U660E AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSAXLE SYSTEM  P2716  Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)  


DESCRIPTION

Refer to DTC P2714 (See page Drivetrain>U660E (AUTOMATIC TRANSMISSION / TRANSAXLE)>AUTOMATIC TRANSAXLE SYSTEM>P2714).

DTC No. DTC Detection Condition Trouble Area
P2716 Open or short is detected in shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detection logic).
·

Open or short in shift solenoid valve SLT circuit

·

Shift solenoid valve SLT

·

TCM



MONITOR DESCRIPTION

When an open or short in the linear solenoid valve (SLT) circuit is detected, the TCM interprets this as a fault. The TCM will turn on the MIL and store the DTC.

WIRING DIAGRAM

C133261E76
5.635,0.531 6,0.865 0.365,0.333 10 false TCM 2.26,3.875 3.635,4.302 1.375,0.427 10 false Transaxle Assembly 5.083,1.802 5.625,1.969 0.542,0.167 10 false SLT+ 5.813,1.073 6.354,1.24 0.542,0.167 10 false +B 5.083,3.208 5.625,3.375 0.542,0.167 10 false SLT- 1.594,2.344 3.646,2.729 2.052,0.385 10 false Shift Solenoid Valve SLT 4.802,1.552 4.969,1.729 0.167,0.177 10 false 12 4.865,2.927 5.021,3.104 0.156,0.177 10 false 7 1.406,2.688 1.563,2.865 0.156,0.177 10 false 1 1.417,2.01 1.573,2.188 0.156,0.177 10 false 2

PROCEDURE

1.INSPECT TRANSMISSION WIRE (SLT)
a.
C133212E06
2.329,1.064 2.683,1.213 0.354,0.149 10 SLT+ 2.266,0.345 2.597,0.494 0.331,0.149 10 SLT- 1.783,0.715 2.25,0.45 false 1.904,0.957 2.313,1.129 false

Remove the TCM from the transaxle.


b.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Specified Condition
7 (SLT-) - 12 (SLT+) 5.0 to 5.6 Ω
(at 20°C (68°F))



c.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Specified Condition
7 (SLT-) - Body ground 10 kΩ or higher
12 (SLT+) - Body ground 10 kΩ or higher




NG

2.INSPECT SHIFT SOLENOID VALVE SLT

OK

REPLACE TCM

2.INSPECT SHIFT SOLENOID VALVE SLT
a.
U190020E02
0.052,0.052 2.063,0.375 2.01,0.323 10 false Shift Solenoid Valve SLT: 0.583,0.51 0.729,0.719 0.146,0.208 10 false 1 2.521,0.448 2.667,0.656 0.146,0.208 10 false 2 2.698,2.625 2.844,2.833 0.146,0.208 10 false 2 0.646,2.771 0.792,2.979 0.146,0.208 10 false 1 1.167,4.208 1.417,4.438 0.25,0.229 10 false (-) 1.969,4.208 2.219,4.438 0.25,0.229 10 false (+)

Remove the shift solenoid valve SLT.


b.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Specified Condition
1 - 2 5.0 to 5.6 Ω
(at 20°C (68°F))



c.

Connect a positive (+) lead through a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

OK:

The solenoid makes an operating sound.




OK

REPLACE TRANSMISSION WIRE

NG

REPLACE SHIFT SOLENOID VALVE SLT