Imp. qts) |
| Installation of a new continuously variable transaxle (the old torque converter assembly has been reused). | 5.6 liters (5.9 US qts, 4.9 Imp. qts) |
·
Removal and installation of the drive shaft. ·
Removal and installation of the oil pan. |
2.1 liters (2.2 US qts, 1.8 Imp. qts) |
| Removal and installation of the torque converter assembly (a new torque converter assembly has been installed). | 3.4 liters (3.6 US qts, 3.0 Imp. qts) |
| Removal and installation of the torque converter assembly (the old torque converter assembly has been reused). | 2.9 liters (3.1 US qts, 2.6 Imp. qts) |
Temporarily install the gasket and refill plug to avoid fluid spillage.
Reuse the old gasket as the refill plug will be removed again to adjust the fluid level.
Lower the vehicle.
6.ADJUST FLUID TEMPERATURE
When using the intelligent tester:
Connect the intelligent tester to the DLC3 with the engine switch off.
Turn the engine switch on (IG) and turn the intelligent tester on.
Enter the following menus: Powertrain / Engine and ECT / Active Test / Connect the TC and TE1.
Enter the following menus: Powertrain / Engine and ECT / Data List / A/T Oil Temperature 1.
According to the display on the intelligent tester, turn on the Connect the TC and TE1 Active Test.
The indicator lights on the combination meter blink to indicate the DTC output during the Active Test.
When not using the intelligent tester:
Using SST, connect terminals 13 (TC) and 4 (CG) of the DLC3 with the engine switch off.
| *1 | Front view of DLC3 |
Depress and hold the brake pedal.
Start the engine.
Check that electrical systems such as the air conditioning system, audio system and lighting system are off.
Slowly move the shift lever from P to D, and then back to P (keep the shift lever in each position for approximately 3 seconds).
Slowly move the shift lever to circulate the fluid through each part of the continuously variable transaxle.
While observing the D shift indicator on the combination meter, move the shift lever back and forth between N and D at an interval of less than 1.5 seconds for 6 seconds or more.
Do not pause for more than 1.5 seconds.
Performing this operation will cause the vehicle to enter fluid temperature detection mode.
Check that the D shift indicator comes on for 2 seconds.
When fluid temperature detection mode is activated, the D shift indicator on the combination meter comes on for 2 seconds.
If the D shift indicator does not come on for 2 seconds, return to the step where terminals 13 (TC) and 4 (CG) are first connected and perform the procedure again.
Move the shift lever from N to P.
Release the brake pedal.
Disconnect the terminals of the DLC3.
When using the intelligent tester:
According to the display on the intelligent tester, turn off the Connect the TC and TE1 Active Test.
When not using the intelligent tester:
Remove SST from terminals 13 (TC) and 4 (CG).
Make sure that terminals 13 (TC) and 4 (CG) are not connected. If the terminals are connected, the fluid level cannot be precisely adjusted due to fluctuations in engine speed.
Disconnecting terminals 13 (TC) and 4 (CG) activates engine idle speed control mode.
In engine idle speed control mode, engine idle speed control starts when the fluid temperature reaches the specified value and the engine speed is maintained.
Even after terminals 13 (TC) and 4 (CG) are disconnected, fluid temperature detection mode remains active until the engine switch is turned off.
Adjust the fluid temperature to the normal operating temperature.
Check the fluid temperature by monitoring the D shift indicator.
In fluid temperature detection mode, the D shift indicator comes on, goes off, or blinks depending on the fluid temperature.
The fluid filling procedure should be performed when the D shift indicator is on (the fluid temperature is within the fluid level adjustment temperature range).
Adjust the fluid temperature.
If the D shift indicator is off [Below Normal Operating Temperature: 30°C (86°F) or less]: Warm up the engine with the engine idling in engine idle speed control mode until the D shift indicator turns on.
If the D shift indicator is on [Normal Operating Temperature: 30 to 40°C (86 to 104°F)]: Immediately proceed to the Adjust Fluid Level procedure (Step 7).
If the D shift indicator is blinking [Above Normal Operating Temperature: 40°C (104°F) or more]: Stop the engine and wait until the fluid temperature drops to 30°C (86°F) or less (the D shift indicator goes off). Then perform the Adjust Fluid Temperature procedure again from the beginning.
| Below Fluid Level Adjustment Temperature | Fluid Level Adjustment Temperature | Above Fluid Level Adjustment Temperature | |
|---|---|---|---|
| Fluid Temperature ("A/T Oil Temperature 1" displayed on the intelligent tester) | 30°C (86°F) or less | 30 to 40°C (86 to 104°F) | 40°C (104°F) or more |
| D Shift Indicator | Off | On | Blinks |
7.ADJUST FLUID LEVEL
Use caution while the engine is idling and the radiator fan is operating.
Lift the vehicle.
Set the vehicle on a lift so that the vehicle is kept level when it is lifted up (make sure that the tilt angle from the front to rear of the vehicle is within +/- 1°).
Using a 6 mm hexagon socket wrench, remove the overflow plug and gasket.
Be careful as the fluid coming out of the overflow plug hole is hot.
Check the amount of fluid that comes out of the overflow plug hole.
If the amount of fluid that comes out of the overflow plug hole is large, proceed to *1.
If no fluid comes out of the overflow plug hole, proceed to *2.
If only a small amount of fluid (approximately 5 cc) comes out of the overflow plug hole, then only fluid remaining in the No. 1 transmission oil filler tube has come out. This is not considered to be overflow.
*2:
If no fluid comes out of the overflow plug hole, remove the refill plug and gasket. Then add transaxle fluid through the refill hole until fluid comes out of the overflow plug hole. Wait until the fluid flow slows and only drops come out.
Use Toyota Genuine CVT Fluid FE.
*1:
If the amount of fluid that comes out of the overflow plug hole is large, wait until the fluid flow slows and only drops come out.
The fluid flow will not stop completely because the fluid continues to expand as its temperature increases.
Install a new gasket and the overflow plug.
Install a new gasket and the refill plug.
Lower the vehicle.
Turn the engine switch off.
Turning the engine switch off exits fluid temperature detection mode.
Remove the intelligent tester from the DLC3 (when using the intelligent tester).
8. AFTER FILLING TRANSAXLE
Lift the vehicle.
Clean each part.
Check for fluid leaks.
Install the rear engine under cover LH.
Lower the vehicle.