The ATF temperature sensor converts the automatic transaxle fluid (ATF) temperature into a resistance value for use by the ECM.
The ECM applies a voltage to the temperature sensor through terminal THO1 of the ECM.
The sensor resistance changes with the ATF temperature. As the temperature rises, the sensor resistance decreases.
One terminal of the sensor is grounded so that the sensor resistance and voltage decrease as the temperature rises.
The ECM calculates the ATF temperature based on the voltage signal.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P0711 | Either condition is met (2 trip detection logic):
·
Certain monitor enabling conditions are met and the ATF temperature is below 20°C (68°F). ·
Certain monitor enabling conditions are met and the ATF temperature is 110°C (230°F) or higher. |
·
Open or short in No. 1 ATF temperature sensor circuit ·
No. 1 ATF temperature sensor ·
ECM |
This DTC indicates that there is a problem with output signals from the automatic transmission fluid (ATF) temperature sensor (TFT sensor) and that the sensor itself is defective. The ATF temperature sensor converts the ATF temperature into an electrical resistance value. Based on the resistance, the ECM determines the ATF temperature and detects an open or short in the ATF temperature circuit or a fault of the ATF temperature sensor.
After running the vehicle for a certain period, the ATF temperature should increase. If the ATF temperature is below 20°C (68°F) after running the vehicle for a certain period, the ECM interprets this as a fault, and turns on the MIL.
Refer to DTC P0710 (see page Drivetrain>U241E (AUTOMATIC TRANSMISSION / TRANSAXLE)>AUTOMATIC TRANSAXLE SYSTEM>P0710).
Using the intelligent tester's Data List allows switch, sensor, actuator and other item values to be read without removing any parts. Reading the Data List early in troubleshooting is one way to save time.
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Warm up the engine.
Turn the ignition switch off.
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the tester ON.
Enter the following menus: Powertrain / Engine and ECT / Data List.
Follow the instructions on the tester and read the Data List.
| Item | Measurement Item/
Range (Display) |
Normal Condition | Diagnostic Note |
|---|---|---|---|
| A/T Oil Temperature 1 | ATF temperature sensor value/
Min.: -40°C (-40°F) Max.: 215°C (419°F) |
·
After stall test: Approximately 80°C (176°F) ·
Equal to ambient temperature while engine is cold |
If value is -40°C (-40°F) or "150°C (302°F) or more", ATF temperature sensor circuit is open or short circuited |
When DTC P0712 is output and the tester output is 150°C (302°F) or more, there is a short circuit.
When DTC P0713 is output and the tester output is -40°C (-40°F), there is an open circuit.
Measure the resistance between terminal THO1 (THO) and the body ground.
| Temperature Displayed | Malfunction |
|---|---|
| -40°C (-40°F) | Open circuit |
| 150°C (302°F) or more | Short circuit |
If a circuit related to the ATF temperature sensor becomes open, P0713 is set in approximately 0.5 seconds.
It is not necessary to inspect the circuit when P0711 is set.
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the tester ON.
Enter the following menus: Powertrain / Engine and ECT / DTC / Current or Pending.
Read the DTCs using the tester.
| Display (DTC output) | Proceed to |
|---|---|
| Only P0711 is output | A |
| P0711 and other DTCs are output | B |
If any other codes besides P0711 are output, perform troubleshooting for those DTCs first.
A
B
Automatic transaxle fluid level is correct.
OK
NG