Home › Drivetrain › U660E (AUTOMATIC TRANSMISSION / TRANSAXLE) › AUTOMATIC TRANSAXLE SYSTEM
RM24M0E _52 Drivetrain _059579 U660E AUTOMATIC TRANSMISSION / TRANSAXLE _0292111 AUTOMATIC TRANSAXLE SYSTEM C

U660E AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSAXLE SYSTEM  P2810  Pressure Control Solenoid "G" Electrical (Shift Solenoid Valve SL4)  


DESCRIPTION

Shifting gears from 1st through 5th is performed in combination with "ON" and "OFF" operation of the shift solenoid valves SL1, SL2, SL3 and SL4 which are controlled by the TCM. If an open or short circuit occurs in either of the shift solenoid valves, the TCM controls the remaining normal shift solenoid valves to allow the vehicle to be operated smoothly (Fail safe function).

DTC No. DTC Detection Condition Trouble Area
P2810 The TCM checks for an open or short in the shift solenoid valve SL4 circuit while driving and shifting gears.
(1-trip detection logic)
·

Output signal duty equals 100%.

(NOTE: SL4 output signal duty is less than 100% under normal condition.)


·

Open or short in shift solenoid valve SL4 circuit

·

Shift solenoid valve SL4

·

TCM



MONITOR DESCRIPTION

The TCM commands gear shifts by turning the shift solenoid valves on or off. When there is an open or short circuit in any shift solenoid valve circuit, the TCM detects the problem, illuminates the MIL and stores the DTC. And the TCM performs the fail-safe function and turns the other normal shift solenoid valves on or off. (In case of an open or short circuit, the TCM stops sending current to the circuit.)

(See page Drivetrain>U660E (AUTOMATIC TRANSMISSION / TRANSAXLE)>AUTOMATIC TRANSAXLE SYSTEM>FAIL-SAFE CHART)

WIRING DIAGRAM

C133261E71
5.635,0.51 6,0.844 0.365,0.333 10 false TCM 2.156,3.854 3.531,4.281 1.375,0.427 10 false Transaxle Assembly 5.063,1.813 5.604,1.979 0.542,0.167 10 false SL4+ 5.792,1.083 6.333,1.25 0.542,0.167 10 false +B 5.073,3.188 5.615,3.354 0.542,0.167 10 false SL4- 1.583,2.354 3.635,2.74 2.052,0.385 10 false Shift Solenoid Valve SL4 4.802,1.573 4.969,1.75 0.167,0.177 10 false 22 4.802,2.938 4.969,3.115 0.167,0.177 10 false 21

PROCEDURE

1.INSPECT TRANSMISSION WIRE (SL4 CIRCUIT)
a.
C133212E08
0.622,0.338 0.976,0.487 0.354,0.149 10 SL4+ 2.26,0.355 2.591,0.504 0.331,0.149 10 SL4- 1.404,1.046 1.039,0.463 false 1.541,1.035 2.242,0.454 false

Remove the TCM from the transaxle.


b.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Specified Condition
22 (SL4+) - 21 (SL4-) 5.0 to 5.6 Ω
(at 20°C (68°F))



c.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Specified Condition
22 (SL4+) - Body ground 10 kΩ or higher
21 (SL4-) - Body ground 10 kΩ or higher




NG

2.INSPECT SHIFT SOLENOID VALVE SL4

OK

REPLACE TCM

2.INSPECT SHIFT SOLENOID VALVE SL4
a.
G102540E05
1.76,3.115 2.469,2.76 false 1.49,3.115 0.781,2.802 false 1.76,0.906 2.51,0.656 false 1.448,0.896 0.74,0.688 false 0.115,0.063 1.938,0.385 1.823,0.323 10 false Shift Solenoid Valve SL4: 0.573,0.583 0.885,0.781 0.313,0.198 10 false 1 2.573,0.552 2.885,0.75 0.313,0.198 10 false 2 1.198,4.167 1.51,4.365 0.313,0.198 10 false (-) 1.917,4.177 2.229,4.375 0.313,0.198 10 false (+) 0.635,2.698 0.948,2.896 0.313,0.198 10 false 1 2.531,2.656 2.844,2.854 0.313,0.198 10 false 2

Remove the shift solenoid valve SL4.


b.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Specified Condition
1 - 2 5.0 to 5.6 Ω
(at 20°C (68°F))



c.

Connect a positive (+) lead through a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

OK:

The solenoid makes an operating sound.




OK

REPLACE TRANSMISSION WIRE

NG

REPLACE SHIFT SOLENOID VALVE SL4