An ultrasonic sensor consists of a sensor portion that transmits and receives ultrasonic waves and a preamplifier that amplifies them. The ultrasonic sensor outputs the ultrasonic waves and sends the received signals to the clearance warning ECU assembly.
for Type A
for Type B
Choose the model to be inspected.
| Result | Proceed to |
|---|---|
| for Type A | A |
| for Type B | B |
A
B
Remove the No. 1 ultrasonic sensor (back sensor RH) (See page Audio / Visual / Telematics>PARK ASSIST / MONITORING>ULTRASONIC SENSOR(for Rear Side)>REMOVAL).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (BI) - 5 (EI) | Always | 10 kΩ or higher |
| 1 (BI) - 2 (BO) | Always | 10 kΩ or higher |
| 3 (SI) - 4 (SO) | Always | Below 1 Ω |
| 5 (EI) - 6 (EO) | Always | Below 1 Ω |
| *a | Component without harness connected
(No. 1 Ultrasonic Sensor (Back Sensor RH)) |
OK
NG
(See pageAudio / Visual / Telematics>PARK ASSIST / MONITORING>ULTRASONIC SENSOR(for Rear Side)>REMOVAL)
Disconnect the R8 and R9 No. 1 ultrasonic sensor connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| R8-1 (BI) - R9-2 (BO) | Always | Below 1 Ω |
| R8-3 (SI) - R9-4 (SO) | Always | Below 1 Ω |
| R8-5 (EI) - R9-6 (EO) | Always | Below 1 Ω |
| R8-1 (BI) - Body ground | Always | 10 kΩ or higher |
| R8-3 (SI) - Body ground | Always | 10 kΩ or higher |
| R8-5 (EI) - Body ground | Always | 10 kΩ or higher |
OK
NG
Remove the No. 1 ultrasonic sensor (back sensor RH) (See page Audio / Visual / Telematics>PARK ASSIST / MONITORING>ULTRASONIC SENSOR(for Rear Side)>REMOVAL).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (BI) - 5 (EI) | Always | 10 kΩ or higher |
| 1 (BI) - 2 (BO) | Always | 10 kΩ or higher |
| 3 (SI) - 4 (SO) | Always | Below 1 Ω |
| 5 (EI) - 6 (EO) | Always | Below 1 Ω |
| *a | Component without harness connected
(No. 1 Ultrasonic Sensor (Back Sensor RH)) |
OK
NG
(See pageAudio / Visual / Telematics>PARK ASSIST / MONITORING>ULTRASONIC SENSOR(for Rear Side)>REMOVAL)
Disconnect the R12 and R13 No. 1 ultrasonic sensor connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| R12-1 (BI) - R13-2 (BO) | Always | Below 1 Ω |
| R12-3 (SI) - R13-4 (SO) | Always | Below 1 Ω |
| R12-5 (EI) - R13-6 (EO) | Always | Below 1 Ω |
| R12-1 (BI) - Body ground | Always | 10 kΩ or higher |
| R12-3 (SI) - Body ground | Always | 10 kΩ or higher |
| R12-5 (EI) - Body ground | Always | 10 kΩ or higher |
OK
NG