Home › Drivetrain › U660E (AUTOMATIC TRANSMISSION / TRANSAXLE) › AUTOMATIC TRANSAXLE SYSTEM
RM24M0E _52 Drivetrain _059579 U660E AUTOMATIC TRANSMISSION / TRANSAXLE _0292111 AUTOMATIC TRANSAXLE SYSTEM C

U660E AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSAXLE SYSTEM  P0748  Pressure Control Solenoid "A" Electrical (Shift Solenoid Valve SL1)  


DESCRIPTION

Shifting from 1st to 6th is performed in combination with "ON" and "OFF" operation of the shift solenoid valves SL1, SL2, SL3, SL4 and SL which is controlled by the TCM. If an open or short circuit occurs in any of the shift solenoid valves, the TCM controls the remaining normal shift solenoid valves to allow the vehicle to be operated smoothly (See page Drivetrain>U660E (AUTOMATIC TRANSMISSION / TRANSAXLE)>AUTOMATIC TRANSAXLE SYSTEM>FAIL-SAFE CHART).

DTC No. DTC Detection Condition Trouble Area
P0748 The TCM checks for an open or short in the shift solenoid valve SL1 circuit while driving and shifting between 4th and 5th gears. (1-trip detection logic)
·

Output signal duty equals 100%.

(NOTE: SL1 output signal duty is less than 100% under normal condition.)


·

Open or short in shift solenoid valve SL1 circuit

·

Shift solenoid valve SL1

·

TCM



MONITOR DESCRIPTION

This DTC indicates an open or short in the shift solenoid valve SL1 circuit. The TCM causes gear shifts to occur by turning the shift solenoid valves on or off. When there is an open or short circuit in any shift solenoid valve circuit, the TCM detects the problem, illuminates the MIL and stores the DTC. The TCM also performs the fail-safe function and turns the other normal shift solenoid valves on or off. (In case of an open or short circuit, the TCM stops sending current to the circuit.)

While driving and shifting between 4th and 5th gears, if the TCM detects an open or short in the shift solenoid valve SL1 circuit, the TCM determines there is a malfunction (See page Drivetrain>U660E (AUTOMATIC TRANSMISSION / TRANSAXLE)>AUTOMATIC TRANSAXLE SYSTEM>FAIL-SAFE CHART).

WIRING DIAGRAM

C133261E73
5.625,0.531 5.99,0.865 0.365,0.333 10 false TCM 1.99,3.854 3.365,4.281 1.375,0.427 10 false Transaxle Assembly 5.063,1.573 5.604,1.74 0.542,0.167 10 false SL1+ 5.813,1.083 6.354,1.25 0.542,0.167 10 false +B 5.063,2.948 5.604,3.115 0.542,0.167 10 false SL1- 1.563,2.344 3.615,2.729 2.052,0.385 10 false Shift Solenoid Valve SL1 4.792,1.542 4.958,1.719 0.167,0.177 10 false 14 4.792,2.938 4.958,3.115 0.167,0.177 10 false 13 1.396,2.667 1.563,2.844 0.167,0.177 10 false 1 1.406,2.021 1.573,2.198 0.167,0.177 10 false 2

CAUTION / NOTICE / HINT

HINT:

The shift solenoid valve SL1 is turned on or off automatically when the shift lever is in the D position:

TCM command gearshift 1st 2nd 3rd 4th 5th 6th
Shift solenoid valve SL1 ON ON ON ON OFF OFF


PROCEDURE

1.INSPECT TRANSMISSION WIRE (SL1)
a.
C133212E91
1.625,0.875 1.031,0.375 true 1.76,0.875 2.271,0.365 true 0.677,0.281 1.031,0.427 0.354,0.146 10 false SL1+ 2.302,0.281 2.635,0.427 0.333,0.146 10 false SL1-

Remove the TCM from the transaxle.


b.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Specified Condition
14 (SL1+) - 13 (SL1-) 5.0 to 5.6 Ω
(at 20°C (68°F))



c.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Check for short:
Tester Connection Specified Condition
14 (SL1+) - Body ground 10 kΩ or higher
13 (SL1-) - Body ground 10 kΩ or higher




NG

2.INSPECT SHIFT SOLENOID VALVE SL1

OK

REPLACE TCM

2.INSPECT SHIFT SOLENOID VALVE SL1
a.

Remove the shift solenoid valve SL1.


G102540E01
1.76,3.115 2.469,2.76 false 1.49,3.115 0.781,2.802 false 1.76,0.906 2.469,0.552 false 1.479,0.896 0.771,0.583 false 0.115,0.063 1.938,0.385 1.823,0.323 10 false Shift Solenoid Valve SL1: 0.625,0.479 0.938,0.677 0.313,0.198 10 false 1 2.542,0.458 2.854,0.656 0.313,0.198 10 false 2 1.198,4.167 1.51,4.365 0.313,0.198 10 false (-) 1.917,4.177 2.229,4.375 0.313,0.198 10 false (+) 0.635,2.698 0.948,2.896 0.313,0.198 10 false 1 2.531,2.656 2.844,2.854 0.313,0.198 10 false 2

b.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Specified Condition
1 - 2 5.0 to 5.6 Ω
(at 20°C (68°F))



c.

Connect a positive (+) lead through a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

OK:

The solenoid makes an operating sound.




OK

REPLACE TRANSMISSION WIRE

NG

REPLACE SHIFT SOLENOID VALVE SL1