Shifting from 1st to 6th is performed in combination with "ON" and "OFF" operation of the shift solenoid valves SL1, SL2, SL3, SL4 and SL which is controlled by the TCM. If an open or short circuit occurs in any of the shift solenoid valves, the TCM controls the remaining normal shift solenoid valves to allow the vehicle to be operated smoothly (See page Drivetrain>U660E (AUTOMATIC TRANSMISSION / TRANSAXLE)>AUTOMATIC TRANSAXLE SYSTEM>FAIL-SAFE CHART).
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P0778 | The TCM checks for an open or short in the shift solenoid valve SL2 circuit while driving and shifting gears. (1-trip detection logic)
·
Output signal duty equals to 100%. (NOTE: SL2 output signal duty is less than 100% under normal condition.) |
·
Open or short in shift solenoid valve SL2 circuit ·
Shift solenoid valve SL2 ·
TCM |
This DTC indicates an open or short in the shift solenoid valve SL2 circuit. The TCM commands gear shifts by turning the shift solenoid valves on or off. When there is an open or short circuit in any of the shift solenoid valve circuits, the TCM detects the problem, illuminates the MIL and stores the DTC. The TCM also performs the fail-safe function and turns the other normal shift solenoid valves on or off. (In case of an open or short circuit, the TCM stops sending current to the circuit.)
While driving and shifting gears, if the TCM detects an open or short in the shift solenoid valve SL2 circuit, the TCM determines there is a malfunction (See page Drivetrain>U660E (AUTOMATIC TRANSMISSION / TRANSAXLE)>AUTOMATIC TRANSAXLE SYSTEM>FAIL-SAFE CHART).
The shift solenoid valve SL2 is turned on or off automatically when the shift lever is in the D position:
| TCM command gearshift | 1st | 2nd | 3rd | 4th | 5th | 6th |
| Shift solenoid valve SL2 | OFF | OFF | OFF | ON | ON | ON |
Remove the TCM from the transaxle.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
|---|---|
| 9 (SL2+) - 8 (SL2-) | 5.0 to 5.6 Ω
(at 20°C (68°F)) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
|---|---|
| 9 (SL2+) - Body ground | 10 kΩ or higher |
| 8 (SL2-) - Body ground | 10 kΩ or higher |
NG
OK
Remove the shift solenoid valve SL2.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
|---|---|
| 1 - 2 | 5.0 to 5.6 Ω
(at 20°C (68°F)) |
Connect a positive (+) lead through a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
The solenoid makes an operating sound.
OK
NG