Home › Drivetrain › U241E (AUTOMATIC TRANSMISSION / TRANSAXLE) › SPEED SENSOR
RM24M0E _52 Drivetrain _059578 U241E AUTOMATIC TRANSMISSION / TRANSAXLE _0292108 SPEED SENSOR A

U241E AUTOMATIC TRANSMISSION / TRANSAXLE  SPEED SENSOR  INSTALLATION  


PROCEDURE

Hide 89413B 1.INSTALL SPEED SENSOR NC

C132986

a.

Coat a new O-ring with ATF.


b.

Install the O-ring to the sensor.


c.

Install the sensor with the bolt.

Torque:
8.8 N*m (90 kgf*cm, 77 in.*lbf)


d.

Connect the sensor connector.


Hide 89413B 2.INSTALL SPEED SENSOR NT

C132987

a.

Coat a new O-ring with ATF.


b.

Install the O-ring to the sensor.


c.

Install the sensor with the bolt.

Torque:
8.8 N*m (90 kgf*cm, 78 in.*lbf)


d.

Connect the sensor connector.


Hide 3.INSTALL BATTERY

a.

Install the battery bracket reinforcement with the 2 bolts.

Torque:
19 N*m (194 kgf*cm, 14 ft.*lbf)


b.

Install the battery carrier with the 4 bolts.

Torque:
19 N*m (194 kgf*cm, 14 ft.*lbf)


c.

Insert the No. 2 air cleaner inlet to the bracket with the bolt.

Torque:
5.0 N*m (51 kgf*cm, 44 in.*lbf)


d.

Attach the 2 wire harness clamps.


e.

Install the battery tray.


f.

Install the battery with the battery clamp.

Torque:
5.0 N*m (51 kgf*cm, 44 in.*lbf)

for nut



Hide 4.CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

Hide 5.PERFORM INITIALIZATION

a.

Perform initialization (see page General>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION).

NOTICE:

Certain systems need to be initialized after disconnecting and reconnecting the cable from the negative (-) battery terminal.