Home › Engine / Hybrid System › 2AZ-FE STARTING › STARTER RELAY
RM24M0E _51 Engine / Hybrid System _059575 2AZ-FE STARTING _0292074 STARTER RELAY G

2AZ-FE STARTING  STARTER RELAY  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 1.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

CAUTION:

Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to prevent airbag and seat belt pretensioner activation.


Hide 2.REMOVE STARTER RELAY (Marking: ST)

a.

Remove the starter relay from the engine room No. 1 relay block.


Hide 28300 3.INSPECT STARTER RELAY

a.
B448600E02
2.021,0.656 1.76,0.323 false 2.625,0.76 2.885,0.396 false 2.458,1.135 3.01,1.135 false 2.469,1.635 3.021,1.635 false 0.24,0.771 0.396,0.969 0.156,0.198 10 false 5 0.24,1.313 0.396,1.51 0.156,0.198 10 false 1 1.188,1.323 1.344,1.521 0.156,0.198 10 false 2 3.094,1.042 3.25,1.24 0.156,0.198 10 false 5 1.177,0.771 1.385,0.969 0.208,0.198 10 false 3 3.094,1.552 3.302,1.75 0.208,0.198 10 false 3 1.667,0.167 1.823,0.365 0.156,0.198 10 false 1 2.927,0.229 3.083,0.427 0.156,0.198 10 false 2

Measure the resistance of the relay.

Standard resistance:
Tester Connection Specified Condition
3 - 5 10 kΩ or higher
3 - 5 Below 1 Ω
(when battery voltage is applied to terminals 1 and 2)


If the resistance is not as specified, replace the relay.


Hide 4.INSTALL STARTER RELAY

Hide 5.CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

Hide 6.PERFORM INITIALIZATION

a.

Perform initialization (see page General>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION).

NOTICE:

Certain systems need to be initialized after disconnecting and reconnecting the cable from the negative (-) battery terminal.