Home › Engine / Hybrid System › 2GR-FE STARTING › STARTER RELAY
RM24M0E _51 Engine / Hybrid System _059574 2GR-FE STARTING _0292069 STARTER RELAY G

2GR-FE STARTING  STARTER RELAY  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 1.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

CAUTION:

Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to prevent airbag and seat belt pretensioner activation.


NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected (See page General>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION).


Hide 2.REMOVE STARTER RELAY (Marking: ST)

a.

Remove the starter relay from the engine room No. 1 relay block.


Hide 28300 3.INSPECT STARTER RELAY

a.
B448600E02
2.021,0.656 1.76,0.323 false 2.625,0.76 2.885,0.396 false 2.458,1.135 3.01,1.135 false 2.469,1.635 3.021,1.635 false 0.24,0.771 0.396,0.969 0.156,0.198 10 false 5 0.24,1.313 0.396,1.51 0.156,0.198 10 false 1 1.188,1.323 1.344,1.521 0.156,0.198 10 false 2 3.094,1.042 3.25,1.24 0.156,0.198 10 false 5 1.177,0.771 1.385,0.969 0.208,0.198 10 false 3 3.094,1.552 3.302,1.75 0.208,0.198 10 false 3 1.667,0.167 1.823,0.365 0.156,0.198 10 false 1 2.927,0.229 3.083,0.427 0.156,0.198 10 false 2

Measure the resistance of the relay.

Standard resistance:
Tester Connection Specified Condition
3 - 5 10 kΩ or higher
3 - 5 Below 1 Ω
(when battery voltage is applied to terminals 1 and 2)


If the resistance is not as specified, replace the relay.


Hide 4.INSTALL STARTER RELAY

Hide 5.CONNECT CABLE TO NEGATIVE BATTERY TERMINAL